These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

188 related articles for article (PubMed ID: 31443403)

  • 1. How to Choose the Superconducting Material Law for the Modelling of 2G-HTS Coils.
    Robert BC; Fareed MU; Ruiz HS
    Materials (Basel); 2019 Aug; 12(17):. PubMed ID: 31443403
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Essential Material Knowledge and Recent Model Developments for REBCO-Coated Conductors in Electric Power Systems.
    Trillaud F; Dos Santos G; Gonçalves Sotelo G
    Materials (Basel); 2021 Apr; 14(8):. PubMed ID: 33920245
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Gradient coil design using Bi-2223 high temperature superconducting tape for magnetic resonance imaging.
    Yuan J; Shen GX
    Med Eng Phys; 2007 May; 29(4):442-8. PubMed ID: 16875861
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Imaging of Strong Nanoscale Vortex Pinning in GdBaCuO High-Temperature Superconducting Tapes.
    Collomb D; Zhang M; Yuan W; Bending SJ
    Nanomaterials (Basel); 2021 Apr; 11(5):. PubMed ID: 33922201
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Investigation of Bi-2223 high temperature superconducting tape as the material for gradient coil in MRI.
    Yuan J; Rohan ML; Shen GX
    J Magn Reson; 2006 Oct; 182(2):298-307. PubMed ID: 16884938
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Designs and Tests of Shaking Coils to Reduce Screening Currents Induced in HTS Insert Coils for NMR Magnet.
    Kajikawa K; Gettliffe GV; Chu Y; Miyagi D; Lécrevisse TP; Hahn S; Bascuñán J; Iwasa Y
    IEEE Trans Appl Supercond; 2015 Jun; 25(3):. PubMed ID: 32952375
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Method for nonlinear characterization of radio frequency coils made of high temperature superconducting material in view of magnetic resonance imaging applications.
    Girard O; Ginefri JC; Poirier-Quinot M; Darrasse L
    Rev Sci Instrum; 2007 Dec; 78(12):124703. PubMed ID: 18163742
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Critical Current Simulation and Measurement of Second Generation, High-Temperature Superconducting Coil under External Magnetic Field.
    Yu D; Liu H; Zhang X; Gong T
    Materials (Basel); 2018 Feb; 11(3):. PubMed ID: 29495386
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Study on Quenching Characteristics and Resistance Equivalent Estimation Method of Second-Generation High Temperature Superconducting Tape under Different Overcurrent.
    Liang S; Ren L; Ma T; Xu Y; Tang Y; Tan X; Li Z; Chen G; Yan S; Cao Z; Shi J; Xiao L; Song M
    Materials (Basel); 2019 Jul; 12(15):. PubMed ID: 31349713
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Experimental Analysis of Critical Current and Alternating Current Losses of High-Temperature Superconductor Tape with Resin and Gallium-Indium-Tin.
    Yu D; Sun Y; Zhang H; Meng Y; Liu H
    Materials (Basel); 2018 Apr; 11(4):. PubMed ID: 29642490
    [TBL] [Abstract][Full Text] [Related]  

  • 11. High-temperature superconducting radiofrequency probe for magnetic resonance imaging applications operated below ambient pressure in a simple liquid-nitrogen cryostat.
    Lambert S; Ginefri JC; Poirier-Quinot M; Darrasse L
    Rev Sci Instrum; 2013 May; 84(5):054701. PubMed ID: 23742569
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Numerical Modelling of the Dynamic Voltage in HTS Materials under the Action of DC Transport Currents and Different Oscillating Magnetic Fields.
    Shen B; Chen X; Fu L; Hao L; Coombs T
    Materials (Basel); 2022 Jan; 15(3):. PubMed ID: 35160742
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Implementation of High-Temperature Superconducting tapes RF coils for 3T MRI system.
    Lin IT; Hsieh CW; Kuo LW; Yang HC; Yao C; Chang WH; Chen JH
    Conf Proc IEEE Eng Med Biol Soc; 2005; 2005():7413-6. PubMed ID: 17281994
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Measurement of AC loss down to 25 K in a REBCO racetrack coil for electrical aircraft motor.
    Kováč J; Kopera Ľ; Pardo E; Melišek T; Ries R; Berberich E; Wolfstädler S; Reis T
    Sci Rep; 2022 Sep; 12(1):16454. PubMed ID: 36180502
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Nature of the low magnetization decay on stacks of second generation superconducting tapes under crossed and rotating magnetic field experiments.
    Baghdadi M; Ruiz HS; Coombs TA
    Sci Rep; 2018 Jan; 8(1):1342. PubMed ID: 29358743
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Superconducting-magnetic heterostructures: a method of decreasing AC losses and improving critical current density in multifilamentary conductors.
    Glowacki BA; Majoros M
    J Phys Condens Matter; 2009 Jun; 21(25):254206. PubMed ID: 21828430
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Design and testing of a system for measuring high-frequency AC losses in superconducting wires and coils carrying DC and AC currents.
    Nikulshin Y; Ginodman V; Friedman A; Yeshurun Y; Wolfus S
    Rev Sci Instrum; 2019 Jun; 90(6):065111. PubMed ID: 31255017
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Modeling cross-field demagnetization of superconducting stacks and bulks for up to 100 tapes and 2 million cycles.
    Dadhich A; Pardo E
    Sci Rep; 2020 Nov; 10(1):19265. PubMed ID: 33159101
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Tape-to-Tape Joint Resistances of a Magnet Assembled From (RE)BCO Double-Pancake Coils.
    Lécrevisse T; Bascuñán J; Hahn S; Kim Y; Song J; Iwasa Y
    IEEE Trans Appl Supercond; 2015 Jun; 25(3):. PubMed ID: 32863689
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Investigation on quench initiation and propagation characteristics of GdBCO coil co-wound with a stainless steel tape as turn-to-turn metallic insulation.
    Kim YG; Song JB; Choi YH; Yang DG; Kim SG; Lee HG
    Rev Sci Instrum; 2016 Nov; 87(11):114701. PubMed ID: 27910603
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.