These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
229 related articles for article (PubMed ID: 31512024)
1. Comparing the Utility and Surgical Outcomes of Harmonic Focus Ultrasonic Scalpel with Ligasure Small Jaw Bipolar Device in Thyroidectomies: A Prospective Randomized Controlled Trial. Lee SH; Nguyen TK; Ong WS; Haaland B; Tay GC; Tan NC; Tan HK; Ng JCF; Iyer NG Ann Surg Oncol; 2019 Dec; 26(13):4414-4422. PubMed ID: 31512024 [TBL] [Abstract][Full Text] [Related]
2. A Prospective Study Comparing the Efficacy and Surgical Outcomes of Harmonic Focus Scalpel Versus LigaSure Small Jaw in Thyroid and Parathyroid Surgery. Hammad AY; Deniwar A; Al-Qurayshi Z; Mohamed HE; Rizwan A; Kandil E Surg Innov; 2016 Oct; 23(5):486-9. PubMed ID: 27009687 [TBL] [Abstract][Full Text] [Related]
3. Operative time and other outcomes of the electrothermal bipolar vessel sealing system (LigaSure) versus other methods for surgical hemostasis: a meta-analysis. Macario A; Dexter F; Sypal J; Cosgriff N; Heniford BT Surg Innov; 2008 Dec; 15(4):284-91. PubMed ID: 18945705 [TBL] [Abstract][Full Text] [Related]
4. Electrothermal bipolar vessel sealing device vs. ultrasonic coagulating shears in laparoscopic colectomies: a comparative study. Campagnacci R; de Sanctis A; Baldarelli M; Rimini M; Lezoche G; Guerrieri M Surg Endosc; 2007 Sep; 21(9):1526-31. PubMed ID: 17287913 [TBL] [Abstract][Full Text] [Related]
6. Comparison of surgical outcomes between papillary thyroid cancer patients treated with the Harmonic ACE scalpel and LigaSure Precise instrument during conventional thyroidectomy: a single-blind prospective randomized controlled trial. Kwak HY; Chae BJ; Park YG; Kim SH; Chang EY; Kim EJ; Song BJ; Jung SS; Bae JS J Surg Res; 2014 Apr; 187(2):484-9. PubMed ID: 24332551 [TBL] [Abstract][Full Text] [Related]
7. Hepatic resections by means of electrothermal bipolar vessel device (EBVS) LigaSure V: early experience. Campagnacci R; De Sanctis A; Baldarelli M; Di Emiddio M; Organetti L; Nisi M; Lezoche G; Guerrieri M Surg Endosc; 2007 Dec; 21(12):2280-4. PubMed ID: 17514383 [TBL] [Abstract][Full Text] [Related]
8. Comparison of ultrasonic energy, bipolar thermal energy, and vascular clips for the hemostasis of small-, medium-, and large-sized arteries. Harold KL; Pollinger H; Matthews BD; Kercher KW; Sing RF; Heniford BT Surg Endosc; 2003 Aug; 17(8):1228-30. PubMed ID: 12799888 [TBL] [Abstract][Full Text] [Related]
9. Comparison of LigaSure vessel sealing system, harmonic scalpel, and conventional hemostasis in total thyroidectomy. Pons Y; Gauthier J; Ukkola-Pons E; Clément P; Roguet E; Poncet JL; Conessa C Otolaryngol Head Neck Surg; 2009 Oct; 141(4):496-501. PubMed ID: 19786219 [TBL] [Abstract][Full Text] [Related]
10. The use of energy devices for thyroid surgical procedures. Harmonic Focus versus Biclamp 150. Del Rio P; Lazzari G; Rossini M; Nisi P; Perrone G; Bonati E; Sianesi M Ann Ital Chir; 2015; 86():553-9. PubMed ID: 26899723 [TBL] [Abstract][Full Text] [Related]
11. Comparing postoperative complication of LigaSure Small Jaw instrument with clamp and tie method in thyroidectomy patients: a randomized controlled trial [IRCT2014010516077N1]. Ramouz A; Rasihashemi SZ; Safaeiyan A; Hosseini M World J Surg Oncol; 2018 Sep; 16(1):154. PubMed ID: 30236136 [TBL] [Abstract][Full Text] [Related]
12. Use of the harmonic scalpel in thyroidectomy. Parker DJ; Krupa K; Esler R; Vujovic P; Bennett IC ANZ J Surg; 2009 Jun; 79(6):476-80. PubMed ID: 19566873 [TBL] [Abstract][Full Text] [Related]
13. A randomized, prospective, parallel group study comparing the Harmonic Scalpel to electrocautery in thyroidectomy. Cordón C; Fajardo R; Ramírez J; Herrera MF Surgery; 2005 Mar; 137(3):337-41. PubMed ID: 15746789 [TBL] [Abstract][Full Text] [Related]
14. Complications in thyroid surgery. Harmonic Scalpel, Harmonic Focus versus Conventional Hemostasis: A meta-analysis. Revelli L; Damiani G; Bianchi CB; Vanella S; Ricciardi W; Raffaelli M; Lombardi CP Int J Surg; 2016 Apr; 28 Suppl 1():S22-32. PubMed ID: 26768409 [TBL] [Abstract][Full Text] [Related]
15. Comparative study of an electrothermal bipolar vessel sealing system (LigaSure®), a harmonic curved shears (Harmonic Focus™), and traditional technique in total thyroidectomy. Bove A; Bongarzoni G; Palone G; Di Renzo R; Di Nicola M; Corradetti L; Corbellini L Am Surg; 2010 Jul; 76(7):E94-6. PubMed ID: 21683011 [No Abstract] [Full Text] [Related]
16. Novel hemostatic devices in thyroid surgery: electrothermal bipolar vessel sealing system and harmonic scalpel. Manouras A; Markogiannakis HE; Kekis PB; Lagoudianakis EE; Fleming B Expert Rev Med Devices; 2008 Jul; 5(4):447-66. PubMed ID: 18573045 [TBL] [Abstract][Full Text] [Related]
17. Evaluation of a new ultrasonic device in thyroid surgery: comparative randomized study. Miccoli P; Materazzi G; Miccoli M; Frustaci G; Fosso A; Berti P Am J Surg; 2010 Jun; 199(6):736-40. PubMed ID: 20609718 [TBL] [Abstract][Full Text] [Related]
18. Comparison between Focus Harmonic scalpel and other hemostatic techniques in open thyroidectomy: A systematic review and meta-analysis. Cannizzaro MA; Borzì L; Lo Bianco S; Okatyeva V; Cavallaro A; Buffone A Head Neck; 2016 Oct; 38(10):1571-8. PubMed ID: 27224745 [TBL] [Abstract][Full Text] [Related]
19. Post-thyroidectomy complications. The role of the device: bipolar vs ultrasonic device: Collection of data from 1,846 consecutive patients undergoing thyroidectomy. De Palma M; Rosato L; Zingone F; Orlando G; Antonino A; Vitale M; Puzziello A Am J Surg; 2016 Jul; 212(1):116-21. PubMed ID: 26349585 [TBL] [Abstract][Full Text] [Related]
20. Ligasure versus Ultracision in thyroid surgery: a prospective randomized study. Sartori PV; De Fina S; Colombo G; Pugliese F; Romano F; Cesana G; Uggeri F Langenbecks Arch Surg; 2008 Sep; 393(5):655-8. PubMed ID: 18648850 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]