These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

152 related articles for article (PubMed ID: 31477247)

  • 1. Pre-heating effects on extrusion force, stickiness and packability of resin-based composite.
    Yang J; Silikas N; Watts DC
    Dent Mater; 2019 Nov; 35(11):1594-1602. PubMed ID: 31477247
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Pre-heating time and exposure duration: Effects on post-irradiation properties of a thermo-viscous resin-composite.
    Yang J; Silikas N; Watts DC
    Dent Mater; 2020 Jun; 36(6):787-793. PubMed ID: 32386715
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Polymerization and shrinkage kinetics and fracture toughness of bulk-fill resin-composites.
    Yang J; Silikas N; Watts DC
    Dent Mater; 2022 Dec; 38(12):1934-1941. PubMed ID: 38709119
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A method for assessing force/work parameters for stickiness of unset resin-composites.
    Kaleem M; Satterthwaite JD; Watts DC
    Dent Mater; 2011 Aug; 27(8):805-10. PubMed ID: 21600644
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Viscosity and stickiness of dental resin composites at elevated temperatures.
    Loumprinis N; Maier E; Belli R; Petschelt A; Eliades G; Lohbauer U
    Dent Mater; 2021 Mar; 37(3):413-422. PubMed ID: 33353736
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Effect of pre-heating methods and devices on the mechanical properties, post-gel shrinkage, and shrinkage stress of bulk-fill materials.
    Hordones Ribeiro MT; Felipe de Bragança G; Sales Oliveira LR; Lourenço Braga SS; Quirino de Oliveira HL; Price RB; Soares CJ
    J Mech Behav Biomed Mater; 2023 Feb; 138():105605. PubMed ID: 36516543
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effect of filler particle size and morphology on force/work parameters for stickiness of unset resin-composites.
    Kaleem M; Satterthwaite JD; Watts DC
    Dent Mater; 2009 Dec; 25(12):1585-92. PubMed ID: 19744705
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Stiffness of uncured resin-composites assessed via cavity-packing forces.
    Kaleem M; Watts DC
    Dent Mater; 2016 Sep; 32(9):e199-203. PubMed ID: 27364383
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Spatio-temporal temperature fields generated coronally with bulk-fill resin composites: A thermography study.
    Yang J; Algamaiah H; Watts DC
    Dent Mater; 2021 Aug; 37(8):1237-1247. PubMed ID: 34144795
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Pre-heating of high-viscosity bulk-fill resin composites: effects on shrinkage force and monomer conversion.
    Tauböck TT; Tarle Z; Marovic D; Attin T
    J Dent; 2015 Nov; 43(11):1358-64. PubMed ID: 26232610
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Effect of filler particles morphology of resin-composites on cavity packing force for repeated condensation.
    Kaleem M; Watts DC
    Dent Mater J; 2017 May; 36(3):340-347. PubMed ID: 28367908
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Effect of exposure time and pre-heating on the conversion degree of conventional, bulk-fill, fiber reinforced and polyacid-modified resin composites.
    Lempel E; Őri Z; Szalma J; Lovász BV; Kiss A; Tóth Á; Kunsági-Máté S
    Dent Mater; 2019 Feb; 35(2):217-228. PubMed ID: 30503020
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The effect of resin composite pre-heating on monomer conversion and polymerization shrinkage.
    Lohbauer U; Zinelis S; Rahiotis C; Petschelt A; Eliades G
    Dent Mater; 2009 Apr; 25(4):514-9. PubMed ID: 19081616
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Stickiness prior to setting of some light cured resin-composites.
    Al-Sharaa KA; Watts DC
    Dent Mater; 2003 May; 19(3):182-7. PubMed ID: 12628429
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Stickiness of dental resin composite materials to steel, dentin and bonded dentin.
    Ertl K; Graf A; Watts D; Schedle A
    Dent Mater; 2010 Jan; 26(1):59-66. PubMed ID: 19837452
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Conversion kinetics of rapid photo-polymerized resin composites.
    Algamaiah H; Silikas N; Watts DC
    Dent Mater; 2020 Oct; 36(10):1266-1274. PubMed ID: 32798046
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effect of temperature on post-cure polymerization of bulk-fill composites.
    Par M; Gamulin O; Marovic D; Klaric E; Tarle Z
    J Dent; 2014 Oct; 42(10):1255-60. PubMed ID: 25132366
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Degree of conversion of bulk-fill compared to conventional resin-composites at two time intervals.
    Alshali RZ; Silikas N; Satterthwaite JD
    Dent Mater; 2013 Sep; 29(9):e213-7. PubMed ID: 23845799
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Effect of Pre-Heating on the Monomer Elution and Porosity of Conventional and Bulk-Fill Resin-Based Dental Composites.
    Dunavári E; Berta G; Kiss T; Szalma J; Fráter M; Böddi K; Lempel E
    Int J Mol Sci; 2022 Dec; 23(24):. PubMed ID: 36555828
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Polymerization kinetics and impact of post polymerization on the Degree of Conversion of bulk-fill resin-composite at clinically relevant depth.
    Al-Ahdal K; Ilie N; Silikas N; Watts DC
    Dent Mater; 2015 Oct; 31(10):1207-13. PubMed ID: 26296813
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.