These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

178 related articles for article (PubMed ID: 31436344)

  • 1. In Vitro Evidence for Cell-Accelerated Corrosion Within Modular Junctions of Total Hip Replacements.
    Bijukumar DR; Salunkhe S; Morris D; Segu A; Hall DJ; Pourzal R; Mathew MT
    J Orthop Res; 2020 Feb; 38(2):393-404. PubMed ID: 31436344
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Wear particles induce a new macrophage phenotype with the potential to accelerate material corrosion within total hip replacement interfaces.
    Bijukumar DR; Salunkhe S; Zheng G; Barba M; Hall DJ; Pourzal R; Mathew MT
    Acta Biomater; 2020 Jan; 101():586-597. PubMed ID: 31678260
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Alloy Microstructure Dictates Corrosion Modes in THA Modular Junctions.
    Pourzal R; Hall DJ; Ehrich J; McCarthy SM; Mathew MT; Jacobs JJ; Urban RM
    Clin Orthop Relat Res; 2017 Dec; 475(12):3026-3043. PubMed ID: 28884275
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Effect of impact assembly on the interface deformation and fretting corrosion of modular hip tapers: An in vitro study.
    Panagiotidou A; Cobb T; Meswania J; Skinner J; Hart A; Haddad F; Blunn G
    J Orthop Res; 2018 Jan; 36(1):405-416. PubMed ID: 28485507
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Mechanical, chemical and biological damage modes within head-neck tapers of CoCrMo and Ti6Al4V contemporary hip replacements.
    Hall DJ; Pourzal R; Lundberg HJ; Mathew MT; Jacobs JJ; Urban RM
    J Biomed Mater Res B Appl Biomater; 2018 Jul; 106(5):1672-1685. PubMed ID: 28842959
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Investigation of cell-accelerated corrosion (CAC) on the CoCrMo alloy with segregation banding: Hip implant applications.
    Kanniyappan H; Cheng KY; Badhe RV; Neto M; Bijukumar D; Barba M; Pourzal R; Mathew M
    J Mech Behav Biomed Mater; 2024 Apr; 152():106449. PubMed ID: 38387118
    [TBL] [Abstract][Full Text] [Related]  

  • 7. In vitro fretting crevice corrosion damage of CoCrMo alloys in phosphate buffered saline: Debris generation, chemistry and distribution.
    Zhu D; Liu Y; Gilbert JL
    Acta Biomater; 2020 Sep; 114():449-459. PubMed ID: 32771589
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The role of Vitamin E in hip implant-related corrosion and toxicity: Initial outcome.
    Manjunath V; Badhe RV; McCoy M; Rynne J; Bhatti A; Segu A; Oral E; Jacobs JJ; Chastain P; Bijukumar D; Mathew MT
    J Mech Behav Biomed Mater; 2021 Nov; 123():104769. PubMed ID: 34412025
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Failure mechanisms in CoCrMo modular femoral stems for revision total hip arthroplasty.
    Wang Q; Parry M; Masri BA; Duncan C; Wang R
    J Biomed Mater Res B Appl Biomater; 2017 Aug; 105(6):1525-1535. PubMed ID: 27122233
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Release of metal ions from nano CoCrMo wear debris generated from tribo-corrosion processes in artificial hip implants.
    Wang Y; Yan Y; Su Y; Qiao L
    J Mech Behav Biomed Mater; 2017 Apr; 68():124-133. PubMed ID: 28161662
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Fretting-corrosion behavior in hip implant modular junctions: The influence of friction energy and pH variation.
    Royhman D; Patel M; Runa MJ; Wimmer MA; Jacobs JJ; Hallab NJ; Mathew MT
    J Mech Behav Biomed Mater; 2016 Sep; 62():570-587. PubMed ID: 27310572
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Nontribological corrosion modes dominate wrought CoCrMo acetabular taper corrosion: A retrieval study.
    Shenoy AA; Kurtz SM; Gilbert JL
    J Biomed Mater Res B Appl Biomater; 2021 Dec; 109(12):2000-2013. PubMed ID: 33945667
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A comparative study on the physicochemical characteristics of nanoparticles released in vivo from CoCrMo tapers and cement-stem interfaces of total hip replacements.
    Crainic AM; Callisti M; van Veelen A; Michalik A; Milton JA; Palmer MR; Cook RB
    J Biomed Mater Res B Appl Biomater; 2020 Nov; 108(8):3311-3322. PubMed ID: 32596955
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Hip implant modular junction: The role of CoCrMo alloy microstructure on fretting-corrosion.
    Manthe J; Cheng KY; Bijukumar D; Barba M; Pourzal R; Neto M; Mathew MT
    J Mech Behav Biomed Mater; 2022 Oct; 134():105402. PubMed ID: 36041275
    [TBL] [Abstract][Full Text] [Related]  

  • 15. In vitro simulation of fretting-corrosion in hip implant modular junctions: The influence of pH.
    Royhman D; Patel M; Jacobs JJ; Wimmer MA; Hallab NJ; Mathew MT
    Med Eng Phys; 2018 Feb; 52():1-9. PubMed ID: 29290499
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The role of fretting-frequency on the damage modes of THR modular junction: In-vitro study.
    Radzik B; Bijukumar D; Cheng KY; Badhe RV; Barba M; Mathew MT
    Mater Sci Eng C Mater Biol Appl; 2021 Jul; 126():112128. PubMed ID: 34082945
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Enhanced wear and corrosion in modular tapers in total hip replacement is associated with the contact area and surface topography.
    Panagiotidou A; Meswania J; Hua J; Muirhead-Allwood S; Hart A; Blunn G
    J Orthop Res; 2013 Dec; 31(12):2032-9. PubMed ID: 23966288
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The effect of simulated inflammatory conditions and Fenton chemistry on the electrochemistry of CoCrMo alloy.
    Liu Y; Gilbert JL
    J Biomed Mater Res B Appl Biomater; 2018 Jan; 106(1):209-220. PubMed ID: 28117942
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Sensing Localized Surface Corrosion Damage of CoCrMo Alloys and Modular Tapers of Total Hip Retrievals Using Nearfield Electrochemical Impedance Spectroscopy.
    Wiegand MJ; Shenoy AA; Littlejohn SE; Gilbert JL
    ACS Biomater Sci Eng; 2020 Mar; 6(3):1344-1354. PubMed ID: 33455367
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Breakage of metal hip arthroplasty components: Retrieval and structural analysis.
    Łapaj Ł; Woźniak W; Wiśniewski T; Rozwalka J; Paczesny Ł; Zabrzyński J; Janusz P; Kruczyński J
    Biomed Mater Eng; 2019; 30(3):297-308. PubMed ID: 31006657
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.