These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

195 related articles for article (PubMed ID: 31528435)

  • 1. A noninvasive method for the estimation of increased intracranial pressure in patients with severe traumatic brain injury using optic nerve sheath diameter measured on computed tomography head.
    Majeed G; Kashyap S; Menoni R; Miulli D; Sweiss R
    Surg Neurol Int; 2019; 10():97. PubMed ID: 31528435
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Optic nerve sonography in the diagnostic evaluation of adult brain injury.
    Soldatos T; Karakitsos D; Chatzimichail K; Papathanasiou M; Gouliamos A; Karabinis A
    Crit Care; 2008; 12(3):R67. PubMed ID: 18477382
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Ultrasonographic optic nerve sheath diameter correlation with ICP and accuracy as a tool for noninvasive surrogate ICP measurement in patients with decompressive craniotomy.
    Wang J; Li K; Li H; Ji C; Wu Z; Chen H; Chen B
    J Neurosurg; 2020 Aug; 133(2):514-520. PubMed ID: 31323632
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Optic nerve sheath diameter on computed tomography is correlated with simultaneously measured intracranial pressure in patients with severe traumatic brain injury.
    Sekhon MS; Griesdale DE; Robba C; McGlashan N; Needham E; Walland K; Shook AC; Smielewski P; Czosnyka M; Gupta AK; Menon DK
    Intensive Care Med; 2014 Sep; 40(9):1267-74. PubMed ID: 25034476
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Role of serial ultrasonic optic nerve sheath diameter monitoring in head injury.
    Thotakura AK; Marabathina NR; Danaboyina AR; Mareddy RR
    Neurochirurgie; 2017 Dec; 63(6):444-448. PubMed ID: 29122307
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Correlation of intracranial pressure and diameter of the sheath of the optic nerve by computed tomography in severe traumatic brain injury].
    Turkin AM; Oshorov AV; Pogosbekyan EL; Smirnov AS; Dmitrieva AS
    Zh Vopr Neirokhir Im N N Burdenko; 2017; 81(6):81-88. PubMed ID: 29393290
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Optic Nerve Sheath Measurements by Computed Tomography to Predict Intracranial Pressure and Guide Surgery in Patients with Traumatic Brain Injury.
    Liu M; Yang ZK; Yan YF; Shen X; Yao HB; Fei L; Wang ES
    World Neurosurg; 2020 Feb; 134():e317-e324. PubMed ID: 31629929
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Ultrasonographic measured optic nerve sheath diameter as an accurate and quick monitor for changes in intracranial pressure.
    Maissan IM; Dirven PJ; Haitsma IK; Hoeks SE; Gommers D; Stolker RJ
    J Neurosurg; 2015 Sep; 123(3):743-7. PubMed ID: 25955869
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Ratio of Optic Nerve Sheath Diameter to Eyeball Transverse Diameter by Ultrasound Can Predict Intracranial Hypertension in Traumatic Brain Injury Patients: A Prospective Study.
    Du J; Deng Y; Li H; Qiao S; Yu M; Xu Q; Wang C
    Neurocrit Care; 2020 Apr; 32(2):478-485. PubMed ID: 31218637
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Optic Nerve Sheath Diameter Correlation with Elevated Intracranial Pressure Determined via Ultrasound.
    Munawar K; Khan MT; Hussain SW; Qadeer A; Shad ZS; Bano S; Abdullah A
    Cureus; 2019 Feb; 11(2):e4145. PubMed ID: 31058028
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Bedside Ultrasonographic Assessment of Optic Nerve Sheath Diameter As a Means of Detecting Raised Intracranial Pressure in Neuro-Trauma Patients: A Cross-Sectional Study.
    Kaur A; Gautam PL; Sharma S; Singh VP; Sharma S
    Ann Indian Acad Neurol; 2021; 24(1):63-68. PubMed ID: 33911381
    [TBL] [Abstract][Full Text] [Related]  

  • 12. New Optic Nerve Sonography Quality Criteria in the Diagnostic Evaluation of Traumatic Brain Injury.
    Soliman I; Johnson GGRJ; Gillman LM; Zeiler FA; Faqihi F; Aletreby WT; Balhamar A; Mahmood NN; Ahmad Mumtaz S; Alharthy A; Lazaridis C; Karakitsos D
    Crit Care Res Pract; 2018; 2018():3589762. PubMed ID: 29854448
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The concordance of optic nerve sheath diameter measurements with the clinical course in children with traumatic head injury.
    Kavak RP; Özdemir M; Kavak N; Ertan N; Külah B
    Ulus Travma Acil Cerrahi Derg; 2020 Sep; 26(5):728-734. PubMed ID: 32946080
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Sonographic optic nerve sheath diameter as an estimate of intracranial pressure in adult trauma.
    Strumwasser A; Kwan RO; Yeung L; Miraflor E; Ereso A; Castro-Moure F; Patel A; Sadjadi J; Victorino GP
    J Surg Res; 2011 Oct; 170(2):265-71. PubMed ID: 21550065
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Ultrasonography of the optic nerve sheath may be useful for detecting raised intracranial pressure after severe brain injury.
    Geeraerts T; Launey Y; Martin L; Pottecher J; Vigué B; Duranteau J; Benhamou D
    Intensive Care Med; 2007 Oct; 33(10):1704-11. PubMed ID: 17668184
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Noninvasive intracranial pressure assessment by optic nerve sheath diameter: Automated measurements as an alternative to clinician-performed measurements.
    Netteland DF; Aarhus M; Smistad E; Sandset EC; Padayachy L; Helseth E; Brekken R
    Front Neurol; 2023; 14():1064492. PubMed ID: 36816558
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Relationship of Optic Nerve Sheath Diameter and Intracranial Hypertension in Patients with Traumatic Brain Injury.
    Al-Hassani A; Strandvik G; Abayazeed S; Ahmed K; El-Menyar A; Mahmood I; Arumugam SK; Asim M; Nabir S; Ahmed N; Ahmed Z; Al-Thani H
    J Emerg Trauma Shock; 2020; 13(3):183-189. PubMed ID: 33304067
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Intracranial Pressure Assessment in Traumatic Head Injury with Hemorrhage Via Optic Nerve Sheath Diameter.
    Vaiman M; Sigal T; Kimiagar I; Bekerman I
    J Neurotrauma; 2016 Dec; 33(23):2147-2153. PubMed ID: 27048793
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Optic nerve sheath diameter ultrasonography at admission as a predictor of intracranial hypertension in traumatic brain injured patients: a prospective observational study.
    Robba C; Donnelly J; Cardim D; Tajsic T; Cabeleira M; Citerio G; Pelosi P; Smielewski P; Hutchinson P; Menon DK; Czosnyka M
    J Neurosurg; 2020 Apr; 132(4):1279-1285. PubMed ID: 30849751
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Noninvasive assessment of the intracranial pressure in non-traumatic intracranial hemorrhage.
    Vaiman M; Sigal T; Kimiagar I; Bekerman I
    J Clin Neurosci; 2016 Dec; 34():177-181. PubMed ID: 27612672
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.