These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
128 related articles for article (PubMed ID: 31497098)
21. Microcatheter Re-Shaping Using Fusion Image in Coil Embolization: A Technical Note. Hirayama A; Srivatanakul K; Shigematsu H; Yokota K; Sorimachi T; Matsumae M J Neuroendovasc Ther; 2021; 15(11):755-761. PubMed ID: 37502268 [TBL] [Abstract][Full Text] [Related]
22. Virtual simulation with AneuShape™ software for microcatheter shaping in intracranial aneurysm coiling: a validation study. Wu ZB; Zeng Y; Zhang HQ; Shu K; Li GH; Xiang JP; Lei T; Zhu MX Front Neurol; 2023; 14():1095266. PubMed ID: 37181546 [TBL] [Abstract][Full Text] [Related]
23. Intra-aneurysmal microcatheter looping technique for stent-assisted embolization of complex intracranial aneurysms. Wang CC; Lv N; Feng ZZ; Li ZF; Zhao R; Li Q; Liu JM; Huang QH Interv Neuroradiol; 2015 Oct; 21(5):580-4. PubMed ID: 26179063 [TBL] [Abstract][Full Text] [Related]
24. Shapability, memory, and luminal changes in microcatheters after steam shaping: a comparison of 11 different microcatheters. Kiyosue H; Hori Y; Matsumoto S; Okahara M; Tanoue S; Sagara Y; Mori H AJNR Am J Neuroradiol; 2005; 26(10):2610-6. PubMed ID: 16286410 [TBL] [Abstract][Full Text] [Related]
25. Three-dimensional shaping technique for coil placement using the steam-shaped microcatheter for ruptured blood blister-like aneurysm. Shinoda N; Mori M; Tamura S; Korosue K; Kose S; Kohmura E Neurochirurgie; 2018 Jun; 64(3):216-218. PubMed ID: 29907359 [TBL] [Abstract][Full Text] [Related]
26. Navigating complexity: a comprehensive review of microcatheter shaping techniques in endovascular aneurysm embolization. Liu C; Wu X; Hu X; Wu L; Guo K; Zhou S; Fang B Front Neurol; 2023; 14():1245817. PubMed ID: 37928161 [TBL] [Abstract][Full Text] [Related]
27. Distal-tip shape-consistency testing of steam-shaped microcatheters suitable for cerebral aneurysm coil placement. Abe T; Hirohata M; Tanaka N; Uchiyama Y; Fujimoto K; Fujimura N; Norbash AM; Hayabuchi N AJNR Am J Neuroradiol; 2004; 25(6):1058-61. PubMed ID: 15205148 [TBL] [Abstract][Full Text] [Related]
28. Modified balloon assisted coil embolization for the treatment of intracranial and cervical arterial aneurysms using coaxial dual lumen balloon microcatheters: initial experience. Jagadeesan BD; Siddiq F; Grande AW; Tummala RP J Neurointerv Surg; 2014 Nov; 6(9):704-7. PubMed ID: 24153339 [TBL] [Abstract][Full Text] [Related]
29. Tailor-made shaping of microcatheters using three-dimensional printed vessel models for endovascular coil embolization. Ishibashi T; Takao H; Suzuki T; Yuki I; Kaku S; Kan I; Nishimura K; Suzuki T; Watanabe M; Karagiozov K; Murayama Y Comput Biol Med; 2016 Oct; 77():59-63. PubMed ID: 27521515 [TBL] [Abstract][Full Text] [Related]
30. Microcatheter shaping using intravascular placement during intracranial aneurysm coiling. Yamaguchi S; Ito O; Koyanagi Y; Iwaki K; Matsukado K Interv Neuroradiol; 2017 Jun; 23(3):249-254. PubMed ID: 28166669 [TBL] [Abstract][Full Text] [Related]
31. Coil Embolization for Ruptured Cerebral Aneurysms of 2x3 mm Diameter. Tone O; Tomita H; Tamaki M; Akimoto H; Shigeta K; Sampetrean O; Fujii M Interv Neuroradiol; 2006 Jan; 12(Suppl 1):97-100. PubMed ID: 20569610 [TBL] [Abstract][Full Text] [Related]
32. Computer-Assisted Microcatheter Shaping for Intracranial Aneurysm Embolization. Yang H; Xu L; Li Y; Jiang H; Ni W; Gu Y Brain Sci; 2023 Aug; 13(9):. PubMed ID: 37759874 [TBL] [Abstract][Full Text] [Related]
33. Microcatheter looping technique for coil embolization of complex configuration middle cerebral artery aneurysms. Cho YD; Kang HS; Kim JE; Son YJ; Lee JY; Lee SJ; Seo JH; Han MH Neurosurgery; 2012 Dec; 71(6):1185-91; discussion 1191. PubMed ID: 23037814 [TBL] [Abstract][Full Text] [Related]
35. Experimental study of coil delivery wire insertion force in intracranial aneurysm embolization: force discrepancy generated inside the microcatheter through that coil delivery wire passes. Shintai K; Matsubara N; Izumi T; Miyachi S; Yamada H; Marui N; Wakabayashi T Nagoya J Med Sci; 2019 May; 81(2):217-225. PubMed ID: 31239590 [TBL] [Abstract][Full Text] [Related]
36. Simmons Angled microguidewire INsertion to the Target (SAINT) technique in neuroendovascular therapy. Ryu B; Sato S; Inoue T; Okada Y; Niimi Y J Neuroradiol; 2021 Sep; 48(5):400-403. PubMed ID: 31563587 [TBL] [Abstract][Full Text] [Related]
37. Use of Triple Microcatheters for Endovascular Treatment of Wide-Necked Intracranial Aneurysms: A Single Center Experience. Cho YD; Rhim JK; Kang HS; Park JJ; Jeon JP; Kim JE; Cho WS; Han MH Korean J Radiol; 2015; 16(5):1109-18. PubMed ID: 26356992 [TBL] [Abstract][Full Text] [Related]
38. Factors Leading to and Treatment of Aneurysmal Perforation during Coil Embolization. Analysis of 105 Consecutive Cases. Terada T; Tsuura M; Matsumoto H; Masuo O; Shintani A; Ryujin Y; Itakura T Interv Neuroradiol; 2003 Mar; 9(1):21-9. PubMed ID: 20591299 [TBL] [Abstract][Full Text] [Related]
39. Optimal microcatheter shaping method customized for a patient-specific vessel using a three-dimensional printer. Kim TG J Cerebrovasc Endovasc Neurosurg; 2021 Mar; 23(1):16-22. PubMed ID: 33530677 [TBL] [Abstract][Full Text] [Related]
40. Retrograde stenting through the posterior cerebral artery in coil embolization of the posterior communicating artery aneurysm. Cho YD; Kim KM; Lee WJ; Kang HS; Kim JE; Han MH Neuroradiology; 2013 Jun; 55(6):733-9. PubMed ID: 23479211 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]