These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

177 related articles for article (PubMed ID: 31432355)

  • 1. Choroidal thickness in keratoconus.
    Bilgin B; Karadag AS
    Int Ophthalmol; 2020 Jan; 40(1):135-140. PubMed ID: 31432355
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparison of Scheimpflug and swept-source anterior segment optical coherence tomography in normal and keratoconus eyes.
    Ghoreishi SM; Mortazavi SAA; Abtahi ZA; Abtahi MA; Sonbolestan SA; Abtahi SH; Mohammadinia M; Isfahani KN
    Int Ophthalmol; 2017 Aug; 37(4):965-971. PubMed ID: 27671494
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Corneal thickness and elevation measurements using swept-source optical coherence tomography and slit scanning topography in normal and keratoconic eyes.
    Jhanji V; Yang B; Yu M; Ye C; Leung CK
    Clin Exp Ophthalmol; 2013 Nov; 41(8):735-45. PubMed ID: 23566209
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of corneal measurements in keratoconus using swept-source optical coherence tomography and combined Placido-Scheimpflug imaging.
    Chan TCY; Biswas S; Yu M; Jhanji V
    Acta Ophthalmol; 2017 Sep; 95(6):e486-e494. PubMed ID: 27805316
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Macular and Peripapillary Choroidal Thickness in Patients With Keratoconus.
    Akkaya S
    Ophthalmic Surg Lasers Imaging Retina; 2018 Sep; 49(9):664-673. PubMed ID: 30222800
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Keratoconus diagnosis with optical coherence tomography pachymetry mapping.
    Li Y; Meisler DM; Tang M; Lu AT; Thakrar V; Reiser BJ; Huang D
    Ophthalmology; 2008 Dec; 115(12):2159-66. PubMed ID: 18977536
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Quantitative Evaluation of the Natural Progression of Keratoconus Using Three-Dimensional Optical Coherence Tomography.
    Fujimoto H; Maeda N; Shintani A; Nakagawa T; Fuchihata M; Higashiura R; Nishida K
    Invest Ophthalmol Vis Sci; 2016 Jul; 57(9):OCT169-75. PubMed ID: 27409469
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Repeatability of anterior segment measurements by optical coherence tomography combined with Placido disk corneal topography in eyes with keratoconus.
    Schiano-Lomoriello D; Bono V; Abicca I; Savini G
    Sci Rep; 2020 Jan; 10(1):1124. PubMed ID: 31980662
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Contribution of Fourier-domain optical coherence tomography to the diagnosis of keratoconus progression.
    Ouanezar S; Sandali O; Atia R; Temstet C; Georgeon C; Laroche L; Borderie V; Bouheraoua N
    J Cataract Refract Surg; 2019 Feb; 45(2):159-166. PubMed ID: 30367937
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Differentiating Keratoconus and Corneal Warpage by Analyzing Focal Change Patterns in Corneal Topography, Pachymetry, and Epithelial Thickness Maps.
    Tang M; Li Y; Chamberlain W; Louie DJ; Schallhorn JM; Huang D
    Invest Ophthalmol Vis Sci; 2016 Jul; 57(9):OCT544-9. PubMed ID: 27482824
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Fourier-domain optical coherence tomography imaging in keratoconus: a corneal structural classification.
    Sandali O; El Sanharawi M; Temstet C; Hamiche T; Galan A; Ghouali W; Goemaere I; Basli E; Borderie V; Laroche L
    Ophthalmology; 2013 Dec; 120(12):2403-2412. PubMed ID: 23932599
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Corneal epithelial thickness mapping using Fourier-domain optical coherence tomography for detection of form fruste keratoconus.
    Temstet C; Sandali O; Bouheraoua N; Hamiche T; Galan A; El Sanharawi M; Basli E; Laroche L; Borderie V
    J Cataract Refract Surg; 2015 Apr; 41(4):812-20. PubMed ID: 25840306
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Distinguishing Highly Asymmetric Keratoconus Eyes Using Combined Scheimpflug and Spectral-Domain OCT Analysis.
    Hwang ES; Perez-Straziota CE; Kim SW; Santhiago MR; Randleman JB
    Ophthalmology; 2018 Dec; 125(12):1862-1871. PubMed ID: 30055838
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Corneal thickness in keratoconus: comparing optical, ultrasound, and optical coherence tomography pachymetry.
    Dutta D; Rao HL; Addepalli UK; Vaddavalli PK
    Ophthalmology; 2013 Mar; 120(3):457-463. PubMed ID: 23177363
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Measuring corneal astigmatism using OCT in keratoconus.
    Llorens-Quintana C; Lee DJ; Pavlatos E; Chamberlain W; Huang D; Li Y
    J Cataract Refract Surg; 2022 Nov; 48(11):1285-1291. PubMed ID: 35616503
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparison of corneal epithelial and stromal thickness distributions between eyes with keratoconus and healthy eyes with corneal astigmatism ≥ 2.0 D.
    Zhou W; Stojanovic A
    PLoS One; 2014; 9(1):e85994. PubMed ID: 24489687
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Influence of the beam profile crosslinking setting on changes in corneal topography and tomography in progressive keratoconus: Preliminary results.
    Herber R; Kunert KS; Veliká V; Spoerl E; Pillunat LE; Raiskup F
    J Cataract Refract Surg; 2018 Jun; 44(6):718-724. PubMed ID: 29778454
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Distinguishing between contact lens warpage and ectasia: Usefulness of optical coherence tomography epithelial thickness mapping.
    Schallhorn JM; Tang M; Li Y; Louie DJ; Chamberlain W; Huang D
    J Cataract Refract Surg; 2017 Jan; 43(1):60-66. PubMed ID: 28317679
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A case of unilateral circumscribed posterior keratoconus evaluated by three different imaging tools: optical coherence tomography, videokeratography, and Scheimpflug corneal tomography.
    Spadea L; Maraone G; Cagini C
    Int Ophthalmol; 2017 Feb; 37(1):279-283. PubMed ID: 27177621
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Prediction of Best-Corrected Visual Acuity With Swept-Source Optical Coherence Tomography Parameters in Keratoconus.
    Esaka Y; Kojima T; Dogru M; Hasegawa A; Tamaoki A; Uno Y; Nishida T; Nakamura T; Hara S; Ichikawa K
    Cornea; 2019 Sep; 38(9):1154-1160. PubMed ID: 31394554
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.