These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
128 related articles for article (PubMed ID: 31497098)
61. Monorail snare technique for the recovery of stretched platinum coils: technical case report. Fiorella D; Albuquerque FC; Deshmukh VR; McDougall CG Neurosurgery; 2005 Jul; 57(1 Suppl):E210; discussion E210. PubMed ID: 15987594 [TBL] [Abstract][Full Text] [Related]
62. Marker alignment for Guglielmi detachable coil embolization: practical considerations. Kwon OK; Han MH AJNR Am J Neuroradiol; 2002 Sep; 23(8):1276-83. PubMed ID: 12223365 [TBL] [Abstract][Full Text] [Related]
63. Coil Embolization of Wide-Neck Bifurcation Aneurysms Using a Single-Balloon Microcatheter. Mehta S; Hussain SI; Edgell RC Interv Neurol; 2015 Jul; 3(3-4):135-41. PubMed ID: 26279660 [TBL] [Abstract][Full Text] [Related]
64. Microcatheter looping facilitates access to both the acutely angled parent artery and cerebral aneurysms for effective embolization. Li CH; Ye JY; Su XH; Yang L; Zhang DL; Zhang B; Zhang EW; Han YF; Yang ST; Gao BL Interv Neuroradiol; 2014 Dec; 20(6):669-76. PubMed ID: 25496676 [TBL] [Abstract][Full Text] [Related]
65. Feasibility of insertion of a microcatheter through a Y-stent in coil embolization of cerebral aneurysms and its detailed geometry by micro-computed tomography. Kono K; Terada T Acta Neurochir (Wien); 2014 Jan; 156(1):39-43. PubMed ID: 24190455 [TBL] [Abstract][Full Text] [Related]
66. Shaping the tip of microcatheters for superselective catheterization: steam vs. manual methods. Wattanasatesiri T; Chung JW; Choi TW; Kim HC; Lee M; Hur S Diagn Interv Radiol; 2020 Sep; 26(5):456-463. PubMed ID: 32673203 [TBL] [Abstract][Full Text] [Related]
67. A mechanical coil insertion system for endovascular coil embolization of intracranial aneurysms. Haraguchi K; Miyachi S; Matsubara N; Nagano Y; Yamada H; Marui N; Sano A; Fujimoto H; Izumi T; Yamanouchi T; Asai T; Wakabayashi T Interv Neuroradiol; 2013 Jun; 19(2):159-66. PubMed ID: 23693038 [TBL] [Abstract][Full Text] [Related]
68. The 'one and a half round microcatheterization technique' for stent-assisted coil embolization of intracranial aneurysm: technical case series. Miyachi S; Matsubara N; Izumi T; Asai T; Yamanouchi T; Ota K; Oda K; Wakabayashi T J Neurointerv Surg; 2014 Jun; 6(5):357-62. PubMed ID: 23723289 [TBL] [Abstract][Full Text] [Related]
69. Additional Rescue Stent Placement for Stabilization of a Prolapsed Coil during Stent-assisted Coil Embolization of a Wide-Neck Intracranial Aneurysm. Sourour N; Góngora-Rivera F; Biondi A Interv Neuroradiol; 2006 Sep; 12(3):257-62. PubMed ID: 20569580 [TBL] [Abstract][Full Text] [Related]
70. Microcatheter Looping Technique Facilitates the Embolization of Complex Intracranial Aneurysms with an Acute Angle Branch Incorporated into the Sac. Xiaoxi Z; Jing C; Qinghai H; Jianmin L; Bo H; Dongwei D World Neurosurg; 2017 Apr; 100():56-61. PubMed ID: 28043886 [TBL] [Abstract][Full Text] [Related]
71. Microcatheter entrapment retrieval from Onyx embolization in brain arteriovenous malformations: A technical note. Vu PD; Grigorian AA Interv Neuroradiol; 2015 Oct; 21(5):620-3. PubMed ID: 26232252 [TBL] [Abstract][Full Text] [Related]
72. Endovascular treatment of wide-neck intracranial aneurysms using a microcatheter protective technique: results and outcomes in 75 aneurysms. Lee JY; Seo JH; Cho YD; Kang HS; Han MH AJNR Am J Neuroradiol; 2011 May; 32(5):917-22. PubMed ID: 21393400 [TBL] [Abstract][Full Text] [Related]
73. Improved Endovascular Coiling of Wide-Neck Intracranial Aneurysms in Elderly Patients by Double-Microcatheter Technique. Xu X; Zheng Y; Wang D; Cui J; Shang X Cell Biochem Biophys; 2015 Apr; 71(3):1281-6. PubMed ID: 25476141 [TBL] [Abstract][Full Text] [Related]
74. Folded-Loop Guidewire Remodeling Technique: Catheterizing Markedly Angulated Branches during Intravascular Embolization. Kim DH; Kang UR; Kim YH; Cha JG J Korean Soc Radiol; 2023 Mar; 84(2):418-426. PubMed ID: 37051382 [TBL] [Abstract][Full Text] [Related]
75. A case of anterior communicating artery aneurysm successfully treated after a stent migration during stent assisted endovascular coil embolization. Ohshima T; Belayev A; Goto S; Yamamoto T; Ishikawa K; Kato Y Nagoya J Med Sci; 2017 Feb; 79(2):267-272. PubMed ID: 28626262 [TBL] [Abstract][Full Text] [Related]
76. Bailouts During Neurointervention; Novel Techniques in Tackling Coil Migration and Premature Intravascular Detachment of Microcatheter Tip. Ambrosanio G; Arthimulam G; Leone G; Guarnieri G; Muto M; Muto M World Neurosurg; 2020 Oct; 142():167-170. PubMed ID: 32615295 [TBL] [Abstract][Full Text] [Related]
77. Intraaneurysmal neuroform stent implantation with compartmental dual microcatheter coil embolization: technical case report. Gordhan AD J Neuroimaging; 2010 Jul; 20(3):277-9. PubMed ID: 19732296 [TBL] [Abstract][Full Text] [Related]
78. Modified coil protection for proper coil frame configuration in wide-necked aneurysms. Cho YD; Rhim JK; Park JJ; Jeon JP; Kang HS; Kim JE; Cho WS; Han MH Neuroradiology; 2015 Jul; 57(7):705-11. PubMed ID: 25820139 [TBL] [Abstract][Full Text] [Related]
79. Technique to detect coil migration using mask images of rotational angiography during stent-assisted coil embolization for ultra-wide necked aneurysms: technical note. Shigematsu T; Toyota S; Fujimoto Y; Yamamoto H; Wakayama A; Yoshimine T Neurol Med Chir (Tokyo); 2008 Aug; 48(8):372-5; discussion 375. PubMed ID: 18719330 [TBL] [Abstract][Full Text] [Related]
80. Endovascular coil embolization of middle cerebral artery aneurysms of the proximal (M1) segment. Cho YD; Lee WJ; Kim KM; Kang HS; Kim JE; Han MH Neuroradiology; 2013 Sep; 55(9):1097-102. PubMed ID: 23760351 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]