These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

216 related articles for article (PubMed ID: 31504833)

  • 21. Dominant Circulating Cell-free Mycobacterial Proteins in In-use Machining Fluid and their Antigenicity Potential.
    Chandra H; Ahlers B; Lam YW; Yadav JS
    Curr Protein Pept Sci; 2024; 25(8):613-625. PubMed ID: 38698749
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Presence of a single genotype of the newly described species Mycobacterium immunogenum in industrial metalworking fluids associated with hypersensitivity pneumonitis.
    Wallace RJ; Zhang Y; Wilson RW; Mann L; Rossmoore H
    Appl Environ Microbiol; 2002 Nov; 68(11):5580-4. PubMed ID: 12406752
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Hypersensitivity Pneumonitis Due to Metalworking Fluid Aerosols.
    Burge PS
    Curr Allergy Asthma Rep; 2016 Aug; 16(8):59. PubMed ID: 27473679
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Mycobacterial contamination of metalworking fluids: involvement of a possible new taxon of rapidly growing mycobacteria.
    Moore JS; Christensen M; Wilson RW; Wallace RJ; Zhang Y; Nash DR; Shelton B
    AIHAJ; 2000; 61(2):205-13. PubMed ID: 10782192
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Early immunopathological events in acute model of mycobacterial hypersensitivity pneumonitis in mice.
    Johansson E; Boivin GP; Yadav JS
    J Immunotoxicol; 2017 Dec; 14(1):77-88. PubMed ID: 28094581
    [TBL] [Abstract][Full Text] [Related]  

  • 26. [Mycobacterium immunogenum isolated from a metal worker in Japan].
    Omura H; Kajiki A; Ikegame S; Aono A; Mitarai S; Kitahara Y
    Kekkaku; 2012 Apr; 87(4):341-4. PubMed ID: 22702082
    [TBL] [Abstract][Full Text] [Related]  

  • 27. DNA-based methodologies for rapid detection, quantification, and species- or strain-level identification of respiratory pathogens (Mycobacteria and Pseudomonads) in metalworking fluids.
    Yadav JS; Khan IU; Fakhari F; Soellner MB
    Appl Occup Environ Hyg; 2003 Nov; 18(11):966-75. PubMed ID: 14555451
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Metalworking fluid with mycobacteria and endotoxin induces hypersensitivity pneumonitis in mice.
    Thorne PS; Adamcakova-Dodd A; Kelly KM; O'neill ME; Duchaine C
    Am J Respir Crit Care Med; 2006 Apr; 173(7):759-68. PubMed ID: 16387809
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Asthma, hypersensitivity pneumonitis and other respiratory diseases caused by metalworking fluids.
    Rosenman KD
    Curr Opin Allergy Clin Immunol; 2009 Apr; 9(2):97-102. PubMed ID: 19307882
    [TBL] [Abstract][Full Text] [Related]  

  • 30. A cluster of hypersensitivity pneumonitis associated with exposure to metalworking fluids.
    Tustin AW; Cooney R; Lamson GE; Hodgson MJ
    Am J Ind Med; 2021 Nov; 64(11):915-923. PubMed ID: 34390259
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Machine operator's lung. A hypersensitivity pneumonitis disorder associated with exposure to metalworking fluid aerosols.
    Bernstein DI; Lummus ZL; Santilli G; Siskosky J; Bernstein IL
    Chest; 1995 Sep; 108(3):636-41. PubMed ID: 7656609
    [TBL] [Abstract][Full Text] [Related]  

  • 32. [Hypersensitivity pneumonitis and idiopathic pulmonary fibrosis - case report].
    Mackiewicz B; Siwiec J; Czekajska-Chehab E; Milanowski J
    Pol Merkur Lekarski; 2018 Mar; 44(261):152-156. PubMed ID: 29601568
    [TBL] [Abstract][Full Text] [Related]  

  • 33. External validation of recombinant antigens for serodiagnosis of machine operator's lung.
    Barrera C; Reboux G; Warfolomeow I; Rognon B; Millon L; Roussel S
    Am J Ind Med; 2014 Feb; 57(2):195-201. PubMed ID: 24136133
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Occupational respiratory and skin diseases among workers exposed to metalworking fluids.
    Nett RJ; Stanton M; Grimes GR
    Curr Opin Allergy Clin Immunol; 2021 Apr; 21(2):121-127. PubMed ID: 33394701
    [TBL] [Abstract][Full Text] [Related]  

  • 35. An outbreak of hypersensitivity pneumonitis at a metalworking plant: a longitudinal assessment of intervention effectiveness.
    Bracker A; Storey E; Yang C; Hodgson MJ
    Appl Occup Environ Hyg; 2003 Feb; 18(2):96-108. PubMed ID: 12519684
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Mycobacterium immunogenum causes hypersensitivity pneumonitis-like pathology in mice.
    Gordon T; Nadziejko C; Galdanes K; Lewis D; Donnelly K
    Inhal Toxicol; 2006 May; 18(6):449-56. PubMed ID: 16556584
    [TBL] [Abstract][Full Text] [Related]  

  • 37. [Subacute hypersensitivity pneumonitis after occupational mold exposure].
    Eerikäinen J; Nynäs P; Uitti J
    Duodecim; 2013; 129(9):972-5. PubMed ID: 23786111
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Biopsy-confirmed hypersensitivity pneumonitis in automobile production workers exposed to metalworking fluids--Michigan, 1994-1995.
    Centers for Disease Control and Prevention (CDC)
    MMWR Morb Mortal Wkly Rep; 1996 Jul; 45(28):606-10. PubMed ID: 8676853
    [TBL] [Abstract][Full Text] [Related]  

  • 39. [Occupational hypersensitivity pneumonitis].
    Thaon I; Reboux G; Moulonguet S; Dalphin JC
    Rev Mal Respir; 2006 Dec; 23(6):705-25. PubMed ID: 17202974
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Hypersensitivity pneumonitis caused by metalworking fluid.
    Sastre J; Mur P; García del Potro M; Aguado E
    Allergol Immunopathol (Madr); 2013; 41(5):354-5. PubMed ID: 23265259
    [No Abstract]   [Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 11.