These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

168 related articles for article (PubMed ID: 31467789)

  • 1. Feature coupling photoacoustic computed tomography for joint reconstruction of initial pressure and sound speed
    Cai C; Wang X; Si K; Qian J; Luo J; Ma C
    Biomed Opt Express; 2019 Jul; 10(7):3447-3462. PubMed ID: 31467789
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Multi-segmented feature coupling for jointly reconstructing initial pressure and speed of sound in photoacoustic computed tomography.
    Deng K; Wang X; Cai C; Cui M; Zuo H; Luo J; Ma C
    J Biomed Opt; 2022 Jul; 27(7):. PubMed ID: 35778781
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Parameterized joint reconstruction of the initial pressure and sound speed distributions for photoacoustic computed tomography.
    Matthews TP; Poudel J; Li L; Wang LV; Anastasio MA
    SIAM J Imaging Sci; 2018; 11(2):1560-1588. PubMed ID: 30956749
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Joint Reconstruction of Absorbed Optical Energy Density and Sound Speed Distributions in Photoacoustic Computed Tomography: A Numerical Investigation.
    Huang C; Wang K; Schoonover RW; Wang LV; Anastasio MA
    IEEE Trans Comput Imaging; 2016 Jun; 2(2):136-149. PubMed ID: 29152545
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Adaptive dual-speed ultrasound and photoacoustic computed tomography.
    Zhang Y; Wang L
    Photoacoustics; 2022 Sep; 27():100380. PubMed ID: 35722271
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Adaptive photoacoustic computed tomography.
    Cui M; Zuo H; Wang X; Deng K; Luo J; Ma C
    Photoacoustics; 2021 Mar; 21():100223. PubMed ID: 33364162
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Joint reconstruction of the initial pressure and speed of sound distributions from combined photoacoustic and ultrasound tomography measurements.
    Matthews TP; Anastasio MA
    Inverse Probl; 2017 Dec; 33(12):. PubMed ID: 29713110
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Combined photoacoustic, pulse-echo laser ultrasound, and speed-of-sound imaging using integrating optical detection.
    Wurzinger G; Nuster R; Paltauf G
    J Biomed Opt; 2016 Aug; 21(8):86010. PubMed ID: 27548772
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Speed-of-sound compensated photoacoustic tomography for accurate imaging.
    Jose J; Willemink RG; Steenbergen W; Slump CH; van Leeuwen TG; Manohar S
    Med Phys; 2012 Dec; 39(12):7262-71. PubMed ID: 23231277
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Novel reconstruction algorithm of magnetoacoustic tomography based on ring transducer array for acoustic speed inhomogeneous tissues.
    Wang L; Liu G; Chen S; Chen X; Ma X; Xia H
    Med Phys; 2020 Aug; 47(8):3533-3544. PubMed ID: 32343838
    [TBL] [Abstract][Full Text] [Related]  

  • 11. An image reconstruction method for endoscopic photoacoustic tomography in tissues with heterogeneous sound speed.
    Zheng S; Yixuan J
    Comput Biol Med; 2019 Jul; 110():15-28. PubMed ID: 31103813
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Image reconstruction with the Heaviside equation in photoacoustic tomography accounting for dispersive acoustic media.
    Moock VM; Gutiérrez-Reyes EA; García-Segundo C
    J Biomed Opt; 2018 Jul; 23(7):1-12. PubMed ID: 30027712
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Image reconstruction with uncertainty quantification in photoacoustic tomography.
    Tick J; Pulkkinen A; Tarvainen T
    J Acoust Soc Am; 2016 Apr; 139(4):1951. PubMed ID: 27106341
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Modelling of errors due to speed of sound variations in photoacoustic tomography using a Bayesian framework.
    Tick J; Pulkkinen A; Tarvainen T
    Biomed Phys Eng Express; 2019 Nov; 6(1):015003. PubMed ID: 33438591
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Video-rate full-ring ultrasound and photoacoustic computed tomography with real-time sound speed optimization.
    Zhang Y; Wang L
    Biomed Opt Express; 2022 Aug; 13(8):4398-4413. PubMed ID: 36032563
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A new acoustic lens material for large area detectors in photoacoustic breast tomography.
    Xia W; Piras D; van Hespen JC; Steenbergen W; Manohar S
    Photoacoustics; 2013 May; 1(2):9-18. PubMed ID: 25302146
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A survey of computational frameworks for solving the acoustic inverse problem in three-dimensional photoacoustic computed tomography.
    Poudel J; Lou Y; Anastasio MA
    Phys Med Biol; 2019 Jul; 64(14):14TR01. PubMed ID: 31067527
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Resolution Limits in Photoacoustic Imaging Caused by Acoustic Attenuation.
    Burgholzer P; Bauer-Marschallinger J; Reitinger B; Berer T
    J Imaging; 2019 Jan; 5(1):. PubMed ID: 34465707
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Quantitative photoacoustic tomography: modeling and inverse problems.
    Tarvainen T; Cox B
    J Biomed Opt; 2024 Jan; 29(Suppl 1):S11509. PubMed ID: 38125717
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Automatic sound speed selection in photoacoustic image reconstruction using an autofocus approach.
    Treeby BE; Varslot TK; Zhang EZ; Laufer JG; Beard PC
    J Biomed Opt; 2011 Sep; 16(9):090501. PubMed ID: 21950905
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.