These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

122 related articles for article (PubMed ID: 31479771)

  • 1. Anchored Transponder Guided Lung Radiation Therapy.
    Dobelbower MC; Popple RA; Minnich DJ; Nader DA; Zimmerman F; Paris GE; Herth FJF; Gompelmann D; Roeder FF; Parikh PJ; McDonald AM
    Pract Radiat Oncol; 2020; 10(1):e37-e44. PubMed ID: 31479771
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Longitudinal assessment of anchored transponder migration following lung stereotactic body radiation therapy.
    McDonald AM; Colvin T; Boggs DH; Spencer SA; Popple RA; Clayton R; Minnich D; Dobelbower MC
    J Appl Clin Med Phys; 2019 Jan; 20(1):17-22. PubMed ID: 30387242
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Real-time tumor tracking in the lung using an electromagnetic tracking system.
    Shah AP; Kupelian PA; Waghorn BJ; Willoughby TR; Rineer JM; MaƱon RR; Vollenweider MA; Meeks SL
    Int J Radiat Oncol Biol Phys; 2013 Jul; 86(3):477-83. PubMed ID: 23523325
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Bronchoscopic implantation of a novel wireless electromagnetic transponder in the canine lung: a feasibility study.
    Mayse ML; Parikh PJ; Lechleiter KM; Dimmer S; Park M; Chaudhari A; Talcott M; Low DA; Bradley JD
    Int J Radiat Oncol Biol Phys; 2008 Sep; 72(1):93-8. PubMed ID: 18394817
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Electromagnetic Transponder Based Tracking and Gating in the Radiotherapeutic Treatment of Thoracic Malignancies.
    Boggs DH; Popple R; McDonald A; Minnich D; Willey CD; Spencer S; Shen S; Dobelbower MC
    Pract Radiat Oncol; 2019 Nov; 9(6):456-464. PubMed ID: 31283991
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A Prospective Study on Deep Inspiration Breath Hold Thoracic Radiation Therapy Guided by Bronchoscopically Implanted Electromagnetic Transponders.
    Meng YJ; Mankuzhy NP; Chawla M; Lee RP; Yorke ED; Zhang Z; Gelb E; Lim SB; Cuaron JJ; Wu AJ; Simone CB; Gelblum DY; Lovelock DM; Harris W; Rimner A
    Cancers (Basel); 2024 Apr; 16(8):. PubMed ID: 38672616
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Feasibility of electromagnetic transponder use to monitor inter- and intrafractional motion in locally advanced pancreatic cancer patients.
    Shinohara ET; Kassaee A; Mitra N; Vapiwala N; Plastaras JP; Drebin J; Wan F; Metz JM
    Int J Radiat Oncol Biol Phys; 2012 Jun; 83(2):566-73. PubMed ID: 22099029
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Multimodality guidance for accurate bronchoscopic insertion of fiducial markers.
    Steinfort DP; Siva S; Kron T; Chee RR; Ruben JD; Ball DL; Irving LB
    J Thorac Oncol; 2015 Feb; 10(2):324-30. PubMed ID: 25616177
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Can bronchoscopically implanted anchored electromagnetic transponders be used to monitor tumor position and lung inflation during deep inspiration breath-hold lung radiotherapy?
    Harris W; Yorke E; Li H; Czmielewski C; Chawla M; Lee RP; Hotca-Cho A; McKnight D; Rimner A; Lovelock DM
    Med Phys; 2022 Apr; 49(4):2621-2630. PubMed ID: 35192211
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Prostate tumor alignment and continuous, real-time adaptive radiation therapy using electromagnetic fiducials: clinical and cost-utility analyses.
    Quigley MM; Mate TP; Sylvester JE
    Urol Oncol; 2009; 27(5):473-82. PubMed ID: 18625565
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Feasibility of insertion/implantation of 2.0-mm-diameter gold internal fiducial markers for precise setup and real-time tumor tracking in radiotherapy.
