These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

183 related articles for article (PubMed ID: 31516656)

  • 1. Comparison of frictional resistance between passive self-ligating brackets and slide-type low-friction ligature brackets during the alignment and leveling stage.
    Gómez-Gómez SL; Villarraga-Ossa JA; Diosa-Peña JG; Ortiz-Restrepo JF; Castrillón-Marín RA; Ardila CM
    J Clin Exp Dent; 2019 Jul; 11(7):e593-e600. PubMed ID: 31516656
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparison of Frictional Forces Generated by a New Ceramic Bracket with the Conventional Brackets using Unconventional and Conventional Ligation System and the Self-ligating Brackets: An In Vitro Study.
    Pasha A; Vishwakarma S; Narayan A; Vinay K; Shetty SV; Roy PP
    J Int Oral Health; 2015 Sep; 7(9):108-13. PubMed ID: 26435628
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparison of the friction forces delivered by different elastomeric patterns and metal ligature on conventional metal brackets with a NiTi arch wire versus a self-ligating system: An in vitro study.
    Pieroni M; Ferraz Facury AGB; Santamaria-Jr M; Correr AB; Correr-Sobrinho L; Vedovello Filho M; Costa AR; Neves JG
    Int Orthod; 2022 Jun; 20(2):100633. PubMed ID: 35339407
    [TBL] [Abstract][Full Text] [Related]  

  • 4. An in vitro Evaluation of Friction Characteristics of Conventional Stainless Steel and Self-ligating Stainless Steel Brackets with different Dimensions of Archwires in Various Bracket-archwire Combination.
    Sridharan K; Sandbhor S; Rajasekaran UB; Sam G; Ramees MM; Abraham EA
    J Contemp Dent Pract; 2017 Aug; 18(8):660-664. PubMed ID: 28816185
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of frictional resistance between self-ligating and conventional brackets tied with elastomeric and metal ligature in orthodontic archwires.
    Leite VV; Lopes MB; Gonini Júnior A; Almeida MR; Moura SK; Almeida RR
    Dental Press J Orthod; 2014; 19(3):114-9. PubMed ID: 25162575
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Frictional resistance of self-ligating versus conventional brackets in different bracket-archwire-angle combinations.
    Monteiro MR; Silva LE; Elias CN; Vilella Ode V
    J Appl Oral Sci; 2014 Jun; 22(3):228-34. PubMed ID: 25025564
    [TBL] [Abstract][Full Text] [Related]  

  • 7. An in vitro study into the efficacy of complex tooth alignment with conventional and self-ligating brackets.
    Montasser MA; Keilig L; Bourauel C
    Orthod Craniofac Res; 2015 Feb; 18(1):33-42. PubMed ID: 25264808
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Friction in a hybrid system. An in vitro study.
    Rozzi M; Mucedero M; Franchi L; Cozza P
    Oral Implantol (Rome); 2010 Oct; 3(4):2-8. PubMed ID: 23285390
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comparative evaluation of frictional forces in active and passive self-ligating brackets with various archwire alloys.
    Krishnan M; Kalathil S; Abraham KM
    Am J Orthod Dentofacial Orthop; 2009 Nov; 136(5):675-82. PubMed ID: 19892284
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Friction behavior of self-ligating and conventional brackets with different ligature systems.
    Szczupakowski A; Reimann S; Dirk C; Keilig L; Weber A; Jäger A; Bourauel C
    J Orofac Orthop; 2016 Jul; 77(4):287-95. PubMed ID: 27220902
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Evaluation of frictional forces during dental alignment: an experimental model with 3 nonleveled brackets.
    Matarese G; Nucera R; Militi A; Mazza M; Portelli M; Festa F; Cordasco G
    Am J Orthod Dentofacial Orthop; 2008 May; 133(5):708-15. PubMed ID: 18456144
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparison of frictional forces during the closure of extraction spaces in passive self-ligating brackets and conventionally ligated brackets using the finite element method.
    Gómez-Gómez SL; Sánchez-Obando N; Álvarez-Castrillón MA; Montoya-Goez Y; Ardila CM
    J Clin Exp Dent; 2019 May; 11(5):e439-e446. PubMed ID: 31275516
    [TBL] [Abstract][Full Text] [Related]  

  • 13. An in vitro investigation of the influence of self-ligating brackets, low friction ligatures, and archwire on frictional resistance.
    Tecco S; Di Iorio D; Cordasco G; Verrocchi I; Festa F
    Eur J Orthod; 2007 Aug; 29(4):390-7. PubMed ID: 17702800
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Frictional resistance between orthodontic brackets and archwire: an in vitro study.
    Husain N; Kumar A
    J Contemp Dent Pract; 2011 Mar; 12(2):91-9. PubMed ID: 22186750
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison of frictional resistance among conventional, active and passive selfligating brackets with different combinations of arch wires: a finite elements study.
    Gómez SL; Montoya Y; Garcia NL; Virgen AL; Botero JE
    Acta Odontol Latinoam; 2016 Sep; 29(2):130-136. PubMed ID: 27731482
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Friction between various self-ligating brackets and archwire couples during sliding mechanics.
    Stefanos S; Secchi AG; Coby G; Tanna N; Mante FK
    Am J Orthod Dentofacial Orthop; 2010 Oct; 138(4):463-467. PubMed ID: 20889052
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effect of archwire cross-section changes on force levels during complex tooth alignment with conventional and self-ligating brackets.
    Montasser MA; Keilig L; El-Bialy T; Reimann S; Jäger A; Bourauel C
    Am J Orthod Dentofacial Orthop; 2015 Apr; 147(4 Suppl):S101-8. PubMed ID: 25836341
    [TBL] [Abstract][Full Text] [Related]  

  • 18. In vitro evaluation of the frictional forces between brackets and archwire with three passive self-ligating brackets.
    Cordasco G; Farronato G; Festa F; Nucera R; Parazzoli E; Grossi GB
    Eur J Orthod; 2009 Dec; 31(6):643-6. PubMed ID: 19797412
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Friction of conventional and self-ligating brackets using a 10 bracket model.
    Tecco S; Festa F; Caputi S; Traini T; Di Iorio D; D'Attilio M
    Angle Orthod; 2005 Nov; 75(6):1041-5. PubMed ID: 16448253
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Sliding resistance of rectangular vs. beveled archwires in two self-ligating brackets: a finite element study.
    Iriarte AJ; Ortiz S; Cubides-Flechas K; Olaya C; Jaimes-Monroy G
    Acta Odontol Latinoam; 2018 Dec; 31(3):149-155. PubMed ID: 30829370
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.