These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

150 related articles for article (PubMed ID: 31435762)

  • 1. 2D shear wave elastography: measurement acquisition and reliability criteria in noninvasive assessment of liver fibrosis.
    Chung M; Baird GL; Weiss KE; Beland MD
    Abdom Radiol (NY); 2019 Oct; 44(10):3285-3294. PubMed ID: 31435762
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparison of Two-Dimensional Shear Wave Elastography and Real-Time Tissue Elastography for Assessing Liver Fibrosis in Chronic Hepatitis B.
    Wu T; Wang P; Zhang T; Zheng J; Li S; Zeng J; Kudo M; Zheng R
    Dig Dis; 2016; 34(6):640-649. PubMed ID: 27750231
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Two-dimensional shear wave elastography with propagation-based reliability assessment for grading hepatic fibrosis and portal hypertension.
    Maruyama H; Kobayashi K; Kiyono S; Sekimoto T; Kanda T; Yokosuka O
    J Hepatobiliary Pancreat Sci; 2016 Sep; 23(9):595-602. PubMed ID: 27440720
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of 2D Shear Wave Elastography, Transient Elastography, and MR Elastography for the Diagnosis of Fibrosis in Patients With Nonalcoholic Fatty Liver Disease.
    Furlan A; Tublin ME; Yu L; Chopra KB; Lippello A; Behari J
    AJR Am J Roentgenol; 2020 Jan; 214(1):W20-W26. PubMed ID: 31714842
    [No Abstract]   [Full Text] [Related]  

  • 5. Two-dimensional ultrasound shear wave elastography for identifying and staging liver fibrosis in pediatric patients with known or suspected liver disease: a clinical effectiveness study.
    Alhashmi GH; Gupta A; Trout AT; Dillman JR
    Pediatr Radiol; 2020 Aug; 50(9):1255-1262. PubMed ID: 32588095
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Assessment of Fibrosis in Liver Transplant Recipients: Diagnostic Performance of Shear Wave Elastography (SWE) and Correlation of SWE Findings With Biopsy Results.
    Deurdulian C; Grant EG; Tchelepi H; Latterman PT; Paluch JT; Chopra S; Kazmierski B; Kahn JA; Malhi H; Cen SY
    AJR Am J Roentgenol; 2019 Dec; 213(6):W264-W271. PubMed ID: 31573849
    [No Abstract]   [Full Text] [Related]  

  • 7. Two-Dimensional-Shear Wave Elastography with a Propagation Map: Prospective Evaluation of Liver Fibrosis Using Histopathology as the Reference Standard.
    Lee DH; Lee ES; Lee JY; Bae JS; Kim H; Lee KB; Yu SJ; Cho EJ; Lee JH; Cho YY; Han JK; Choi BI
    Korean J Radiol; 2020 Dec; 21(12):1317-1325. PubMed ID: 32729274
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Which are the cut-off values of 2D-Shear Wave Elastography (2D-SWE) liver stiffness measurements predicting different stages of liver fibrosis, considering Transient Elastography (TE) as the reference method?
    Sporea I; Bota S; Gradinaru-Taşcău O; Sirli R; Popescu A; Jurchiş A
    Eur J Radiol; 2014 Mar; 83(3):e118-22. PubMed ID: 24380640
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Assessing Hepatic Fibrosis Using 2-D Shear Wave Elastography in Patients with Liver Tumors: A Prospective Single-Center Study.
    Huang Z; Zheng W; Zhang YJ; Xu L; Chen JB; Chen JC; Chen MS; Zhou Z
    Ultrasound Med Biol; 2017 Nov; 43(11):2522-2529. PubMed ID: 28807448
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Two-dimensional shear wave elastography for assessing liver fibrosis in patients with chronic liver disease: a prospective cohort study.
    Yoo HW; Kim SG; Jang JY; Yoo JJ; Jeong SW; Kim YS; Kim BS
    Korean J Intern Med; 2022 Mar; 37(2):285-293. PubMed ID: 34865414
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Acoustic radiation force impulse elastography as compared to transient elastography and liver biopsy in patients with chronic hepatopathies.
    Sporea I; Sirli RL; Deleanu A; Popescu A; Focsa M; Danila M; Tudora A
    Ultraschall Med; 2011 Jan; 32 Suppl 1():S46-52. PubMed ID: 20603783
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Shear wave elastography correlates with liver fibrosis scores in pediatric patients with liver disease.
    Farmakis SG; Buchanan PM; Guzman MA; Hardy AK; Jain AK; Teckman JH
    Pediatr Radiol; 2019 Dec; 49(13):1742-1753. PubMed ID: 31418057
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Liver Stiffness Measurements by 2D Shear-Wave Elastography: Effect of Steatosis on Fibrosis Evaluation.
    Kumada T; Toyoda H; Yasuda S; Ogawa S; Gotoh T; Ito T; Tada T; Tanaka J
    AJR Am J Roentgenol; 2022 Oct; 219(4):604-612. PubMed ID: 35506556
    [No Abstract]   [Full Text] [Related]  

