These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
165 related articles for article (PubMed ID: 31444131)
1. Experimental validation of a new COMS-like 24 mm eye plaque for the treatment of large ocular melanoma tumors. McCauley Cutsinger S; Forsman R; Corner S; Deufel CL Brachytherapy; 2019; 18(6):890-897. PubMed ID: 31444131 [TBL] [Abstract][Full Text] [Related]
2. Monte Carlo dosimetry for 125I and 103Pd eye plaque brachytherapy with various seed models. Thomson RM; Rogers DW Med Phys; 2010 Jan; 37(1):368-76. PubMed ID: 20175499 [TBL] [Abstract][Full Text] [Related]
3. Evaluation of material heterogeneity dosimetric effects using radiochromic film for COMS eye plaques loaded with (125)I seeds (model I25.S16). Acar H; Chiu-Tsao ST; Ozbay I; Kemikler G; Tuncer S Med Phys; 2013 Jan; 40(1):011708. PubMed ID: 23298078 [TBL] [Abstract][Full Text] [Related]
4. Monte Carlo dosimetry for 125I and 103Pd eye plaque brachytherapy. Thomson RM; Taylor RE; Rogers DW Med Phys; 2008 Dec; 35(12):5530-43. PubMed ID: 19175111 [TBL] [Abstract][Full Text] [Related]
5. Comparison of 16 mm OSU-Nag and COMS eye plaques. Zhang H; Davidorf F; Qi Y J Appl Clin Med Phys; 2012 May; 13(3):3632. PubMed ID: 22584165 [TBL] [Abstract][Full Text] [Related]
6. Design and dosimetric considerations of a modified COMS plaque: the reusable "seed-guide" insert. Astrahan MA; Szechter A; Finger PT Med Phys; 2005 Aug; 32(8):2706-16. PubMed ID: 16193802 [TBL] [Abstract][Full Text] [Related]
7. Dosimetry of (125)I and (103)Pd COMS eye plaques for intraocular tumors: report of Task Group 129 by the AAPM and ABS. Chiu-Tsao ST; Astrahan MA; Finger PT; Followill DS; Meigooni AS; Melhus CS; Mourtada F; Napolitano ME; Nath R; Rivard MJ; Rogers DW; Thomson RM Med Phys; 2012 Oct; 39(10):6161-84. PubMed ID: 23039655 [TBL] [Abstract][Full Text] [Related]
8. How to design, fabricate, and validate a customized COMS-style eye plaque: Illustrated with a narrow-slotted plaque example. Deufel CL; Dalvin LA; Qian J; Vaishnav B; Cutsinger JM; Wittich MN; Petersen IA Brachytherapy; 2021; 20(6):1235-1244. PubMed ID: 34217602 [TBL] [Abstract][Full Text] [Related]
9. Heterogeneous dose calculations for Collaborative Ocular Melanoma Study eye plaques using actual seed configurations and Task Group Report 43 formalism. Deufel CL; Furutani KM Brachytherapy; 2015; 14(2):209-30. PubMed ID: 25533415 [TBL] [Abstract][Full Text] [Related]
10. Dosimetric comparison of circular Eye Physics and Collaborative Ocular Melanoma Study plaques to treat uveal melanoma. Dean MK; Studenski MT; Paez-Escamilla MA; Walter SD; Kwon D; Markoe AM; Harbour JW; Samuels SE Brachytherapy; 2019; 18(3):404-410. PubMed ID: 30797699 [TBL] [Abstract][Full Text] [Related]
11. Delivered dose uncertainty analysis at the tumor apex for ocular brachytherapy. Morrison H; Menon G; Larocque MP; Jans HS; Weis E; Sloboda RS Med Phys; 2016 Aug; 43(8):4891. PubMed ID: 27487906 [TBL] [Abstract][Full Text] [Related]
12. Investigating the dosimetric impact of seed location uncertainties in Collaborative Ocular Melanoma Study-based eye plaques. Johnson JE; Deufel CL; Furutani KM Brachytherapy; 2016; 15(5):661-8. PubMed ID: 27475484 [TBL] [Abstract][Full Text] [Related]
13. A comprehensive dosimetric comparison between (131)Cs and (125)I brachytherapy sources for COMS eye plaque implant. Zhang H; Martin D; Chiu-Tsao ST; Meigooni A; Thomadsen BR Brachytherapy; 2010; 9(4):362-72. PubMed ID: 20116342 [TBL] [Abstract][Full Text] [Related]
14. Seed coordinates of a new COMS-like 24 mm plaque verified using the FARO Edge. McCauley Cutsinger SE; Furutani KM; Forsman RM; Corner SM J Appl Clin Med Phys; 2015 Nov; 16(6):293-301. PubMed ID: 26699584 [TBL] [Abstract][Full Text] [Related]
15. A practical approach to estimating optic disc dose and macula dose without treatment planning in ocular brachytherapy using Lee YC; Lin SC; Kim Y Radiat Oncol; 2018 Nov; 13(1):221. PubMed ID: 30424782 [TBL] [Abstract][Full Text] [Related]
16. Dosimetric verification of a dedicated 3D treatment planning system for episcleral plaque therapy. Knutsen S; Hafslund R; Monge OR; Valen H; Muren LP; Rekstad BL; Krohn J; Dahl O Int J Radiat Oncol Biol Phys; 2001 Nov; 51(4):1159-66. PubMed ID: 11704341 [TBL] [Abstract][Full Text] [Related]
17. Quantifying the dosimetric influences of radiation coverage and brachytherapy implant placement uncertainty on eye plaque size selection. Gagne NL; Rivard MJ Brachytherapy; 2013; 12(5):508-20. PubMed ID: 23466357 [TBL] [Abstract][Full Text] [Related]
18. Monte Carlo dosimetry of the eye plaque design used at the St. Erik Eye Hospital for (125)I brachytherapy. Karlsson M; Nilsson J; Lundell M; Carlsson Tedgren A Brachytherapy; 2014; 13(6):651-6. PubMed ID: 24950821 [TBL] [Abstract][Full Text] [Related]
19. Comparison of dose calculation methods for brachytherapy of intraocular tumors. Rivard MJ; Chiu-Tsao ST; Finger PT; Meigooni AS; Melhus CS; Mourtada F; Napolitano ME; Rogers DW; Thomson RM; Nath R Med Phys; 2011 Jan; 38(1):306-16. PubMed ID: 21361199 [TBL] [Abstract][Full Text] [Related]
20. Monte Carlo simulation of COMS ophthalmic applicators loaded with Bebig I25.S16 seeds and comparison with planning system predictions. Miras H; Terrón JA; Lallena AM Phys Med; 2013 Nov; 29(6):670-6. PubMed ID: 22858007 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]