These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

144 related articles for article (PubMed ID: 31516553)

  • 1. Clinical outcomes after carbon-plate osteosynthesis in patients with distal radius fractures.
    Allemann F; Halvachizadeh S; Rauer T; Pape HC
    Patient Saf Surg; 2019; 13():30. PubMed ID: 31516553
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Fixed angle carbon fiber reinforced polymer composite plate for treatment of distal radius fractures : Pilot study on clinical applications].
    Behrendt P; Kruse E; Klüter T; Fitschen-Oestern S; Weuster M; Menzdorf L; Finn J; Varoga D; Seekamp A; Müller M; Lippross S
    Unfallchirurg; 2017 Feb; 120(2):139-146. PubMed ID: 26507986
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Plate Osteosynthesis of Distal Ulna Fractures with Associated Distal Radius Fractures Treated by Open Reduction and Internal Fixation. Short-Term Functional and Radiographic Results].
    Meluzinová P; Kopp L; Dráč P; Edelmann K; Obruba P
    Acta Chir Orthop Traumatol Cech; 2015; 82(5):369-76. PubMed ID: 26516956
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison between Carbon-Peek volar locking plates and titanium volar locking plates in the treatment of distal radius fractures.
    Perugia D; Guzzini M; Mazza D; Iorio C; Civitenga C; Ferretti A
    Injury; 2017 Oct; 48 Suppl 3():S24-S29. PubMed ID: 29025605
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Distal radius plate of CFR-PEEK has minimal effect compared to titanium plates on bone parameters in high-resolution peripheral quantitative computed tomography: a pilot study.
    de Jong JJ; Lataster A; van Rietbergen B; Arts JJ; Geusens PP; van den Bergh JP; Willems PC
    BMC Med Imaging; 2017 Feb; 17(1):18. PubMed ID: 28241752
    [TBL] [Abstract][Full Text] [Related]  

  • 6. PEEK radiolucent plate for distal radius fractures: multicentre clinical results at 12 months follow up.
    Di Maggio B; Sessa P; Mantelli P; Maniscalco P; Rivera F; Calori GM; Bisogno L; Scaravilli G; Caforio M
    Injury; 2017 Oct; 48 Suppl 3():S34-S38. PubMed ID: 29025607
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Palmar plating of distal radius fractures : 3-year follow-up with titanium and PEEK plates give similar outcomes.
    Berger-Groch J; Stodtmeister AC; Petersen JP; Hoffmann M
    Acta Orthop Belg; 2021 Sep; 87(3):521-527. PubMed ID: 34808727
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Stainless steel versus titanium volar multi-axial locking plates for fixation of distal radius fractures: a randomised clinical trial.
    Couzens GB; Peters SE; Cutbush K; Hope B; Taylor F; James CD; Rankin CR; Ross M
    BMC Musculoskelet Disord; 2014 Mar; 15():74. PubMed ID: 24612524
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Biomechanical comparison between stainless steel, titanium and carbon-fiber reinforced polyetheretherketone volar locking plates for distal radius fractures.
    Mugnai R; Tarallo L; Capra F; Catani F
    Orthop Traumatol Surg Res; 2018 Oct; 104(6):877-882. PubMed ID: 29807189
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Comparison of Short-Therm Results of Conservative versus Operative Treatment of Distal Ulna Fractures Associated with Distal Radius Fracture Treated by Plate Osteosynthesis].
    Meluzinová P; Kopp L; Dráč P; Edelmann K; Obruba P
    Acta Chir Orthop Traumatol Cech; 2017; 84(3):182-188. PubMed ID: 28809637
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Conservative and Surgical Treatment for Distal Ulna Fractures Associated with Distal Radius Fractures].
    Vlček M; Pech J; Musil V; Stingl J
    Acta Chir Orthop Traumatol Cech; 2015; 82(6):412-7. PubMed ID: 26787181
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate.
    Arora R; Lutz M; Hennerbichler A; Krappinger D; Espen D; Gabl M
    J Orthop Trauma; 2007 May; 21(5):316-22. PubMed ID: 17485996
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Osteotomy after Distal Radius Fractures - Five-Year Clinical and Radiological Outcomes].
    Cibula Z; Hrubina M; Melišík M; Mudrák I; Nečas L
    Acta Chir Orthop Traumatol Cech; 2018; 85(4):254-260. PubMed ID: 30257755
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Biomechanical Comparison of Volar Fixed-Angle Locking Plates for AO C3 Distal Radius Fractures: Titanium Versus Stainless Steel With Compression.
    Marshall T; Momaya A; Eberhardt A; Chaudhari N; Hunt TR
    J Hand Surg Am; 2015 Oct; 40(10):2032-8. PubMed ID: 26253601
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A biomechanical matched-pair comparison of two different locking plates for tibial diaphyseal comminuted fracture: carbon fiber-reinforced poly-ether-ether-ketone (CF-PEEK) versus titanium plates.
    Zhou K; He X; Tao X; Pan F; Yang H
    J Orthop Surg Res; 2020 Nov; 15(1):558. PubMed ID: 33228695
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Osteosynthesis for periprosthetic supracondylar fracture above a total knee arthroplasty using a locking compression plate].
    Krbec M; Motycka J; Lunácek L; Dousa P
    Acta Chir Orthop Traumatol Cech; 2009 Dec; 76(6):473-8. PubMed ID: 20067694
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Unstable distal radius fractures in the elderly patient--volar fixed-angle plate osteosynthesis prevents secondary loss of reduction.
    Figl M; Weninger P; Jurkowitsch J; Hofbauer M; Schauer J; Leixnering M
    J Trauma; 2010 Apr; 68(4):992-8. PubMed ID: 20065876
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison of functional outcome after volar plate fixation with 2.4-mm titanium versus 3.5-mm stainless-steel plate for extra-articular fracture of distal radius.
    Souer JS; Ring D; Matschke S; Audige L; Maren-Hubert M; Jupiter J
    J Hand Surg Am; 2010 Mar; 35(3):398-405. PubMed ID: 20138716
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Volar PEEK plate for distal radius fracture: analysis of adverse events.
    Tarallo L; Giorgini A; Novi M; Zambianchi F; Porcellini G; Catani F
    Eur J Orthop Surg Traumatol; 2020 Oct; 30(7):1293-1298. PubMed ID: 32435847
    [TBL] [Abstract][Full Text] [Related]  

  • 20. SAFETY AND RELIABILITY OF CARBON-PEEK PLATE FOR THE TREATMENT OF DISTAL RADIUS FRACTURES: A REVIEW OF THE LITERATURE.
    Saracco M; Fulchignoni C; Velluto C; Rocchi L
    Orthop Rev (Pavia); 2021; 13(2):28362. PubMed ID: 35478703
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.