BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

165 related articles for article (PubMed ID: 31471756)

  • 1. Numerical models of valve-in-valve implantation: effect of intentional leaflet laceration on the anchorage.
    Yaakobovich H; Plitman Mayo R; Zaretsky U; Finkelstein A; Marom G
    Biomech Model Mechanobiol; 2020 Apr; 19(2):415-426. PubMed ID: 31471756
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The effect of clinically recommended Evolut sizes on anchorage forces after BASILICA.
    Yaakobovich H; Plitman Mayo R; Zaretsky U; Finkelstein A; Weiss D; Marom G
    J Biomech; 2021 Mar; 118():110303. PubMed ID: 33601185
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Balloon-Augmented Leaflet Modification With Bioprosthetic or Native Aortic Scallop Intentional Laceration to Prevent Iatrogenic Coronary Artery Obstruction and Laceration of the Anterior Mitral Leaflet to Prevent Outflow Obstruction: Benchtop Validation and First In-Man Experience.
    Perdoncin E; Bruce CG; Babaliaros VC; Yildirim DK; Depta JP; McCabe JM; Gleason PT; Xie J; Grubb KJ; Paone G; Kohli K; Kamioka N; Khan JM; Rogers T; Lederman RJ; Greenbaum AB
    Circ Cardiovasc Interv; 2021 Nov; 14(11):e011028. PubMed ID: 34674556
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Impact of Leaflet Laceration on Transcatheter Aortic Valve-in-Valve Washout: BASILICA to Solve Neosinus and Sinus Stasis.
    Hatoum H; Maureira P; Lilly S; Dasi LP
    JACC Cardiovasc Interv; 2019 Jul; 12(13):1229-1237. PubMed ID: 31272669
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Transcatheter Laceration of Aortic Leaflets to Prevent Coronary Obstruction During Transcatheter Aortic Valve Replacement: Concept to First-in-Human.
    Khan JM; Dvir D; Greenbaum AB; Babaliaros VC; Rogers T; Aldea G; Reisman M; Mackensen GB; Eng MHK; Paone G; Wang DD; Guyton RA; Devireddy CM; Schenke WH; Lederman RJ
    JACC Cardiovasc Interv; 2018 Apr; 11(7):677-689. PubMed ID: 29622147
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Systematic use of intentional leaflet laceration to prevent TAVI-induced coronary obstruction: feasibility and early clinical outcomes of the BASILICA technique.
    Kitamura M; Majunke N; Holzhey D; Desch S; Bani Hani A; Krieghoff C; Gutberlet M; Protsyk V; Ender J; Borger MA; Dvir D; Thiele H; Abdel-Wahab M
    EuroIntervention; 2020 Oct; 16(8):682-690. PubMed ID: 32597392
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Prevention of coronary obstruction in patients at risk undergoing transcatheter aortic valve implantation: the Hamburg BASILICA experience.
    Westermann D; Ludwig S; Kalbacher D; Spink C; Linder M; Bhadra OD; Nikorowitsch J; Waldschmidt L; Demal T; Voigtländer L; Schaefer A; Seiffert M; Pecha S; Schofer N; Greenbaum AB; Reichenspurner H; Blankenberg S; Conradi L; Schirmer J
    Clin Res Cardiol; 2021 Dec; 110(12):1900-1911. PubMed ID: 34156524
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Bioprosthetic Aortic Scallop Intentional Laceration to prevent Iatrogenic Coronary Artery obstruction (BASILICA) in valve-in-valve Transcatheter Aortic Valve Implantation (ViV-TAVI): First experience in Poland.
    Jędrzejczyk S; Rymuza B; Ścisło P; Grodecki K; Pędzich-Placha E; Grabowski M; Kochman J; Huczek Z
    Kardiol Pol; 2022; 80(12):1266-1267. PubMed ID: 36161589
    [No Abstract]   [Full Text] [Related]  

