These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
495 related articles for article (PubMed ID: 31436825)
1. Do patients with the centrifugal flow HeartMate 3 or HeartWare left ventricular assist device have better outcomes compared to those with axial flow HeartMate II? Florisson DS; Conte SM; De Bono JA; Newcomb AE Interact Cardiovasc Thorac Surg; 2019 Dec; 29(6):844-851. PubMed ID: 31436825 [TBL] [Abstract][Full Text] [Related]
2. Comprehensive Analysis of Stroke in the Long-Term Cohort of the MOMENTUM 3 Study. Colombo PC; Mehra MR; Goldstein DJ; Estep JD; Salerno C; Jorde UP; Cowger JA; Cleveland JC; Uriel N; Sayer G; Skipper ER; Downey FX; Ono M; Hooker R; Anyanwu AC; Givertz MM; Mahr C; Topuria I; Somo SI; Crandall DL; Horstmanshof DA Circulation; 2019 Jan; 139(2):155-168. PubMed ID: 30586698 [TBL] [Abstract][Full Text] [Related]
3. Identifying patients at risk: multi-centre comparison of HeartMate 3 and HeartWare left ventricular assist devices. Numan L; Zimpfer D; Zadok OIB; Aarts E; Morshuis M; Guenther SPW; Riebandt J; Wiedemann D; Ramjankhan FZ; Oppelaar AM; Ben-Gal T; Ben-Avraham B; Asselbergs FW; Schramm R; Van Laake LW ESC Heart Fail; 2023 Jun; 10(3):1656-1665. PubMed ID: 36798028 [TBL] [Abstract][Full Text] [Related]
4. Clinical differences between continuous flow ventricular assist devices: a comparison between HeartMate II and HeartWare HVAD. Lalonde SD; Alba AC; Rigobon A; Ross HJ; Delgado DH; Billia F; McDonald M; Cusimano RJ; Yau TM; Rao V J Card Surg; 2013 Sep; 28(5):604-10. PubMed ID: 23844652 [TBL] [Abstract][Full Text] [Related]
5. Adverse events in contemporary continuous-flow left ventricular assist devices: A multi-institutional comparison shows significant differences. Stulak JM; Davis ME; Haglund N; Dunlay S; Cowger J; Shah P; Pagani FD; Aaronson KD; Maltais S J Thorac Cardiovasc Surg; 2016 Jan; 151(1):177-89. PubMed ID: 26545967 [TBL] [Abstract][Full Text] [Related]
6. Cerebrovascular Events in Patients With Centrifugal-Flow Left Ventricular Assist Devices: Propensity Score-Matched Analysis From the Intermacs Registry. Cho SM; Mehaffey JH; Meyers SL; Cantor RS; Starling RC; Kirklin JK; Jacobs JP; Kern J; Uchino K; Yarboro LT Circulation; 2021 Sep; 144(10):763-772. PubMed ID: 34491776 [TBL] [Abstract][Full Text] [Related]
7. Cerebrovascular Events in Patients With Centrifugal-Flow Left Ventricular Assist Devices: Propensity Score-Matched Analysis From the Intermacs Registry. Cho SM; Mehaffey JH; Meyers SL; Cantor RS; Starling RC; Kirklin JK; Jacobs JP; Kern J; Uchino K; Yarboro LT Circulation; 2021 Sep; 144(10):763-772. PubMed ID: 34315231 [TBL] [Abstract][Full Text] [Related]
8. Propensity score-based analysis of long-term outcome of patients on HeartWare and HeartMate 3 left ventricular assist device support. Numan L; Ramjankhan FZ; Oberski DL; Oerlemans MIFJ; Aarts E; Gianoli M; Van Der Heijden JJ; De Jonge N; Van Der Kaaij NP; Meuwese CL; Mokhles MM; Oppelaar AM; De Waal EEC; Asselbergs FW; Van Laake LW ESC Heart Fail; 2021 Apr; 8(2):1596-1603. PubMed ID: 33635573 [TBL] [Abstract][Full Text] [Related]
