These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

389 related articles for article (PubMed ID: 31423575)

  • 21. Postoperative outcomes following pediatric intracranial electrode monitoring: A case for stereoelectroencephalography (SEEG).
    Kim LH; Parker JJ; Ho AL; Pendharkar AV; Sussman ES; Halpern CH; Porter B; Grant GA
    Epilepsy Behav; 2020 Mar; 104(Pt A):106905. PubMed ID: 32028127
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Stereoelectroencephalography following subdural grid placement for difficult to localize epilepsy.
    Vadera S; Mullin J; Bulacio J; Najm I; Bingaman W; Gonzalez-Martinez J
    Neurosurgery; 2013 May; 72(5):723-9; discussion 729. PubMed ID: 23313979
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Safety and efficacy of stereoelectroencephalography in pediatric focal epilepsy: a single-center experience.
    Goldstein HE; Youngerman BE; Shao B; Akman CI; Mandel AM; McBrian DK; Riviello JJ; Sheth SA; McKhann GM; Feldstein NA
    J Neurosurg Pediatr; 2018 Oct; 22(4):444-452. PubMed ID: 30028270
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Neuropsychological outcomes after epilepsy surgery: A comparison of stereo electroencephalography and subdural electrodes.
    Arya R; Frink C; Kargol C; Byars AW; Huddleston D; Diedenhofer DB; Aungaroon G; Ervin B; Horn PS; Ihnen SKZ; Tenney JR; Kremer K; Fong S; Lin N; Liu W; Arthur TM; Skoch J; Leach JL; Mangano FT; Glauser TA; Greiner HM; Holland KD
    Eur J Neurol; 2023 Oct; 30(10):2986-2998. PubMed ID: 37329329
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Localization yield and seizure outcome in patients undergoing bilateral SEEG exploration.
    Steriade C; Martins W; Bulacio J; Morita-Sherman ME; Nair D; Gupta A; Bingaman W; Gonzalez-Martinez J; Najm I; Jehi L
    Epilepsia; 2019 Jan; 60(1):107-120. PubMed ID: 30588603
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Single-center cost comparison analysis of stereoelectroencephalography with subdural grid and strip implantation.
    Salehi A; Yang PH; Smyth MD
    J Neurosurg Pediatr; 2022 May; 29(5):568-574. PubMed ID: 35180694
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Robot-assisted stereoencephalography vs subdural electrodes in the evaluation of temporal lobe epilepsy.
    Gorbachuk M; Machetanz K; Weinbrenner E; Grimm F; Wuttke TV; Wang S; Ethofer S; Tatagiba M; Rona S; Honegger J; Naros G
    Epilepsia Open; 2023 Sep; 8(3):888-897. PubMed ID: 37149851
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Frameless robot-assisted stereoelectroencephalography in children: technical aspects and comparison with Talairach frame technique.
    Abel TJ; Varela Osorio R; Amorim-Leite R; Mathieu F; Kahane P; Minotti L; Hoffmann D; Chabardes S
    J Neurosurg Pediatr; 2018 Jul; 22(1):37-46. PubMed ID: 29676681
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Depth versus surface: A critical review of subdural and depth electrodes in intracranial electroencephalographic studies.
    Wu S; Issa NP; Rose SL; Haider HA; Nordli DR; Towle VL; Warnke PC; Tao JX
    Epilepsia; 2024 Jul; 65(7):1868-1878. PubMed ID: 38722693
    [TBL] [Abstract][Full Text] [Related]  

  • 30. The stereotactic approach for mapping epileptic networks: a prospective study of 200 patients.
    Serletis D; Bulacio J; Bingaman W; Najm I; González-Martínez J
    J Neurosurg; 2014 Nov; 121(5):1239-46. PubMed ID: 25148007
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Magnetic resonance-guided laser interstitial thermal therapy versus stereoelectroencephalography-guided radiofrequency thermocoagulation for drug-resistant epilepsy: A systematic review and meta-analysis.
    Wang Y; Xu J; Liu T; Chen F; Chen S; Xie Z; Fang T; Liang S
    Epilepsy Res; 2020 Oct; 166():106397. PubMed ID: 32590289
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Outcome of stereo-electroencephalography with single-unit recording in drug-refractory epilepsy.
    Nagahama Y; Dewar S; Behnke E; Eliashiv D; Stern JM; Kalender G; Fields TA; Wilson C; Staba R; Engel J; Fried I
    J Neurosurg; 2023 Dec; 139(6):1588-1597. PubMed ID: 37243562
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Practice of stereoelectroencephalography (sEEG) in drug-resistant epilepsy: Retrospective series with surgery and thermocoagulation outcomes.
    Méreaux JL; Gilard V; Le Goff F; Chastan N; Magne N; Gerardin E; Maltête D; Lebas A; Derrey S
    Neurochirurgie; 2020 Jun; 66(3):139-143. PubMed ID: 32278000
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Robot-guided pediatric stereoelectroencephalography: single-institution experience.
    Ho AL; Muftuoglu Y; Pendharkar AV; Sussman ES; Porter BE; Halpern CH; Grant GA
    J Neurosurg Pediatr; 2018 Nov; 22(5):1-8. PubMed ID: 30117789
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Invasive EEG-electrodes in presurgical evaluation of epilepsies: Systematic analysis of implantation-, video-EEG-monitoring- and explantation-related complications, and review of literature.
    Willems LM; Reif PS; Spyrantis A; Cattani A; Freiman TM; Seifert V; Wagner M; You SJ; Schubert-Bast S; Bauer S; Klein KM; Rosenow F; Strzelczyk A
    Epilepsy Behav; 2019 Feb; 91():30-37. PubMed ID: 29907526
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Stereoelectroencephalography-guided radiofrequency thermocoagulation in the epileptogenic zone: a retrospective study on 89 cases.
    Cossu M; Fuschillo D; Casaceli G; Pelliccia V; Castana L; Mai R; Francione S; Sartori I; Gozzo F; Nobili L; Tassi L; Cardinale F; Lo Russo G
    J Neurosurg; 2015 Dec; 123(6):1358-67. PubMed ID: 26090841
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Robot-assisted stereoelectroencephalography in children.
    McGovern RA; Knight EP; Gupta A; Moosa ANV; Wyllie E; Bingaman WE; Gonzalez-Martinez J
    J Neurosurg Pediatr; 2018 Dec; 23(3):288-296. PubMed ID: 30544342
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Monopolar stereoelectroencephalography-guided radiofrequency thermocoagulation.
    Minkin KT; Gabrovski KR; Milenova YT; Karazapryanov PA; Sirakov SS; Dimova PS
    J Neurosurg; 2024 Apr; 140(4):1129-1136. PubMed ID: 38564812
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Pediatric stereo-electroencephalography: effects of robot assistance and other variables on seizure outcome and complications.
    Mavridis IN; Lo WB; Wimalachandra WSB; Philip S; Agrawal S; Scott C; Martin-Lamb D; Carr B; Bill P; Lawley A; Seri S; Walsh AR
    J Neurosurg Pediatr; 2021 Jul; 28(4):404-415. PubMed ID: 34298516
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Comparing electrical stimulation functional mapping with subdural electrodes and stereoelectroencephalography.
    Aungaroon G; Vedala K; Byars AW; Ervin B; Rozhkov L; Horn PS; Ihnen SKZ; Holland KD; Tenney JR; Kremer K; Fong SL; Lin N; Liu W; Arthur TM; Fujiwara H; Skoch J; Leach JL; Mangano FT; Greiner HM; Arya R
    Epilepsia; 2023 Jun; 64(6):1527-1540. PubMed ID: 36872854
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 20.