These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

161 related articles for article (PubMed ID: 31511816)

  • 21. Getting PEEK to Stick to Bone: The Development of Porous PEEK for Interbody Fusion Devices.
    Torstrick FB; Safranski DL; Burkus JK; Chappuis JL; Lee CSD; Guldberg RE; Gall K; Smith KE
    Tech Orthop; 2017 Sep; 32(3):158-166. PubMed ID: 29225416
    [TBL] [Abstract][Full Text] [Related]  

  • 22. The effect of titanium particulate on development and maintenance of a posterolateral spinal arthrodesis: an in vivo rabbit model.
    Cunningham BW; Orbegoso CM; Dmitriev AE; Hallab NJ; Sefter JC; McAfee PC
    Spine (Phila Pa 1976); 2002 Sep; 27(18):1971-81. PubMed ID: 12634556
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Early adherence and biofilm formation of Cutibacterium acnes (formerly Propionibacterium acnes) on spinal implant materials.
    Garcia D; Mayfield CK; Leong J; Deckey DG; Zega A; Glasser J; Daniels AH; Eberson C; Green A; Born C
    Spine J; 2020 Jun; 20(6):981-987. PubMed ID: 31972305
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Does impaction of titanium-coated interbody fusion cages into the disc space cause wear debris or delamination?
    Kienle A; Graf N; Wilke HJ
    Spine J; 2016 Feb; 16(2):235-42. PubMed ID: 26409208
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Serum titanium, niobium and aluminium levels two years following instrumented spinal fusion in children: does implant surface area predict serum metal ion levels?
    Cundy TP; Cundy WJ; Antoniou G; Sutherland LM; Freeman BJ; Cundy PJ
    Eur Spine J; 2014 Nov; 23(11):2393-2400. PubMed ID: 24659389
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Revision strategies for salvaging or improving failed cylindrical cages.
    McAfee PC; Cunningham BW; Lee GA; Orbegoso CM; Haggerty CJ; Fedder IL; Griffith SL
    Spine (Phila Pa 1976); 1999 Oct; 24(20):2147-53. PubMed ID: 10543014
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Anterior lumbar fusion with titanium threaded and mesh interbody cages.
    Rauzzino MJ; Shaffrey CI; Nockels RP; Wiggins GC; Rock J; Wagner J
    Neurosurg Focus; 1999 Dec; 7(6):e7. PubMed ID: 16918206
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Hybrid circumferential fixation for degenerative lumbosacral spine disease: posterior lumbar interbody fusion plus universal clamp rod-band instrumentation: a novel technique for lumbosacral fixation.
    Tegos S; Charitidis C; Korovessis PG
    Spine (Phila Pa 1976); 2014 Apr; 39(7):E441-9. PubMed ID: 24430716
    [TBL] [Abstract][Full Text] [Related]  

  • 29. PEEK-Halo effect in interbody fusion.
    Phan K; Hogan JA; Assem Y; Mobbs RJ
    J Clin Neurosci; 2016 Feb; 24():138-40. PubMed ID: 26474500
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Circumferential arthrodesis using PEEK cages at the lumbar spine.
    Rousseau MA; Lazennec JY; Saillant G
    J Spinal Disord Tech; 2007 Jun; 20(4):278-81. PubMed ID: 17538351
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Impaction durability of porous polyether-ether-ketone (PEEK) and titanium-coated PEEK interbody fusion devices.
    Torstrick FB; Klosterhoff BS; Westerlund LE; Foley KT; Gochuico J; Lee CSD; Gall K; Safranski DL
    Spine J; 2018 May; 18(5):857-865. PubMed ID: 29366985
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Evaluation of a polyetheretherketone (PEEK) titanium composite interbody spacer in an ovine lumbar interbody fusion model: biomechanical, microcomputed tomographic, and histologic analyses.
    McGilvray KC; Waldorff EI; Easley J; Seim HB; Zhang N; Linovitz RJ; Ryaby JT; Puttlitz CM
    Spine J; 2017 Dec; 17(12):1907-1916. PubMed ID: 28751242
    [TBL] [Abstract][Full Text] [Related]  

  • 33. The development of whole blood titanium levels after instrumented spinal fusion - is there a correlation between the number of fused segments and titanium levels?
    Ipach I; Schäfer R; Mittag F; Leichtle C; Wolf P; Kluba T
    BMC Musculoskelet Disord; 2012 Aug; 13():159. PubMed ID: 22925526
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Carbon-fiber-reinforced PEEK fixation system in the treatment of spine tumors: a preliminary report.
    Boriani S; Tedesco G; Ming L; Ghermandi R; Amichetti M; Fossati P; Krengli M; Mavilla L; Gasbarrini A
    Eur Spine J; 2018 Apr; 27(4):874-881. PubMed ID: 28815357
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Evaluation of Staphylococcus aureus and Candida albicans biofilms adherence to PEEK and titanium-alloy prosthetic spine devices.
    da Rocha LGDO; Ribeiro VST; de Andrade AP; Gonçalves GA; Kraft L; Cieslinski J; Suss PH; Tuon FF
    Eur J Orthop Surg Traumatol; 2022 Jul; 32(5):981-989. PubMed ID: 34236512
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Serum levels of nickel and chromium after instrumented posterior spinal arthrodesis.
    Kim YJ; Kassab F; Berven SH; Zurakowski D; Hresko MT; Emans JB; Kasser JR
    Spine (Phila Pa 1976); 2005 Apr; 30(8):923-6. PubMed ID: 15834337
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Combination Ti/PEEK ALIF cage for anterior lumbar interbody fusion: Early clinical and radiological results.
    Mobbs RJ; Phan K; Assem Y; Pelletier M; Walsh WR
    J Clin Neurosci; 2016 Dec; 34():94-99. PubMed ID: 27469413
    [TBL] [Abstract][Full Text] [Related]  

  • 38. A 10-year follow-up of transpedicular screw fixation and intervertebral autogenous posterior iliac crest bone graft or intervertebral B-Twin system in failed back surgery syndrome.
    Cincu R; Lorente Fde A; Gomez J; Eiras J; Agrawal A
    Asian J Neurosurg; 2015; 10(2):75-82. PubMed ID: 25972934
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Three cases of metallosis associated with spine instrumentation.
    Ayers R; Miller M; Schowinsky J; Burger E; Patel V; Kleck C
    J Mater Sci Mater Med; 2017 Dec; 29(1):3. PubMed ID: 29196871
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Basic scientific considerations in total disc arthroplasty.
    Cunningham BW
    Spine J; 2004; 4(6 Suppl):219S-230S. PubMed ID: 15541670
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.