9. Association of Clinical Outcomes With Left Ventricular Assist Device Use by Bridge to Transplant or Destination Therapy Intent: The Multicenter Study of MagLev Technology in Patients Undergoing Mechanical Circulatory Support Therapy With HeartMate 3 (MOMENTUM 3) Randomized Clinical Trial. Goldstein DJ; Naka Y; Horstmanshof D; Ravichandran AK; Schroder J; Ransom J; Itoh A; Uriel N; Cleveland JC; Raval NY; Cogswell R; Suarez EE; Lowes BD; Kim G; Bonde P; Sheikh FH; Sood P; Farrar DJ; Mehra MR JAMA Cardiol; 2020 Apr; 5(4):411-419. PubMed ID: 31939996 [TBL] [Abstract][Full Text] [Related]
10. Effects of a fully magnetically levitated centrifugal-flow or axial-flow left ventricular assist device on von Willebrand factor: A prospective multicenter clinical trial. Bansal A; Uriel N; Colombo PC; Narisetty K; Long JW; Bhimaraj A; Cleveland JC; Goldstein DJ; Stulak JM; Najjar SS; Lanfear DE; Adler ED; Dembitsky WP; Somo SI; Crandall DL; Chen D; Connors JM; Mehra MR J Heart Lung Transplant; 2019 Aug; 38(8):806-816. PubMed ID: 31147187 [TBL] [Abstract][Full Text] [Related]
11. Stroke and Intracranial Hemorrhage in HeartMate II and HeartWare Left Ventricular Assist Devices: A Systematic Review. Cho SM; Moazami N; Frontera JA Neurocrit Care; 2017 Aug; 27(1):17-25. PubMed ID: 28324260 [TBL] [Abstract][Full Text] [Related]
12. Healthcare Resource Use and Cost Implications in the MOMENTUM 3 Long-Term Outcome Study. Mehra MR; Salerno C; Cleveland JC; Pinney S; Yuzefpolskaya M; Milano CA; Itoh A; Goldstein DJ; Uriel N; Gulati S; Pagani FD; John R; Adamson R; Bogaev R; Thohan V; Chuang J; Sood P; Goates S; Silvestry SC Circulation; 2018 Oct; 138(18):1923-1934. PubMed ID: 29807933 [TBL] [Abstract][Full Text] [Related]
13. Hemocompatibility-Related Outcomes in the MOMENTUM 3 Trial at 6 Months: A Randomized Controlled Study of a Fully Magnetically Levitated Pump in Advanced Heart Failure. Uriel N; Colombo PC; Cleveland JC; Long JW; Salerno C; Goldstein DJ; Patel CB; Ewald GA; Tatooles AJ; Silvestry SC; John R; Caldeira C; Jeevanandam V; Boyle AJ; Sundareswaran KS; Sood P; Mehra MR Circulation; 2017 May; 135(21):2003-2012. PubMed ID: 28385948 [TBL] [Abstract][Full Text] [Related]
14. Retrospective 1-year outcome follow-up in 200 patients supported with HeartMate 3 and HeartWare left ventricular assist devices in a single centre. Mueller M; Hoermandinger C; Richter G; Mulzer J; Tsyganenko D; Krabatsch T; Starck C; Stein J; Schoenrath F; Falk V; Potapov E Eur J Cardiothorac Surg; 2020 Jun; 57(6):1160-1165. PubMed ID: 32298426 [TBL] [Abstract][Full Text] [Related]
15. Characteristics of strokes associated with centrifugal flow left ventricular assist devices. Inamullah O; Chiang YP; Bishawi M; Weiss M; Lutz MW; Blue LJ; Feng W; Milano CA; Luedke M; Husseini NE Sci Rep; 2021 Jan; 11(1):1645. PubMed ID: 33462301 [TBL] [Abstract][Full Text] [Related]
16. Early Outcomes After Heart Transplantation in Recipients Bridged With a HeartMate 3 Device. Suarez-Pierre A; Lui C; Zhou X; Crawford TC; Fraser CD; Giuliano K; Hsu S; Higgins RS; Zehr KJ; Whitman GJ; Choi CW; Kilic A Ann Thorac Surg; 2019 Aug; 108(2):467-473. PubMed ID: 30880137 [TBL] [Abstract][Full Text] [Related]
17. Left Ventricular Assist Device Flow Pattern Analysis Using a Novel Model Incorporating Left Ventricular Pulsatility. Grinstein J; Torii R; Bourantas CV; Garcia-Garcia HM ASAIO J; 2021 Jul; 67(7):724-732. PubMed ID: 33528162 [TBL] [Abstract][Full Text] [Related]