1. Feasibility of virtual starshot analysis providing submillimeter radiation isocenter accuracy: A long-term multi-institutional analysis.
Akino Y; Fujiwara M; Mizuno H; Shiomi H; Kaneko A; Isohashi F; Seo Y; Suzuki O; Otani K; Tamari K; Ogawa K
J Appl Clin Med Phys; 2019 Oct; 20(10):74-83. PubMed ID: 31502408
[TBL] [Abstract][Full Text] [Related]
2. A novel phantom and procedure providing submillimeter accuracy in daily QA tests of accelerators used for stereotactic radiosurgery*.
Brezovich IA; Popple RA; Duan J; Shen S; Wu X; Benhabib S; Huang M; Cardan RA
J Appl Clin Med Phys; 2016 Jul; 17(4):246-253. PubMed ID: 27455506
[TBL] [Abstract][Full Text] [Related]
3. Efficient quality assurance method with automated data acquisition of a single phantom setup to determine radiation and imaging isocenter congruence.
Kang H; Patel R; Roeske JC
J Appl Clin Med Phys; 2019 Oct; 20(10):127-133. PubMed ID: 31535781
[TBL] [Abstract][Full Text] [Related]
4. A comprehensive geometric quality assurance framework for preclinical microirradiators.
Anvari A; Poirier Y; Sawant A
Med Phys; 2019 Apr; 46(4):1840-1851. PubMed ID: 30656713
[TBL] [Abstract][Full Text] [Related]
5. Alignment of multiradiation isocenters for megavoltage photon beam.
Zhang Y; Ding K; Cowan G; Tryggestad E; Armour E; Wang KK
J Appl Clin Med Phys; 2015 Nov; 16(6):314-324. PubMed ID: 26699586
[TBL] [Abstract][Full Text] [Related]
6. A quality assurance procedure to evaluate cone-beam CT image center congruence with the radiation isocenter of a linear accelerator.
Du W; Yang JN; Chang EL; Luo D; McAleer MF; Shiu A; Martel MK
J Appl Clin Med Phys; 2010 Jul; 11(4):3297. PubMed ID: 21081890
[TBL] [Abstract][Full Text] [Related]
7. Comprehensive radiation and imaging isocenter verification using NIPAM kV-CBCT dosimetry.
Pant K; Umeh C; Oldham M; Floyd S; Giles W; Adamson J
Med Phys; 2020 Mar; 47(3):927-936. PubMed ID: 31899806
[TBL] [Abstract][Full Text] [Related]
8. A daily end-to-end quality assurance workflow for MR-guided online adaptive radiation therapy on MR-Linac.
Chen X; Ahunbay E; Paulson ES; Chen G; Li XA
J Appl Clin Med Phys; 2020 Jan; 21(1):205-212. PubMed ID: 31799753
[TBL] [Abstract][Full Text] [Related]
9. Evaluation of the truebeam machine performance check (MPC): OBI X-ray tube alignment procedure.
Barnes MP; Pomare D; Menk FW; Moraro B; Greer PB
J Appl Clin Med Phys; 2018 Nov; 19(6):68-78. PubMed ID: 30178521
[TBL] [Abstract][Full Text] [Related]
10. [Development of a System for Evaluating the In-room-laser Alignment Including the Horizontality and Verticality Integrated the Light/Radiation Field Coincidence Test and the Winston-Lutz Test].
Shimizu H; Murasawa S; Okudaira K; Aoyama T; Anai S; Nishitani K; Kitagawa T; Sasaki K
Igaku Butsuri; 2021; 41(1):1-9. PubMed ID: 33853977
[TBL] [Abstract][Full Text] [Related]
11. Accuracy of positioning and irradiation targeting for multiple targets in intracranial image-guided radiation therapy: a phantom study.
Tominaga H; Araki F; Shimohigashi Y; Ishihara T; Kawasaki K; Kanetake N; Sakata J; Iwashita Y
Phys Med Biol; 2014 Dec; 59(24):7753-66. PubMed ID: 25419723
[TBL] [Abstract][Full Text] [Related]
12. Simple quality assurance based on filtered back projection for geometrical/irradiation accuracy in single-isocenter multiple-target stereotactic radiotherapy.
Hayashi N; Kurata S; Saito Y; Ogawa S; Yasui K
Radiol Phys Technol; 2022 Dec; 15(4):409-416. PubMed ID: 36261754
[TBL] [Abstract][Full Text] [Related]
13. Assessment of image quality and dose calculation accuracy on kV CBCT, MV CBCT, and MV CT images for urgent palliative radiotherapy treatments.
Held M; Cremers F; Sneed PK; Braunstein S; Fogh SE; Nakamura J; Barani I; Perez-Andujar A; Pouliot J; Morin O
J Appl Clin Med Phys; 2016 Mar; 17(2):279-290. PubMed ID: 27074487
[TBL] [Abstract][Full Text] [Related]
14. An integrated quality assurance phantom for frameless single-isocenter multitarget stereotactic radiosurgery.
Capaldi DPI; Skinner LB; Dubrowski P; Yu AS
Phys Med Biol; 2020 Jun; 65(11):115006. PubMed ID: 32235050
[TBL] [Abstract][Full Text] [Related]
15. Characterization and longitudinal assessment of daily quality assurance for an MR-guided radiotherapy (MRgRT) linac.
Mittauer KE; Dunkerley DAP; Yadav P; Bayouth JE
J Appl Clin Med Phys; 2019 Nov; 20(11):27-36. PubMed ID: 31633882
[TBL] [Abstract][Full Text] [Related]
16. The impact of isocentric shifts on delivery accuracy during the irradiation of small cerebral targets-Quantification and possible corrections.
Wack LJ; Exner F; Wegener S; Sauer OA
J Appl Clin Med Phys; 2020 May; 21(5):56-64. PubMed ID: 32196950
[TBL] [Abstract][Full Text] [Related]
17. Gantry and isocenter displacements of a linear accelerator caused by an add-on micromultileaf collimator.
Riis HL; Zimmermann SJ; Hjelm-Hansen M
Med Phys; 2013 Mar; 40(3):031707. PubMed ID: 23464302
[TBL] [Abstract][Full Text] [Related]
18. Feasibility of a GATE Monte Carlo platform in a clinical pretreatment QA system for VMAT treatment plans using TrueBeam with an HD120 multileaf collimator.
Lee B; Jeong S; Chung K; Yoon M; Park HC; Han Y; Jung SH
J Appl Clin Med Phys; 2019 Oct; 20(10):101-110. PubMed ID: 31544350
[TBL] [Abstract][Full Text] [Related]
19. On the selection of gantry and collimator angles for isocenter localization using Winston-Lutz tests.
Du W; Johnson JL; Jiang W; Kudchadker RJ
J Appl Clin Med Phys; 2016 Jan; 17(1):167-178. PubMed ID: 26894350
[TBL] [Abstract][Full Text] [Related]
20. Clinical commissioning of a new patient positioning system, SyncTraX FX4, for intracranial stereotactic radiotherapy.
Tanabe S; Umetsu O; Sasage T; Utsunomiya S; Kuwabara R; Kuribayashi T; Takatou H; Kawaguchi G; Aoyama H
J Appl Clin Med Phys; 2018 Nov; 19(6):149-158. PubMed ID: 30273444
[TBL] [Abstract][Full Text] [Related]