These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
331 related articles for article (PubMed ID: 31450539)
21. Mitigation of motion-induced artifacts in cone beam computed tomography using deep convolutional neural networks. Amirian M; Montoya-Zegarra JA; Herzig I; Eggenberger Hotz P; Lichtensteiger L; Morf M; Züst A; Paysan P; Peterlik I; Scheib S; Füchslin RM; Stadelmann T; Schilling FP Med Phys; 2023 Oct; 50(10):6228-6242. PubMed ID: 36995003 [TBL] [Abstract][Full Text] [Related]
22. Physical evaluation of the weighted Feldkamp algorithms applied to the 256-detector row CT scanner for volumetric cine imaging. Mori S; Endo M; Kondo C; Tanada S Acad Radiol; 2006 Jun; 13(6):701-12. PubMed ID: 16679272 [TBL] [Abstract][Full Text] [Related]
23. Faster and lower dose imaging: evaluating adaptive, constant gantry velocity and angular separation in fast low-dose 4D cone beam CT imaging. Lau BKF; Dillon O; Vinod SK; O'Brien RT; Reynolds T Med Phys; 2024 Feb; 51(2):1364-1382. PubMed ID: 37427751 [TBL] [Abstract][Full Text] [Related]
24. Temporal resolution and the evaluation of candidate algorithms for four-dimensional CT. Taguchi K Med Phys; 2003 Apr; 30(4):640-50. PubMed ID: 12722816 [TBL] [Abstract][Full Text] [Related]
25. A high-resolution cone beam computed tomography (HRCBCT) reconstruction framework for CBCT-guided online adaptive therapy. Park JC; Song B; Liang X; Lu B; Tan J; Parisi A; Denbeigh J; Yaddanpudi S; Choi B; Kim JS; Furutani KM; Beltran CJ Med Phys; 2023 Oct; 50(10):6490-6501. PubMed ID: 37690458 [TBL] [Abstract][Full Text] [Related]
26. Potential of iterative reconstruction for maxillofacial cone beam CT imaging: technical note. Matenine D; Kachelriess M; Després P; de Guise JA; Schmittbuhl M Neuroradiology; 2020 Nov; 62(11):1511-1514. PubMed ID: 32556404 [TBL] [Abstract][Full Text] [Related]
27. Metal artifact reduction using iterative CBCT reconstruction algorithm for head and neck radiation therapy: A phantom and clinical study. Washio H; Ohira S; Funama Y; Morimoto M; Wada K; Yagi M; Shimamoto H; Koike Y; Ueda Y; Karino T; Inui S; Nitta Y; Miyazaki M; Teshima T Eur J Radiol; 2020 Nov; 132():109293. PubMed ID: 32987251 [TBL] [Abstract][Full Text] [Related]
28. Low-dose preview for patient-specific, task-specific technique selection in cone-beam CT. Wang AS; Stayman JW; Otake Y; Vogt S; Kleinszig G; Khanna AJ; Gallia GL; Siewerdsen JH Med Phys; 2014 Jul; 41(7):071915. PubMed ID: 24989393 [TBL] [Abstract][Full Text] [Related]
29. Evaluation of hybrid SART + OS + TV iterative reconstruction algorithm for optical-CT gel dosimeter imaging. Du Y; Wang X; Xiang X; Wei Z Phys Med Biol; 2016 Dec; 61(24):8425-8439. PubMed ID: 27845916 [TBL] [Abstract][Full Text] [Related]
30. Iterative image reconstruction algorithm analysis for optical CT radiochromic gel dosimetry. Collins S; Ogilvy A; Hare W; Hilts M; Jirasek A Biomed Phys Eng Express; 2024 Apr; 10(3):. PubMed ID: 38579691 [No Abstract] [Full Text] [Related]
31. The adaptation and investigation of cone-beam CT reconstruction algorithms for horizontal rotation fixed-gantry scans of rabbits. Gardner M; Dillon O; Shieh CC; O'Brien R; Debrot E; Barber J; Ahern V; Bennett P; Heng SM; Corde S; Jackson M; Keall P Phys Med Biol; 2021 May; 66(10):. PubMed ID: 33878747 [TBL] [Abstract][Full Text] [Related]
32. Noise suppression in reconstruction of low-Z target megavoltage cone-beam CT images. Wang J; Robar J; Guan H Med Phys; 2012 Aug; 39(8):5111-7. PubMed ID: 22894436 [TBL] [Abstract][Full Text] [Related]
33. Effects of the penalty on the penalized weighted least-squares image reconstruction for low-dose CBCT. Ouyang L; Solberg T; Wang J Phys Med Biol; 2011 Sep; 56(17):5535-52. PubMed ID: 21813958 [TBL] [Abstract][Full Text] [Related]
34. Fast compressed sensing-based CBCT reconstruction using Barzilai-Borwein formulation for application to on-line IGRT. Park JC; Song B; Kim JS; Park SH; Kim HK; Liu Z; Suh TS; Song WY Med Phys; 2012 Mar; 39(3):1207-17. PubMed ID: 22380351 [TBL] [Abstract][Full Text] [Related]
35. Deep learning enables time-efficient soft tissue enhancement in CBCT: Proof-of-concept study for dentomaxillofacial applications. Ylisiurua S; Sipola A; Nieminen MT; Brix MAK Phys Med; 2024 Jan; 117():103184. PubMed ID: 38016216 [TBL] [Abstract][Full Text] [Related]
36. Low-dose cone-beam CT via raw counts domain low-signal correction schemes: Performance assessment and task-based parameter optimization (Part I: Assessment of spatial resolution and noise performance). Hayes JW; Gomez-Cardona D; Zhang R; Li K; Cruz-Bastida JP; Chen GH Med Phys; 2018 May; 45(5):1942-1956. PubMed ID: 29532483 [TBL] [Abstract][Full Text] [Related]
37. The effect of different image reconstruction techniques on pre-clinical quantitative imaging and dual-energy CT. Vaniqui A; Schyns LEJR; Almeida IP; van der Heyden B; Podesta M; Verhaegen F Br J Radiol; 2019 Mar; 92(1095):20180447. PubMed ID: 30394804 [TBL] [Abstract][Full Text] [Related]
38. Cone-beam breast CT using an offset detector: effect of detector offset and image reconstruction algorithm. Tseng HW; Karellas A; Vedantham S Phys Med Biol; 2022 Apr; 67(8):. PubMed ID: 35316793 [No Abstract] [Full Text] [Related]
39. Accuracy of dose calculation on iterative CBCT for head and neck radiotherapy. Washio H; Ohira S; Funama Y; Ueda Y; Isono M; Inui S; Miyazaki M; Teshima T Phys Med; 2021 Jun; 86():106-112. PubMed ID: 34102546 [TBL] [Abstract][Full Text] [Related]
40. Image quality in thoracic 4D cone-beam CT: a sensitivity analysis of respiratory signal, binning method, reconstruction algorithm, and projection angular spacing. Shieh CC; Kipritidis J; O'Brien RT; Kuncic Z; Keall PJ Med Phys; 2014 Apr; 41(4):041912. PubMed ID: 24694143 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]