  • 9. Bioprosthetic Valve Leaflet Displacement During Valve-in-Valve Intervention: An Ex Vivo Bench Study.
    Hensey M; Sellers S; Sathananthan J; Lai A; Landes U; Alkhodair A; McManus B; Cheung A; Wood D; Blanke P; Leipsic J; Ye J; Webb J
    JACC Cardiovasc Interv; 2020 Mar; 13(6):667-678. PubMed ID: 32113932
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Bioprosthetic aortic valve leaflet disruption with high energy electrocautery to prevent coronary artery obstruction during valve-in-valve transcatheter aortic valve replacement.
    Nelson BC; Chadderdon S; Song H; Zahr FE
    Catheter Cardiovasc Interv; 2019 Jan; 93(1):164-168. PubMed ID: 30298684
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The Use of BASILICA Technique to Prevent Coronary Obstruction in a TAVI-TAVI Procedure.
    Tagliari AP; Petersen Saadi R; Medronha EF; Keller Saadi E
    J Clin Med; 2021 Nov; 10(23):. PubMed ID: 34884239
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Bioprosthetic or native aortic scallop intentional laceration to prevent iatrogenic coronary artery obstruction technique in transcatheter aortic valve-in-valve procedures: a single-center initial experience.
    Tagliari AP; Miura M; Gavazzoni M; Haager PK; Russo G; Pozzoli A; Zuber M; Jörg L; Rickli H; Gennari M; Maisano F; Taramasso M
    J Cardiovasc Med (Hagerstown); 2021 Mar; 22(3):212-221. PubMed ID: 32890234
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Echocardiographic Guidance of Intentional Leaflet Laceration prior to Transcatheter Aortic Valve Replacement: A Structured Approach to the Bioprosthetic or Native Aortic Scallop Intentional Laceration to Prevent Iatrogenic Coronary Artery Obstruction Procedure.
    Protsyk V; Meineri M; Kitamura M; Flo Forner A; Holzhey D; Thiele H; Mackensen GB; Dvir D; Abdel-Wahab M; Ender JK
    J Am Soc Echocardiogr; 2021 Jun; 34(6):676-689. PubMed ID: 33675944
    [TBL] [Abstract][Full Text] [Related]  

  • 14. BASILICA Trial: One-Year Outcomes of Transcatheter Electrosurgical Leaflet Laceration to Prevent TAVR Coronary Obstruction.
    Khan JM; Greenbaum AB; Babaliaros VC; Dvir D; Reisman M; McCabe JM; Satler L; Waksman R; Eng MH; Paone G; Chen MY; Bruce CG; Stine AM; Tian X; Rogers T; Lederman RJ
    Circ Cardiovasc Interv; 2021 May; 14(5):e010238. PubMed ID: 34003670
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Safeguards and pitfalls for Bioprosthetic or Native Aortic Scallop Intentional Laceration to Prevent Iatrogenic Coronary Artery Obstruction during transcatheter aortic valve replacement-the BASILICA technique.
    Bruce CG; Greenbaum AB; Babaliaros VC; Rogers T; Lederman RJ; Khan JM
    Ann Cardiothorac Surg; 2021 Sep; 10(5):700-707. PubMed ID: 34733702
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Bioprosthetic Aortic Scallop Intentional Laceration to prevent Iatrogenic Coronary Artery obstruction (BASILICA) during transcatheter aortic valve-in-valve implantation with bioprosthetic valve fracturing via the transcaval access.
    Lanz J; Pilgrim T; Greenbaum AB; Windecker S
    EuroIntervention; 2018 Oct; 14(8):884-885. PubMed ID: 30020077
    [No Abstract]   [Full Text] [Related]  

  • 17. Risk Assessment of Coronary Obstruction During Transcatheter Aortic Valve Replacement: Insights From Post-BASILICA Computed Tomography.
    Kitamura M; Wilde J; Dumpies O; Richter I; Obradovic D; Krieghoff C; Gohmann RF; Majunke N; Desch S; Gutberlet M; Borger M; Marwan M; Thiele H; Holzhey D; Abdel-Wahab M
    JACC Cardiovasc Interv; 2022 Mar; 15(5):496-507. PubMed ID: 35272774
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Numerical models for assessing the risk of leaflet thrombosis post-transcatheter aortic valve-in-valve implantation.
    Plitman Mayo R; Yaakobovich H; Finkelstein A; Shadden SC; Marom G
    R Soc Open Sci; 2020 Dec; 7(12):201838. PubMed ID: 33489295
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Use of transesophageal echocardiography for transcatheter valve-in-valve implantation for patients with prior bioprosthetic surgical aortic, mitral, tricuspid, and pulmonic valves.
    Bhargava AA; Shekiladze N; Xie J; Kini A; Gleason PT; Lerakis S
    Ann Cardiothorac Surg; 2021 Sep; 10(5):605-620. PubMed ID: 34733688
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Pachyderm-Shape Guiding Catheters to Simplify BASILICA Leaflet Traversal.
    Lisko JC; Babaliaros VC; Lederman RJ; Khan JM; Rogers T; Greenbaum AB
    Cardiovasc Revasc Med; 2019 Sep; 20(9):782-785. PubMed ID: 31257172
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.