  • 14. The Performance of a 2-Dimensional Shear-Wave Elastography Technique for Predicting Different Stages of Liver Fibrosis Using Transient Elastography as the Control Method.
    Bende F; Sporea I; Şirli R; Nistorescu S; Fofiu R; Bâldea V; Popescu A
    Ultrasound Q; 2020 Nov; 37(2):97-104. PubMed ID: 33136935
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Utility of shear-wave elastography to differentiate low from advanced degrees of liver fibrosis in patients with hepatitis C virus infection of native and transplant livers.
    Rattansingh A; Amooshahi H; Menezes RJ; Wong F; Fischer S; Kirsch R; Atri M
    J Clin Ultrasound; 2018 Jun; 46(5):311-318. PubMed ID: 29508406
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Variability of Liver Shear Wave Measurements Using a New Ultrasound Elastographic Technique.
    Nadebaum DP; Nicoll AJ; Sood S; Gorelik A; Gibson RN
    J Ultrasound Med; 2018 Mar; 37(3):647-656. PubMed ID: 28960385
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Assessment of liver fibrosis in chronic hepatitis: comparison of shear wave elastography and transient elastography.
    Paul SB; Das P; Mahanta M; Sreenivas V; Kedia S; Kalra N; Kaur H; Vijayvargiya M; Ghosh S; Gamanagatti SR; Shalimar ; Gupta SD; Acharya SK
    Abdom Radiol (NY); 2017 Dec; 42(12):2864-2873. PubMed ID: 28643136
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Coefficient of Variance as Quality Criterion for Evaluation of Advanced Hepatic Fibrosis Using 2D Shear-Wave Elastography.
    Lim S; Kim SH; Kim Y; Cho YS; Kim TY; Jeong WK; Sohn JH
    J Ultrasound Med; 2018 Feb; 37(2):355-362. PubMed ID: 28804946
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Two-Dimensional Shear Wave Elastography Predicts Liver Fibrosis in Jaundiced Infants with Suspected Biliary Atresia: A Prospective Study.
    Chen H; Zhou L; Liao B; Cao Q; Jiang H; Zhou W; Wang G; Xie X
    Korean J Radiol; 2021 Jun; 22(6):959-969. PubMed ID: 33569934
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Reliability Criteria of Two-Dimensional Shear Wave Elastography: Analysis of 4277 Measurements in 788 Patients.
    Paisant A; Lemoine S; Cassinotto C; de Lédinghen V; Ronot M; Irlès-Depé M; Vilgrain V; Le Bail B; Paradis V; Canivet CM; Michalak S; Rousselet MC; Rautou PE; Lebigot J; Hunault G; Crouan A; Aubé C; Boursier J
    Clin Gastroenterol Hepatol; 2022 Feb; 20(2):400-408.e10. PubMed ID: 33340779
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.