BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

204 related articles for article (PubMed ID: 31500522)

  • 21. Variation in the shape of pulsed arterial spin labeling kinetic curves across the healthy human brain and its implications for CBF quantification.
    Gallichan D; Jezzard P
    Magn Reson Med; 2009 Mar; 61(3):686-95. PubMed ID: 19132757
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Evaluation of cerebral blood flow using multi-phase pseudo continuous arterial spin labeling at 3-tesla.
    Sugimori H; Fujima N; Suzuki Y; Hamaguchi H; Sakata M; Kudo K
    Magn Reson Imaging; 2015 Dec; 33(10):1338-1344. PubMed ID: 26260545
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Regional and voxel-wise comparisons of blood flow measurements between dynamic susceptibility contrast magnetic resonance imaging (DSC-MRI) and arterial spin labeling (ASL) in brain tumors.
    White CM; Pope WB; Zaw T; Qiao J; Naeini KM; Lai A; Nghiemphu PL; Wang JJ; Cloughesy TF; Ellingson BM
    J Neuroimaging; 2014; 24(1):23-30. PubMed ID: 22672084
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Quantitative measurement of cerebral blood flow in a juvenile porcine model by depth-resolved near-infrared spectroscopy.
    Elliott JT; Diop M; Tichauer KM; Lee TY; St Lawrence K
    J Biomed Opt; 2010; 15(3):037014. PubMed ID: 20615043
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Cerebrovascular reactivity measured with arterial spin labeling and blood oxygen level dependent techniques.
    Zhou Y; Rodgers ZB; Kuo AH
    Magn Reson Imaging; 2015 Jun; 33(5):566-76. PubMed ID: 25708263
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Periprocedural arterial spin labeling and dynamic susceptibility contrast perfusion in detection of cerebral blood flow in patients with acute ischemic syndrome.
    Nael K; Meshksar A; Liebeskind DS; Wang DJ; Ellingson BM; Salamon N; Villablanca JP;
    Stroke; 2013 Mar; 44(3):664-70. PubMed ID: 23391773
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Assesment of perfusion in glial tumors with arterial spin labeling; comparison with dynamic susceptibility contrast method.
    Cebeci H; Aydin O; Ozturk-Isik E; Gumus C; Inecikli F; Bekar A; Kocaeli H; Hakyemez B
    Eur J Radiol; 2014 Oct; 83(10):1914-9. PubMed ID: 25087109
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Validation of Near-Infrared Spectroscopy for Monitoring Cerebral Autoregulation in Comatose Patients.
    Rivera-Lara L; Geocadin R; Zorrilla-Vaca A; Healy R; Radzik BR; Palmisano C; Mirski M; Ziai WC; Hogue C
    Neurocrit Care; 2017 Dec; 27(3):362-369. PubMed ID: 28664392
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Absolute quantification of cerebral blood flow: correlation between dynamic susceptibility contrast MRI and model-free arterial spin labeling.
    Knutsson L; van Westen D; Petersen ET; Markenroth Bloch K; Holtås S; Ståhlberg F; Wirestam R
    Magn Reson Imaging; 2010 Jan; 28(1):1-7. PubMed ID: 19695822
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Noninvasive assessment of cerebral perfusion and oxygenation in acute ischemic stroke by near-infrared spectroscopy.
    Terborg C; Gröschel K; Petrovitch A; Ringer T; Schnaudigel S; Witte OW; Kastrup A
    Eur Neurol; 2009; 62(6):338-43. PubMed ID: 19776588
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Dynamic susceptibility contrast MRI with a prebolus contrast agent administration design for improved absolute quantification of perfusion.
    Knutsson L; Lindgren E; Ahlgren A; van Osch MJ; Bloch KM; Surova Y; Ståhlberg F; van Westen D; Wirestam R
    Magn Reson Med; 2014 Oct; 72(4):996-1006. PubMed ID: 24285621
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Validation study of a pulsed arterial spin labeling technique by comparison to perfusion computed tomography.
    Koziak AM; Winter J; Lee TY; Thompson RT; St Lawrence KS
    Magn Reson Imaging; 2008 May; 26(4):543-53. PubMed ID: 18063336
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Absolute quantification of perfusion by dynamic susceptibility contrast MRI using Bookend and VASO steady-state CBV calibration: a comparison with pseudo-continuous ASL.
    Lindgren E; Wirestam R; Markenroth Bloch K; Ahlgren A; van Osch MJ; van Westen D; Surova Y; Ståhlberg F; Knutsson L
    MAGMA; 2014 Dec; 27(6):487-99. PubMed ID: 24570336
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Quantification of renal perfusion: comparison of arterial spin labeling and dynamic contrast-enhanced MRI.
    Winter JD; St Lawrence KS; Cheng HL
    J Magn Reson Imaging; 2011 Sep; 34(3):608-15. PubMed ID: 21761490
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Correlation and Characteristics of Intravoxel Incoherent Motion and Arterial Spin Labeling Techniques Versus Multiple Parameters Obtained on Dynamic Susceptibility Contrast Perfusion MRI for Brain Tumors.
    Dolgorsuren EA; Harada M; Kanazawa Y; Abe T; Otomo M; Matsumoto Y; Mizobuchi Y; Nakajima K
    J Med Invest; 2019; 66(3.4):308-313. PubMed ID: 31656295
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Comparing accuracy and reproducibility of sequential and Hadamard-encoded multidelay pseudocontinuous arterial spin labeling for measuring cerebral blood flow and arterial transit time in healthy subjects: A simulation and in vivo study.
    Guo J; Holdsworth SJ; Fan AP; Lebel MR; Zun Z; Shankaranarayanan A; Zaharchuk G
    J Magn Reson Imaging; 2018 Apr; 47(4):1119-1132. PubMed ID: 28792653
    [TBL] [Abstract][Full Text] [Related]  

  • 37. [Application of multiple post labeling delay time arterial spin labeling imaging in the quantitative blood flow analysis of brain subregions in healthy adults].
    Li QQ; Chen F; Zhong JG; Shen Y; Dong CS; Yao LZ; Hu JB; Wang S; Niu XC; Dai ZY
    Zhonghua Nei Ke Za Zhi; 2022 Aug; 61(8):908-915. PubMed ID: 35922215
    [No Abstract]   [Full Text] [Related]  

  • 38. T
    Alderliesten T; De Vis JB; Lemmers PMA; van Bel F; Benders MJNL; Hendrikse J; Petersen ET
    Neuroimage; 2016 Oct; 139():65-73. PubMed ID: 27291495
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Absolute quantification of regional renal blood flow in swine by dynamic contrast-enhanced magnetic resonance imaging using a blood pool contrast agent.
    Lüdemann L; Nafz B; Elsner F; Grosse-Siestrup C; Meissler M; Kaufels N; Rehbein H; Persson PB; Michaely HJ; Lengsfeld P; Voth M; Gutberlet M
    Invest Radiol; 2009 Mar; 44(3):125-34. PubMed ID: 19151609
    [TBL] [Abstract][Full Text] [Related]  

  • 40. A linear mixed perfusion model for tissue partial volume correction of perfusion estimates in dynamic susceptibility contrast MRI: Impact on absolute quantification, repeatability, and agreement with pseudo-continuous arterial spin labeling.
    Ahlgren A; Wirestam R; Lind E; Ståhlberg F; Knutsson L
    Magn Reson Med; 2017 Jun; 77(6):2203-2214. PubMed ID: 27321696
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 11.