These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
181 related articles for article (PubMed ID: 31537173)
21. A novel method to determine linac mechanical isocenter position and size and examples of specific QA applications. Chojnowski JM; Sykes JR; Thwaites DI J Appl Clin Med Phys; 2021 Jul; 22(7):44-55. PubMed ID: 34056850 [TBL] [Abstract][Full Text] [Related]
22. Two-dimensional EPID dosimetry for an MR-linac: Proof of concept. Torres-Xirau I; Olaciregui-Ruiz I; van der Heide UA; Mans A Med Phys; 2019 Sep; 46(9):4193-4203. PubMed ID: 31199521 [TBL] [Abstract][Full Text] [Related]
23. Alignment of multiradiation isocenters for megavoltage photon beam. Zhang Y; Ding K; Cowan G; Tryggestad E; Armour E; Wang KK J Appl Clin Med Phys; 2015 Nov; 16(6):314-324. PubMed ID: 26699586 [TBL] [Abstract][Full Text] [Related]
24. A novel verification method using a plastic scintillator imagining system for assessment of gantry sag in radiotherapy. Tsuneda M; Nishio T; Saito A; Tanaka S; Suzuki T; Kawahara D; Matsushita K; Nishio A; Ozawa S; Karasawa K; Nagata Y Med Phys; 2018 Jun; 45(6):2411-2424. PubMed ID: 29663431 [TBL] [Abstract][Full Text] [Related]
26. An improved method for evaluating LINAC isocenter. Zacharopoulos NG; Fenyes DA Med Phys; 2023 May; 50(5):2672-2682. PubMed ID: 36896920 [TBL] [Abstract][Full Text] [Related]
27. First patients treated with a 1.5 T MRI-Linac: clinical proof of concept of a high-precision, high-field MRI guided radiotherapy treatment. Raaymakers BW; Jürgenliemk-Schulz IM; Bol GH; Glitzner M; Kotte ANTJ; van Asselen B; de Boer JCJ; Bluemink JJ; Hackett SL; Moerland MA; Woodings SJ; Wolthaus JWH; van Zijp HM; Philippens MEP; Tijssen R; Kok JGM; de Groot-van Breugel EN; Kiekebosch I; Meijers LTC; Nomden CN; Sikkes GG; Doornaert PAH; Eppinga WSC; Kasperts N; Kerkmeijer LGW; Tersteeg JHA; Brown KJ; Pais B; Woodhead P; Lagendijk JJW Phys Med Biol; 2017 Nov; 62(23):L41-L50. PubMed ID: 29135471 [TBL] [Abstract][Full Text] [Related]
28. An EPID-based method to determine mechanical deformations in a linear accelerator. Gourdeau D; Gingras L; Beaulieu F; Leclerc G; Archambault L Med Phys; 2018 Nov; 45(11):5054-5065. PubMed ID: 30242848 [TBL] [Abstract][Full Text] [Related]
29. SU-E-J-49: Reliability Study of ExacTrac- System Image Isocenter Using an On-Demand QA Procedure. Wang X; Zhao Z; Du W; Li X; Yang J Med Phys; 2012 Jun; 39(6Part6):3663. PubMed ID: 28517561 [TBL] [Abstract][Full Text] [Related]
30. Scintillation imaging as a high-resolution, remote, versatile 2D detection system for MR-linac quality assurance. Alexander DA; Zhang R; Brůža P; Pogue BW; Gladstone DJ Med Phys; 2020 Sep; 47(9):3861-3869. PubMed ID: 32583484 [TBL] [Abstract][Full Text] [Related]
31. Commissioning of a 1.5T Elekta Unity MR-linac: A single institution experience. Snyder JE; St-Aubin J; Yaddanapudi S; Boczkowski A; Dunkerley DAP; Graves SA; Hyer DE J Appl Clin Med Phys; 2020 Jul; 21(7):160-172. PubMed ID: 32432405 [TBL] [Abstract][Full Text] [Related]
32. Evaluation of cine imaging during multileaf collimator and gantry motion for real-time magnetic resonance guided radiation therapy. Kielbasa JE; Meeks SL; Kelly P; Willoughby TR; Zeidan O; Shah AP J Appl Clin Med Phys; 2020 Dec; 21(12):178-187. PubMed ID: 33226709 [TBL] [Abstract][Full Text] [Related]
33. Feasibility study of performing IGRT system daily QA using a commercial QA device. Peng JL; Kahler D; Li JG; Amdur RJ; Vanek KN; Liu C J Appl Clin Med Phys; 2011 Jun; 12(3):3535. PubMed ID: 21844867 [TBL] [Abstract][Full Text] [Related]
34. Assessment of image quality and scatter and leakage radiation of an integrated MR-LINAC system. Wang J; Yung J; Kadbi M; Hwang K; Ding Y; Ibbott GS Med Phys; 2018 Mar; 45(3):1204-1209. PubMed ID: 29363770 [TBL] [Abstract][Full Text] [Related]
35. Visual Isocenter Position Enhanced Review (VIPER): a Cherenkov imaging-based solution for MR-linac daily QA. Alexander DA; Bruza P; Rassias AG; Andreozzi JM; Pogue BW; Zhang R; Gladstone DJ Med Phys; 2021 Jun; 48(6):2750-2759. PubMed ID: 33887796 [TBL] [Abstract][Full Text] [Related]
36. [Development of an automated method for analysis of Winston-Lutz test results using digital radiography and photostimulable storage phosphor]. Nagafuchi K; Kawata H; Nashiki K; Ohkura S; Hayashida K; Kawahara T; Ohishi A; Mizoguchi A; Saida Y Nihon Hoshasen Gijutsu Gakkai Zasshi; 2013 Nov; 69(11):1266-73. PubMed ID: 24256650 [TBL] [Abstract][Full Text] [Related]
37. Design of a novel 5-camera surface guidance system with multiple imaging isocenters. Ates O; Zhao L; Sobczak D; Pirlepesov F; Hua CH; Waghorn B; Merchant TE J Appl Clin Med Phys; 2022 Oct; 23(10):e13750. PubMed ID: 35946854 [TBL] [Abstract][Full Text] [Related]
38. Acceptance procedure for the linear accelerator component of the 1.5 T MRI-linac. Woodings SJ; de Vries JHW; Kok JMG; Hackett SL; van Asselen B; Bluemink JJ; van Zijp HM; van Soest TL; Roberts DA; Lagendijk JJW; Raaymakers BW; Wolthaus JWH J Appl Clin Med Phys; 2021 Aug; 22(8):45-59. PubMed ID: 34275176 [TBL] [Abstract][Full Text] [Related]
39. Electron streams in air during magnetic-resonance image-guided radiation therapy. An HJ; Kim JI; Park JM PLoS One; 2019; 14(5):e0216965. PubMed ID: 31091270 [TBL] [Abstract][Full Text] [Related]
40. Improved accuracy for noncoplanar radiotherapy: an EPID-based method for submillimeter alignment of linear accelerator table rotation with MV isocenter. Nyflot MJ; Cao N; Meyer J; Ford EC J Appl Clin Med Phys; 2014 Mar; 15(2):4682. PubMed ID: 24710457 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]