BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

165 related articles for article (PubMed ID: 31493955)

  • 1. 2-D Shear Wave Elastography for Focal Lesions in Liver Phantoms: Effects of Background Stiffness, Depth and Size of Focal Lesions on Stiffness Measurement.
    Hwang JA; Jeong WK; Song KD; Kang KA; Lim HK
    Ultrasound Med Biol; 2019 Dec; 45(12):3261-3268. PubMed ID: 31493955
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Assessing Hepatic Fibrosis Using 2-D Shear Wave Elastography in Patients with Liver Tumors: A Prospective Single-Center Study.
    Huang Z; Zheng W; Zhang YJ; Xu L; Chen JB; Chen JC; Chen MS; Zhou Z
    Ultrasound Med Biol; 2017 Nov; 43(11):2522-2529. PubMed ID: 28807448
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Normal liver stiffness in healthy adults assessed by real-time shear wave elastography and factors that influence this method.
    Huang Z; Zheng J; Zeng J; Wang X; Wu T; Zheng R
    Ultrasound Med Biol; 2014 Nov; 40(11):2549-55. PubMed ID: 25282481
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of four different Shear Wave Elastography platforms according to abdominal wall thickness in liver fibrosis evaluation: a phantom study.
    Lee SM; Chang W; Kang HJ; Ahn SJ; Lee JH; Lee JM
    Med Ultrason; 2019 Feb; 21(1):22-29. PubMed ID: 30779827
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Performance evaluation of commercial and non-commercial shear wave elastography implementations for vascular applications.
    Pruijssen JT; Schreuder FHBM; Wilbers J; Kaanders JHAM; de Korte CL; Hansen HHG
    Ultrasonics; 2024 May; 140():107312. PubMed ID: 38599075
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Motion effects on the measurement of stiffness on ultrasound shear wave elastography: a moving liver fibrosis phantom study.
    Shin HJ; Kim MJ; Yoon CS; Lee K; Lee KS; Park JC; Lee MJ; Yoon H
    Med Ultrason; 2018 Feb; 1(1):14-20. PubMed ID: 29400362
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Influence of measurement depth on the stiffness assessment of healthy liver with real-time shear wave elastography.
    Wang CZ; Zheng J; Huang ZP; Xiao Y; Song D; Zeng J; Zheng HR; Zheng RQ
    Ultrasound Med Biol; 2014 Mar; 40(3):461-9. PubMed ID: 24361224
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Shear Wave Elastography of Focal Liver Lesion: Intraobserver Reproducibility and Elasticity Characterization.
    Park HS; Kim YJ; Yu MH; Jung SI; Jeon HJ
    Ultrasound Q; 2015 Dec; 31(4):262-71. PubMed ID: 26086459
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Ultrasound Shear Wave Elastography for Liver Disease. A Critical Appraisal of the Many Actors on the Stage.
    Piscaglia F; Salvatore V; Mulazzani L; Cantisani V; Schiavone C
    Ultraschall Med; 2016 Feb; 37(1):1-5. PubMed ID: 26871407
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Two-dimensional shear-wave elastography: a new method comparable to acoustic radiation force impulse imaging?
    Schellhaas B; Strobel D; Wildner D; Goertz RS; Neurath MF; Pfeifer L
    Eur J Gastroenterol Hepatol; 2017 Jun; 29(6):723-729. PubMed ID: 28118179
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Performance of 2-D shear wave elastography in liver fibrosis assessment compared with serologic tests and transient elastography in clinical routine.
    Bota S; Paternostro R; Etschmaier A; Schwarzer R; Salzl P; Mandorfer M; Kienbacher C; Ferlitsch M; Reiberger T; Trauner M; Peck-Radosavljevic M; Ferlitsch A
    Ultrasound Med Biol; 2015 Sep; 41(9):2340-9. PubMed ID: 26004669
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Performance of two--dimensional ultrasound shear wave elastography: reference values of normal liver stiffness in children.
    Galina P; Alexopoulou E; Zellos A; Grigoraki V; Siahanidou T; Kelekis NL; Zarifi M
    Pediatr Radiol; 2019 Jan; 49(1):91-98. PubMed ID: 30267166
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Reproducibility of shear wave elastography among operators, machines, and probes in an elasticity phantom.
    Alrashed AI; Alfuraih AM
    Ultrasonography; 2021 Jan; 40(1):158-166. PubMed ID: 32660213
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Evaluation of liver parenchyma stiffness in patients with liver tumours: optimal strategy for shear wave elastography.
    Zheng W; Zhou ZG; Wong CH; Pei XQ; Zhuang SL; Li Q; Chen MS; Li AH; Zhang FJ
    Eur Radiol; 2019 Mar; 29(3):1479-1488. PubMed ID: 30105408
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Reliability and applicability of two-dimensional shear-wave elastography for the evaluation of liver stiffness.
    Varbobitis IC; Siakavellas SI; Koutsounas IS; Karagiannakis DS; Ioannidou P; Papageorgiou MV; Pavlopoulou ID; Schizas D; Bamias G; Vlachogiannakos I; Ladas SD; Papatheodoridis GV
    Eur J Gastroenterol Hepatol; 2016 Oct; 28(10):1204-9. PubMed ID: 27340898
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparison of Two-Dimensional Shear Wave Elastography and Real-Time Tissue Elastography for Assessing Liver Fibrosis in Chronic Hepatitis B.
    Wu T; Wang P; Zhang T; Zheng J; Li S; Zeng J; Kudo M; Zheng R
    Dig Dis; 2016; 34(6):640-649. PubMed ID: 27750231
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A New Criterion for Shear Wave Elastometric Assessment Using Modulus of Stiffness Difference between Object and Environment.
    Demin IY; Rykhtik PI; Spivak АE; Safonov DV
    Sovrem Tekhnologii Med; 2022; 14(5):5-13. PubMed ID: 37181832
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Interplatform reproducibility of liver and spleen stiffness measured with MR elastography.
    Yasar TK; Wagner M; Bane O; Besa C; Babb JS; Kannengiesser S; Fung M; Ehman RL; Taouli B
    J Magn Reson Imaging; 2016 May; 43(5):1064-72. PubMed ID: 26469708
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Shear wave elastography for liver stiffness measurement in clinical sonographic examinations: evaluation of intraobserver reproducibility, technical failure, and unreliable stiffness measurements.
    Yoon JH; Lee JM; Han JK; Choi BI
    J Ultrasound Med; 2014 Mar; 33(3):437-47. PubMed ID: 24567455
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Arterial Stiffness Estimation by Shear Wave Elastography: Validation in Phantoms with Mechanical Testing.
    Maksuti E; Widman E; Larsson D; Urban MW; Larsson M; Bjällmark A
    Ultrasound Med Biol; 2016 Jan; 42(1):308-21. PubMed ID: 26454623
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.