These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

228 related articles for article (PubMed ID: 31455686)

  • 21. Valved Holding Chambers and In Vitro Metered Dose Inhaler Performance: Effects of Flow Rate and Inhalation Delay.
    Liu X; Guo C; Chowdhury B; Starke P; Limb S; Peri P; Schroeder A; Doub W
    J Aerosol Med Pulm Drug Deliv; 2017 Dec; 30(6):399-410. PubMed ID: 28846482
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Effects of Shake-Actuation Delay on Delivered Dose and Aerosol Characteristics of an Albuterol Suspension From a Pressurized Metered-Dose Inhaler.
    Qaqish R; Berlinski A
    Respir Care; 2021 Aug; 66(8):1315-1322. PubMed ID: 34103384
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Comparative in vitro performance of valved holding chambers with a budesonide/formoterol pressurized metered-dose inhaler.
    Chambers FE; Brown S; Ludzik AJ
    Allergy Asthma Proc; 2009; 30(4):424-32. PubMed ID: 19772764
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Effect of a Nebulizer Holding Chamber on Aerosol Delivery.
    Sarhan RM; Elberry AA; Abdelwahab NS; Rabea H; Salem MN; Abdelrahim ME
    Respir Care; 2018 Sep; 63(9):1125-1131. PubMed ID: 29789412
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Albuterol Delivery via Facial and Tracheostomy Route in a Model of a Spontaneously Breathing Child.
    Cooper B; Berlinski A
    Respir Care; 2015 Dec; 60(12):1749-58. PubMed ID: 26286736
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Assessing of low-tech solutions for aerosol delivery: Comparative performance study of manufactured versus homemade spacers.
    Moreau-Neidhardt M; Leclerc L; Grange J; Périnel S; Pourchez J
    Int J Pharm; 2023 Feb; 633():122652. PubMed ID: 36709833
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Comparative pharmacokinetics of salbutamol inhaled from a pressurized metered dose inhaler either alone or connected to a newly enhanced spacer design.
    Ammari WG; Oriquat GA; Sanders M
    Eur J Pharm Sci; 2020 Apr; 147():105304. PubMed ID: 32165316
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Considerations for Designing In Vitro Bioequivalence (IVBE) Studies for Pressurized Metered Dose Inhalers (pMDIs) with Spacer or Valved Holding Chamber (S/VHC) Add-on Devices.
    Sandell D; Mitchell JP
    J Aerosol Med Pulm Drug Deliv; 2015 Jun; 28(3):156-81. PubMed ID: 25089555
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Comparison between traditional and nontraditional add-on devices used with pressurised metered-dose inhalers.
    Nicola M; Soliman YMA; Hussein R; Saeed H; Abdelrahim M
    ERJ Open Res; 2020 Oct; 6(4):. PubMed ID: 33083443
    [TBL] [Abstract][Full Text] [Related]  

  • 30. A Rationale for Going Back to the Future: Use of Disposable Spacers for Pressurised Metered Dose Inhalers.
    Sanders M; Bruin R
    Pulm Med; 2015; 2015():176194. PubMed ID: 26491563
    [TBL] [Abstract][Full Text] [Related]  

  • 31. In vitro and clinical characterization of the valved holding chamber AeroChamber Plus
    Wachtel H; Nagel M; Engel M; El Azzi G; Sharma A; Suggett J
    Respir Med; 2018 Apr; 137():181-190. PubMed ID: 29605203
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Plastic bottles as spacers for a pressurized metered-dose inhaler: in vitro characteristics.
    Kissoon N; Teelucksingh S; Blake KV; Kesser B; Murphy SP; Geller D
    West Indian Med J; 2001 Sep; 50(3):189-93. PubMed ID: 11769021
    [TBL] [Abstract][Full Text] [Related]  

  • 33. [Chinese expert consensus on standardized inhaler device application in stable chronic airway diseases (2023)].
    Inhalation Therapy and Respiratory Rehabilitation Group, Respiratory Equipment Committee of China Association of Medical Equipment
    Zhonghua Jie He He Hu Xi Za Zhi; 2023 Nov; 46(11):1055-1067. PubMed ID: 37914418
    [TBL] [Abstract][Full Text] [Related]  

  • 34. In vitro evaluation of nonconventional accessory devices for pressurized metered-dose inhalers.
    Sheth P; Bertsch MD; Knapp CL; Myrdal PB
    Ann Allergy Asthma Immunol; 2014 Jul; 113(1):55-62. PubMed ID: 24814758
    [TBL] [Abstract][Full Text] [Related]  

  • 35. In vitro comparison of salbutamol hydrofluoroalkane (Airomir) metered dose inhaler aerosols inhaled during pediatric tidal breathing from five valved holding chambers.
    Finlay WH; Zuberbuhler P
    J Aerosol Med; 1999; 12(4):285-91. PubMed ID: 10724643
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Real-Time Analysis of the Respiratory Flow Through a Valved Holding Chamber.
    Curran E; Porée T; Rubin BK
    J Aerosol Med Pulm Drug Deliv; 2020 Aug; 33(4):205-213. PubMed ID: 32101063
    [No Abstract]   [Full Text] [Related]  

  • 37. Antistatic treatment and salbutamol dosing have variable effect on drug delivery of valved holding chambers.
    Csonka P; Lehtimäki L
    Pulm Pharmacol Ther; 2019 Dec; 59():101857. PubMed ID: 31678460
    [TBL] [Abstract][Full Text] [Related]  

  • 38. The evolution of spacers and valved holding chambers.
    Nikander K; Nicholls C; Denyer J; Pritchard J
    J Aerosol Med Pulm Drug Deliv; 2014 Aug; 27 Suppl 1():S4-23. PubMed ID: 25054481
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Delivery of salbutamol pressurized metered-dose inhaler administered via small-volume spacer devices in intubated, spontaneously breathing rabbits.
    Dubus JC; Rhem R; Monkman S; Dolovich M
    Pediatr Res; 2001 Sep; 50(3):384-9. PubMed ID: 11518826
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Optimal Inhalation Profile of Pressurized Metered Dry Powder Inhaler Using a Valved Holding Chamber: A Dynamic Analysis.
    Kondo T; Tanigaki T; Hibino M; Horiuchi S; Maeda K; Tobe S; Kamada R; Watanabe S
    J Aerosol Med Pulm Drug Deliv; 2024 Jun; 37(3):132-139. PubMed ID: 38648279
    [No Abstract]   [Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 12.