These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

135 related articles for article (PubMed ID: 31410750)

  • 1. The Great View Forward: The Use of a Colonoscope for Distal Duodenal Stent Placement.
    Minervini A; Lauro A; Pagano N; Vaccari S; D'Andrea V; Marino IR; Cervellera M; Tonini V
    Dig Dis Sci; 2019 Sep; 64(9):2445-2448. PubMed ID: 31410750
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Feasibility of self-expandable metal stent placement with side-viewing endoscope for malignant distal duodenal obstruction.
    Park JM; Min BH; Lee SH; Chung KH; Lee JM; Song BJ; Lee JK; Ryu JK; Kim YT
    Dig Dis Sci; 2015 Feb; 60(2):524-30. PubMed ID: 25185660
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Use of a colonoscope for distal duodenal stent placement in patients with malignant obstruction.
    Jeurnink SM; Repici A; Luigiano C; Pagano N; Kuipers EJ; Siersema PD
    Surg Endosc; 2009 Mar; 23(3):562-7. PubMed ID: 18389314
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Side-viewing endoscope for colonic self-expandable metal stenting in patients with malignant colonic obstruction.
    Cennamo V; Fuccio L; Laterza L; Ceroni L; Eusebi LH; Fabbri C; Bazzoli F
    Eur J Gastroenterol Hepatol; 2009 May; 21(5):585-6. PubMed ID: 19282771
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Temporary placement of a covered duodenal stent can avoid riskier anterograde biliary drainage when ERCP for obstructive jaundice fails due to duodenal invasion.
    Goutorbe F; Rouquette O; Mulliez A; Scanzi J; Goutte M; Dapoigny M; Abergel A; Poincloux L
    Surg Endosc; 2017 Feb; 31(2):625-631. PubMed ID: 27324333
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Duodenal stent placement for duodenal obstruction caused by pancreatic cancer associated with annular pancreas.
    Ogura T; Masuda D; Kurisu Y; Imoto A; Takii M; Uchiyama K; Higuchi K
    Gastrointest Endosc; 2014 Sep; 80(3):530-1. PubMed ID: 24890427
    [No Abstract]   [Full Text] [Related]  

  • 7. Effectiveness of combined biliary and duodenal stenting in patients with malignant biliary and duodenal obstruction.
    Kim KO; Kim TN; Lee HC
    Scand J Gastroenterol; 2012 Sep; 47(8-9):962-7. PubMed ID: 22571283
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Percutaneous Transhepatic Self-expanding Metallic Stent Placement for the Treatment of Malignant Afferent Loop Obstruction.
    Jinno N; Naitoh I; Nagura Y; Fujioka K; Mizuno Y; Momose J; Ooyama M; Hayashi K; Miyaki T; Nakamura M; Joh T
    Intern Med; 2018 Feb; 57(3):333-337. PubMed ID: 29093418
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Single-session double-stent placement in concomitant malignant biliary and duodenal obstruction with a cautery-tipped lumen apposing metal stent.
    Anderloni A; Buda A; Carrara S; Di Leo M; Fugazza A; Maselli R; Repici A
    Endoscopy; 2016 0; 48(S 01):E321-E322. PubMed ID: 27706541
    [No Abstract]   [Full Text] [Related]  

  • 10. Biliary stenting is not a prerequisite to endoscopic placement of duodenal covered self-expandable metal stents.
    Poincloux L; Goutorbe F; Rouquette O; Mulliez A; Goutte M; Bommelaer G; Abergel A
    Surg Endosc; 2016 Feb; 30(2):437-445. PubMed ID: 25894447
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Endoscopic treatment of perforated duodenal ulcer using a partially polyurethane-covered self-expandable nitinol stent: A case report.
    Yartsev P; Kirsanov I; Teterin Y; Dmitriev I; Lebedev A; Kazakova V
    Asian J Endosc Surg; 2020 Jan; 13(1):103-106. PubMed ID: 30843334
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparison between uncovered and covered self-expandable metal stent placement in malignant duodenal obstruction.
    Kim JW; Jeong JB; Lee KL; Kim BG; Ahn DW; Lee JK; Kim SH
    World J Gastroenterol; 2015 Feb; 21(5):1580-7. PubMed ID: 25663777
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Combined use of single-balloon enteroscope and colonoscope for self-expandable metal stent placement in patients with malignant small intestinal obstruction: a single-center comparative clinical observation.
    Zhang YF; Ning SB; Li BR; Zhang J; Li J; Tang J; Zhu M; Jin XW; Zhao Q; Mao GP
    J Huazhong Univ Sci Technolog Med Sci; 2017 Jun; 37(3):357-361. PubMed ID: 28585148
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Long-term outcome of biliary and duodenal stents in palliative treatment of patients with unresectable adenocarcinoma of the head of pancreas.
    Maire F; Hammel P; Ponsot P; Aubert A; O'Toole D; Hentic O; Levy P; Ruszniewski P
    Am J Gastroenterol; 2006 Apr; 101(4):735-42. PubMed ID: 16635221
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Endoscopic trimming of metallic stents with the use of argon plasma.
    Christiaens P; Decock S; Buchel O; Bulté K; Moons V; D'Haens G; Van Olmen G
    Gastrointest Endosc; 2008 Feb; 67(2):369-71. PubMed ID: 18226706
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Preliminary study of enteroscopy-guided, self-expandable metal stent placement for malignant small bowel obstruction.
    Lee H; Park JC; Shin SK; Lee SK; Lee YC
    J Gastroenterol Hepatol; 2012 Jul; 27(7):1181-6. PubMed ID: 22414138
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Cautery-Tipped Lumen Apposing Metal Stent Placement Through the Mesh of an Indwelling Duodenal Self-Expanding Metal Stent.
    Anderloni A; Fugazza A; Auriemma F; Maia L; Maselli R; Troncone E; DʼAmico F; Repici A
    Am J Gastroenterol; 2018 May; 113(5):644. PubMed ID: 29681628
    [No Abstract]   [Full Text] [Related]  

  • 18. Saline with methylene blue-assisted endoscopic ultrasound-guided gastrojejunostomy using a double-flared fully covered metal stent.
    Wang G; Liu X; Wang S; Ge N; Guo J; Sun S
    Endoscopy; 2018 Jan; 50(1):E17-E19. PubMed ID: 29069704
    [No Abstract]   [Full Text] [Related]  

  • 19. [Palliative endoscopic treatment of malignant duodenal stenosis by metal prosthesis].
    Dumas R; Demarquay JF; Caroli-Bosc FX; Paolini O; Guenenna D; Peten EP; Delmont JP; Rampal P
    Gastroenterol Clin Biol; 2000; 24(8-9):714-8. PubMed ID: 11011246
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Proper placement of colorectal self-expandable metal stents with the help of a thin colonoscope - a video vignette.
    Lamazza A; Fiori E; Schillaci A; Sterpetti AV
    Colorectal Dis; 2018 Apr; 20(4):356-357. PubMed ID: 29352563
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 7.