    Shirato H; Harada T; Harabayashi T; Hida K; Endo H; Kitamura K; Onimaru R; Yamazaki K; Kurauchi N; Shimizu T; Shinohara N; Matsushita M; Dosaka-Akita H; Miyasaka K
    Int J Radiat Oncol Biol Phys; 2003 May; 56(1):240-7. PubMed ID: 12694845
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Electromagnetic navigational bronchoscopy-guided fiducial markers for lung stereotactic body radiation therapy: analysis of safety, feasibility, and interfraction stability.
    Nabavizadeh N; Zhang J; Elliott DA; Tanyi JA; Thomas CR; Fuss M; Deffebach M
    J Bronchology Interv Pulmonol; 2014 Apr; 21(2):123-30. PubMed ID: 24739685
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Ultrasound-guided transrectal implantation of fiducial markers for image-guided radiotherapy of prostate cancer without local anesthesia: Patient-reported gastrointestinal-genitourinary system complications and pain.
    Sen CA
    J Cancer Res Ther; 2021; 17(2):353-357. PubMed ID: 34121677
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Assessment of planning target volume margins for intensity-modulated radiotherapy of the prostate gland: role of daily inter- and intrafraction motion.
    Tanyi JA; He T; Summers PA; Mburu RG; Kato CM; Rhodes SM; Hung AY; Fuss M
    Int J Radiat Oncol Biol Phys; 2010 Dec; 78(5):1579-85. PubMed ID: 20472357
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Preliminary clinical experience with Calypso anchored beacons for tumor tracking in lung SBRT.
    Sarkar V; Szegedi M; Paxton A; Nelson G; Rassiah-Szegedi P; Reddy CB; Tao R; Hitchcock YJ; Kokeny KE; Salter BJ
    Med Phys; 2020 Sep; 47(9):4407-4415. PubMed ID: 32463925
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Fiducial marker placement via conventional or electromagnetic navigation bronchoscopy (ENB): an interdisciplinary approach to the curative management of lung cancer.
    Hagmeyer L; Priegnitz C; Kocher M; Schilcher B; Budach W; Treml M; Stieglitz S; Randerath W
    Clin Respir J; 2016 May; 10(3):291-7. PubMed ID: 25308297
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Fiducial-based translational localization accuracy of electromagnetic tracking system and on-board kilovoltage imaging system.
    Santanam L; Malinowski K; Hubenshmidt J; Dimmer S; Mayse ML; Bradley J; Chaudhari A; Lechleiter K; Goddu SK; Esthappan J; Mutic S; Low DA; Parikh P
    Int J Radiat Oncol Biol Phys; 2008 Mar; 70(3):892-9. PubMed ID: 18262100
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Convex Probe EBUS-guided Fiducial Placement for Malignant Central Lung Lesions.
    Majid A; Palkar A; Kheir F; Alape D; Fernandez-Bussy S; Aronovitz J; Guerrero J; Gangadharan S; Kent M; Whyte R; Folch E
    J Bronchology Interv Pulmonol; 2018 Oct; 25(4):283-289. PubMed ID: 29939888
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Practical Assessment of Bronchoscopically Inserted Fiducial Markers for Image Guidance in Stereotactic Lung Radiotherapy.
    Jackson P; Steinfort DP; Kron T; Siva S
    J Thorac Oncol; 2016 Aug; 11(8):1363-1368. PubMed ID: 27130830
    [TBL] [Abstract][Full Text] [Related]  

  • 20. CT-guided core biopsy and percutaneous fiducial seed placement in the lung: can these procedures be combined without an increase in complication rate or decrease in technical success?
    Mendiratta-Lala M; Sheiman R; Brook OR; Gourtsoyianni S; Mahadevan A; Siewert B
    Eur J Radiol; 2014 Apr; 83(4):720-5. PubMed ID: 24534120
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]