BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

217 related articles for article (PubMed ID: 31435143)

  • 21. Mathematical arterialisation of peripheral venous blood gas for obtainment of arterial blood gas values: a methodological validation study in the clinical setting.
    Lumholdt M; Damgaard KA; Christensen EF; Leutscher PDC
    J Clin Monit Comput; 2019 Aug; 33(4):733-740. PubMed ID: 30196470
    [TBL] [Abstract][Full Text] [Related]  

  • 22. A Retrospective Database Analysis to Investigate if Electrolytes in Venous Blood are Equivalent to the Levels in Arterial Blood.
    Devaki RN; Kasargod P; Urs AR; Chandrika N
    Indian J Crit Care Med; 2024 May; 28(5):442-446. PubMed ID: 38738198
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Prediction of Arterial Blood Gas Factors from Venous Blood Gas Factors in Intensive Care Unit Admitted Patients.
    Bahmani Bohloli H; Nazarian S; Habibi M; Fallahnia M; Zare A; Bahmanimehr A
    Arch Iran Med; 2018 Jun; 21(6):246-250. PubMed ID: 29940743
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Agreement between venous and arterial blood gas analysis of acid-base status in critical care and ward patients: a retrospective cohort study.
    Martin CM; Priestap F
    Can J Anaesth; 2017 Nov; 64(11):1138-1143. PubMed ID: 28836153
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Utility of venous blood gases in severe sepsis and septic shock.
    White HD; Vazquez-Sandoval A; Quiroga PF; Song J; Jones SF; Arroliga AC
    Proc (Bayl Univ Med Cent); 2018 Jul; 31(3):269-275. PubMed ID: 29904286
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Inter-instrumental comparison for the measurement of electrolytes in patients admitted to the intensive care unit.
    Pant V; Tumbapo A; Karki B
    Int J Gen Med; 2017; 10():145-149. PubMed ID: 28553133
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Reliability of Central Venous Blood Gas Values Compared With Arterial Blood Gas Values in Critically Ill Patients.
    Hyun DG; Ji W; Ahn JH; Oh DK; Huh JW; Hong SB; Koh Y; Lim CM
    Respir Care; 2022 Jul; 67(7):863-870. PubMed ID: 35580909
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Correlation and Interchangeability of Venous and Capillary Blood Gases in Non-Critically Ill Neonates.
    Tan RNGB; Pauws SC; van Loon E; Smits VEHJ; Lopriore E; Te Pas AB
    Front Pediatr; 2018; 6():89. PubMed ID: 29755961
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Comparison of the point-of-care blood gas analyzer versus the laboratory auto-analyzer for the measurement of electrolytes.
    Jain A; Subhan I; Joshi M
    Int J Emerg Med; 2009 Feb; 2(2):117-20. PubMed ID: 20157454
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Analysis of bias in measurements of potassium, sodium and hemoglobin by an emergency department-based blood gas analyzer relative to hospital laboratory autoanalyzer results.
    Zhang JB; Lin J; Zhao XD
    PLoS One; 2015; 10(4):e0122383. PubMed ID: 25849375
    [TBL] [Abstract][Full Text] [Related]  

  • 31. The role of venous blood gas in the emergency department: a systematic review and meta-analysis.
    Bloom BM; Grundlingh J; Bestwick JP; Harris T
    Eur J Emerg Med; 2014 Apr; 21(2):81-8. PubMed ID: 23903783
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Correlation of central venous and arterial blood gas measurements in mechanically ventilated trauma patients.
    Malinoski DJ; Todd SR; Slone S; Mullins RJ; Schreiber MA
    Arch Surg; 2005 Nov; 140(11):1122-5. PubMed ID: 16342377
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Comparison of two portable clinical analyzers to one stationary analyzer for the determination of blood gas partial pressures and blood electrolyte concentrations in horses.
    Kirsch K; Detilleux J; Serteyn D; Sandersen C
    PLoS One; 2019; 14(2):e0211104. PubMed ID: 30768603
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Exploring the Feasibility of Calculating Expected pCO2 From Venous Blood Gas Samples Alone in Intensive Care Patients.
    Turhan S; Tutan D; Şahiner Y
    Cureus; 2023 Aug; 15(8):e42944. PubMed ID: 37667706
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Agreement between arterial and central venous values for pH, bicarbonate, base excess, and lactate.
    Middleton P; Kelly AM; Brown J; Robertson M
    Emerg Med J; 2006 Aug; 23(8):622-4. PubMed ID: 16858095
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Utility of venous blood gases for the assessment of traumatic shock: a prospective observational study.
    Coggins AR; Vivekanandamoorthy N; Byth K; Aleemullah T; Selvendran ST; Watkins RJ; Shetty AL; Devjak L; Hsu JM
    Emerg Med J; 2021 Sep; 38(9):711-717. PubMed ID: 33789938
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Correlation of Arterial and Venous pH and Bicarbonate in Patients With Renal Failure.
    Ayaz F; Furrukh M; Arif T; Ur Rahman F; Ambreen S
    Cureus; 2021 Nov; 13(11):e19519. PubMed ID: 34934543
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Can Venous Blood Gas Be Used as an Alternative to Arterial Blood Gas in Intubated Patients at Admission to the Emergency Department? A Retrospective Study.
    Schütz N; Roth D; Schwameis M; Röggla M; Domanovits H
    Open Access Emerg Med; 2019; 11():305-312. PubMed ID: 31920407
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Evaluation of relationship between arterial and venous blood gas values in the patients with tricyclic antidepressant poisoning.
    Eizadi-Mood N; Moein N; Saghaei M
    Clin Toxicol (Phila); 2005; 43(5):357-60. PubMed ID: 16235510
    [TBL] [Abstract][Full Text] [Related]  

  • 40. How reliable are electrolyte and metabolite results measured by a blood gas analyzer in the ED?
    Uysal E; Acar YA; Kutur A; Cevik E; Salman N; Tezel O
    Am J Emerg Med; 2016 Mar; 34(3):419-24. PubMed ID: 26658635
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 11.