These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

541 related articles for article (PubMed ID: 31431330)

  • 1. Absolute or relative stability in plate fixation for simple humeral shaft fractures.
    van de Wall BJM; Theus C; Link BC; van Veelen N; van de Leeuwen RJH; Ganzert C; Babst R; Beeres FJP
    Injury; 2019 Nov; 50(11):1986-1991. PubMed ID: 31431330
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Absolute or relative stability in minimal invasive plate osteosynthesis of simple distal meta or diaphyseal tibia fractures?
    Wenger R; Oehme F; Winkler J; Perren SM; Babst R; Beeres FJP
    Injury; 2017 Jun; 48(6):1217-1223. PubMed ID: 28302305
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Minimally Invasive Plate Osteosynthesis Using a Screw Compression Method for Treatment of Humeral Shaft Fractures.
    Ko SH; Cha JR; Lee CC; Joo YT; Eom KS
    Clin Orthop Surg; 2017 Dec; 9(4):506-513. PubMed ID: 29201304
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Open reduction and internal fixation of humeral midshaft fractures: anterior versus posterior plate fixation.
    Lotzien S; Hoberg C; Rausch V; Rosteius T; Schildhauer TA; Gessmann J
    BMC Musculoskelet Disord; 2019 Nov; 20(1):527. PubMed ID: 31707990
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Narrow locking compression plate vs long philos plate for minimally invasive plate osteosynthesis of spiral humerus shaft fractures.
    Jeong JJ; Park SE; Lee HH; Ji JH; Park MS; Park YT
    BMC Musculoskelet Disord; 2019 Aug; 20(1):381. PubMed ID: 31421675
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Minimally invasive plate osteosynthesis vs conventional fixation techniques for surgically treated humeral shaft fractures: a meta-analysis.
    Hu X; Xu S; Lu H; Chen B; Zhou X; He X; Dai J; Zhang Z; Gong S
    J Orthop Surg Res; 2016 May; 11(1):59. PubMed ID: 27169580
    [TBL] [Abstract][Full Text] [Related]  

  • 7.  Time until union in absolute vs. relative stability MIPO plating in simple humeral shaft fractures.
    Rellán I; Gallucci GL; Donndorff AG; De Carli P; Zaidenberg EE; Richard MJ; Boretto JG
    Eur J Orthop Surg Traumatol; 2022 Jan; 32(1):191-197. PubMed ID: 33778903
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A prospective randomized study of operative treatment for noncomminuted humeral shaft fractures: conventional open plating versus minimal invasive plate osteosynthesis.
    Kim JW; Oh CW; Byun YS; Kim JJ; Park KC
    J Orthop Trauma; 2015 Apr; 29(4):189-94. PubMed ID: 25210833
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Effectiveness comparison of two minimally invasive plate osteosynthesis techniques for proximal humeral shaft fractures].
    Wang X; Sun K; Tang L; Liang B; Yin D
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2023 Feb; 37(2):147-152. PubMed ID: 36796807
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Plating of humeral shaft fractures: comparison of standard conventional plating versus minimally invasive plating.
    Oh CW; Byun YS; Oh JK; Kim JJ; Jeon IH; Lee JH; Park KH
    Orthop Traumatol Surg Res; 2012 Feb; 98(1):54-60. PubMed ID: 22204793
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparison between antegrade intramedullary nailing (IMN), open reduction plate osteosynthesis (ORPO) and minimally invasive plate osteosynthesis (MIPO) in treatment of humerus diaphyseal fractures.
    Kulkarni VS; Kulkarni MS; Kulkarni GS; Goyal V; Kulkarni MG
    Injury; 2017 Aug; 48 Suppl 2():S8-S13. PubMed ID: 28802426
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [A comparative study on open reduction and plating osteosynthesis and minimal invasive plating osteosynthesis in treating mid-distal humeral shaft fractures].
    An Z; He X; Zeng B
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2009 Jan; 23(1):41-4. PubMed ID: 19192876
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Treatment of humeral shaft fractures: a new minimally-invasive plate osteosynthesis versus open reduction and internal fixation: a case control study.
    Yang J; Liu D; Zhang L; Lu Z; Liu T; Tao C
    BMC Surg; 2021 Sep; 21(1):349. PubMed ID: 34551734
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Dynamic Fixation of Humeral Shaft Fractures Using Active Locking Plates: A Prospective Observational Study.
    Madey SM; Tsai S; Fitzpatrick DC; Earley K; Lutsch M; Bottlang M
    Iowa Orthop J; 2017; 37():1-10. PubMed ID: 28852327
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Minimally invasive plate osteosynthesis (MIPO) of the humeral shaft fracture. Is it possible? A cadaveric study and preliminary report.
    Apivatthakakul T; Arpornchayanon O; Bavornratanavech S
    Injury; 2005 Apr; 36(4):530-8. PubMed ID: 15755436
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Anterior medial minimally invasive plate osteosynthesis for humeral shaft fractures shows superior early shoulder and elbow function compared to locking compression plate: A retrospective study.
    Yang Z; Ouyang B; Yang J; Liu D; Kang X
    Injury; 2024 Aug; 55(8):111692. PubMed ID: 38945080
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Minimally-invasive locking compression plate to treat complex humeral shaft fracture].
    Yang T; Liu S; Liu Y
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2007 Aug; 21(8):817-9. PubMed ID: 17882875
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Outcomes of distal femoral fractures treated with minimally invasive plate osteosynthesis versus open reduction internal fixation with combined locking plate and interfragmentary screws.
    Wang SH; Wu CC; Li WT; Shen HC; Lin LC; Pan RY
    Int J Surg; 2019 May; 65():107-112. PubMed ID: 30951872
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Surgical treatment of humeral diaphyseal fractures].
    Smejkal K; Lochman P; Dědek T; Trlica J
    Acta Chir Orthop Traumatol Cech; 2014; 81(2):129-34. PubMed ID: 25105787
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison between open plating versus minimally invasive plate osteosynthesis for acute displaced clavicular shaft fractures.
    Sohn HS; Kim WJ; Shon MS
    Injury; 2015 Aug; 46(8):1577-84. PubMed ID: 26077663
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 28.