These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
133 related articles for article (PubMed ID: 31517990)
1. Safety and Efficacy of MRI Scans in Patients With Implanted Microvascular Coupling Devices. Phalke N; Thomas WW; Azzi J; Li RJ; Petrisor D; Wax MK Laryngoscope; 2020 Jun; 130(6):1428-1430. PubMed ID: 31517990 [TBL] [Abstract][Full Text] [Related]
2. Venous anastomoses using microvascular coupler in free flap head and neck reconstruction. Zhang T; Lubek J; Salama A; Caccamese J; Coletti D; Dyalram D; Ord R J Oral Maxillofac Surg; 2012 Apr; 70(4):992-6. PubMed ID: 21741742 [TBL] [Abstract][Full Text] [Related]
3. Salvage arterial anastomosis using a microvascular coupler in head and neck free flap reconstruction. Genther DJ; Day AT; Rana K; Richmon JD Laryngoscope; 2017 Mar; 127(3):642-644. PubMed ID: 27753100 [TBL] [Abstract][Full Text] [Related]
4. Microvascular anastomotic coupler assessment in head and neck reconstruction. Frederick JW; Sweeny L; Carroll WR; Rosenthal EL Otolaryngol Head Neck Surg; 2013 Jul; 149(1):67-70. PubMed ID: 23585150 [TBL] [Abstract][Full Text] [Related]
5. Outcomes of anastomotic venous flow couplers in head and neck free flap reconstruction - five-year experience in a single centre. Bowe CM; Twigg J; Salker AM; Doumas S; Ho MW Br J Oral Maxillofac Surg; 2022 Jul; 60(6):847-851. PubMed ID: 35183371 [TBL] [Abstract][Full Text] [Related]
6. Use of couplers for vascular anastomoses in 601 free flaps for reconstruction of defects of the head and neck: technique and two-year retrospective clinical study. Assoumane A; Wang L; Liu K; Shang ZJ Br J Oral Maxillofac Surg; 2017 Jun; 55(5):461-464. PubMed ID: 28465039 [TBL] [Abstract][Full Text] [Related]
7. Utilization of microvascular couplers in salvage arterial anastomosis in head and neck free flap surgery: Case series and literature review. Li MM; Tamaki A; Seim NB; Kang SY; Ozer E; Agrawal A; Old MO Head Neck; 2020 Aug; 42(8):E1-E7. PubMed ID: 32196817 [TBL] [Abstract][Full Text] [Related]
8. [The application of microvascular anastomotic coupler in vascular anastomosis of free tissue flap for reconstruction of defect after head and neck cancer resection]. Zhang YJ; Wang ZH; Li CH; Chen J Zhonghua Er Bi Yan Hou Tou Jing Wai Ke Za Zhi; 2017 Sep; 52(9):702-706. PubMed ID: 28910897 [No Abstract] [Full Text] [Related]
9. Unique Complications of Venous Anastomotic Couplers: A Systematic Review of the Literature. Wu GJ; Loewenstein SN; Mailey BA; Sasor S; Cook J; Hassanein AH J Reconstr Microsurg; 2020 Jul; 36(6):403-411. PubMed ID: 32106314 [TBL] [Abstract][Full Text] [Related]
11. Analysis of an implantable venous anastomotic flow coupler: experience in head and neck free flap reconstruction. Zhang T; Dyalram-Silverberg D; Bui T; Caccamese JF; Lubek JE Int J Oral Maxillofac Surg; 2012 Jun; 41(6):751-5. PubMed ID: 22480876 [TBL] [Abstract][Full Text] [Related]
12. [Use of coupler for venous anastomoses in cervico-facial reconstruction. Retrospective study on 51 free flaps]. Vernier-Mosca M; Feuvrier D; Obert L; Mauvais O; Loisel F; Pluvy I Ann Chir Plast Esthet; 2020 Jun; 65(3):236-243. PubMed ID: 31353075 [TBL] [Abstract][Full Text] [Related]
13. Preliminary report of the use of a microvascular coupling device for arterial anastomoses in oral and maxillofacial reconstruction. Chen Z; Yu M; Huang S; Zhang S; Li W; Zhang D Br J Oral Maxillofac Surg; 2020 Feb; 58(2):194-198. PubMed ID: 31859103 [TBL] [Abstract][Full Text] [Related]
14. [Application of microvascular coupling device for arterial anastomosis in head and neck reconstruction]. Yu M; Chen ZW; Huang SY; Zhang DS Shanghai Kou Qiang Yi Xue; 2019 Aug; 28(4):435-438. PubMed ID: 31792489 [TBL] [Abstract][Full Text] [Related]
15. Double Thread Suspension: A Novel Technique to Facilitate End-to-Side Venous Anastomosis With a Microvascular Coupling Device in Head and Neck Reconstruction. Zhang S; Xiong T; Li S; Liu X; Yang Y; Zhao Z J Oral Maxillofac Surg; 2021 Sep; 79(9):1954-1962. PubMed ID: 33901452 [TBL] [Abstract][Full Text] [Related]
16. Reliability of venous couplers for microanastomosis of the venae comitantes in free radial forearm flaps for head and neck reconstruction. Patel SA; Pang JH; Natoli N; Gallagher S; Topham N J Reconstr Microsurg; 2013 Sep; 29(7):433-6. PubMed ID: 23588548 [TBL] [Abstract][Full Text] [Related]
17. Influence of coupler size on revision rate and timing of revision after free flap tissue transfer in the head and neck. Kisser U; Adderson-Kisser C; Baumeister P; Reiter M Eur Arch Otorhinolaryngol; 2018 Jan; 275(1):199-206. PubMed ID: 29127507 [TBL] [Abstract][Full Text] [Related]
18. Venous coupler size in autologous breast reconstruction--does it matter? Broer PN; Weichman KE; Tanna N; Wilson S; Ng R; Ahn C; Choi M; Karp NS; Levine JP; Allen RJ Microsurgery; 2013 Oct; 33(7):514-8. PubMed ID: 24038542 [TBL] [Abstract][Full Text] [Related]
19. Comparison of hand-sewn versus modified coupled arterial anastomoses in head and neck reconstruction: a single operator's experience. Guo Z; Cui W; Hu M; Yu B; Han B; Li Y; Tang X; Li C; Li L Int J Oral Maxillofac Surg; 2020 Sep; 49(9):1162-1168. PubMed ID: 32035906 [TBL] [Abstract][Full Text] [Related]
20. Implantable Cook-Swartz Doppler probe versus Synovis Flow Coupler for the post-operative monitoring of free flap breast reconstruction. Um GT; Chang J; Louie O; Colohan SM; Said HK; Neligan PC; Mathes DW J Plast Reconstr Aesthet Surg; 2014 Jul; 67(7):960-6. PubMed ID: 24767693 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]