These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

289 related articles for article (PubMed ID: 31541398)

  • 1. Perilesional emphysema as a predictor of risk of complications from computed tomography-guided transthoracic lung biopsy.
    Lee DS; Bak SH; Jeon YH; Kwon SO; Kim WJ
    Jpn J Radiol; 2019 Dec; 37(12):808-816. PubMed ID: 31541398
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Safety and efficacy of tract embolization using gelatin sponge particles in reducing pneumothorax after CT-guided percutaneous lung biopsy in patients with emphysema.
    Yang X; Cheng HT; Huang Y; Guo Y; Yuan H; Chen YQ; Li HL
    BMC Pulm Med; 2024 Jul; 24(1):329. PubMed ID: 38982416
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Computed tomography-navigated transthoracic core biopsy of pulmonary lesions: which factors affect diagnostic yield and complication rates?
    Heyer CM; Reichelt S; Peters SA; Walther JW; Müller KM; Nicolas V
    Acad Radiol; 2008 Aug; 15(8):1017-26. PubMed ID: 18620122
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Efficacy of the tract embolization technique with gelatin sponge slurry to reduce pneumothorax and chest tube placement after percutaneous CT-guided lung biopsy.
    Renier H; Gérard L; Lamborelle P; Cousin F
    Cardiovasc Intervent Radiol; 2020 Apr; 43(4):597-603. PubMed ID: 31792589
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Pneumothorax after CT-guided transthoracic lung biopsy: A comparison between immediate and delayed occurrence.
    Bae K; Ha JY; Jeon KN
    PLoS One; 2020; 15(8):e0238107. PubMed ID: 32834016
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Pneumothorax with prolonged chest tube requirement after CT-guided percutaneous lung biopsy: incidence and risk factors.
    Moreland A; Novogrodsky E; Brody L; Durack J; Erinjeri J; Getrajdman G; Solomon S; Yarmohammadi H; Maybody M
    Eur Radiol; 2016 Oct; 26(10):3483-91. PubMed ID: 26787605
    [TBL] [Abstract][Full Text] [Related]  

  • 7. CT-guided Lung Biopsy: Effect of Biopsy-side Down Position on Pneumothorax and Chest Tube Placement.
    Drumm O; Joyce EA; de Blacam C; Gleeson T; Kavanagh J; McCarthy E; McDermott R; Beddy P
    Radiology; 2019 Jul; 292(1):190-196. PubMed ID: 31084480
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Frequency and Severity of Pulmonary Hemorrhage in Patients Undergoing Percutaneous CT-guided Transthoracic Lung Biopsy: Single-Institution Experience of 1175 Cases.
    Tai R; Dunne RM; Trotman-Dickenson B; Jacobson FL; Madan R; Kumamaru KK; Hunsaker AR
    Radiology; 2016 Apr; 279(1):287-96. PubMed ID: 26479161
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Impact of quantitative pulmonary emphysema score on the rate of pneumothorax and chest tube insertion in CT-guided lung biopsies.
    Theilig D; Petschelt D; Mayerhofer A; Hamm B; Gebauer B; Geisel D
    Sci Rep; 2020 Jul; 10(1):10978. PubMed ID: 32620852
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Complications of CT-guided lung biopsy with a non-coaxial semi-automated 18 gauge biopsy system: Frequency, severity and risk factors.
    Elshafee AS; Karch A; Ringe KI; Shin HO; Raatschen HJ; Soliman NY; Wacker F; Vogel-Claussen J
    PLoS One; 2019; 14(3):e0213990. PubMed ID: 30883575
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Pneumothorax and pulmonary hemorrhage after CT-guided lung biopsy: incidence, clinical significance and correlation.
    Sabatino V; Russo U; D'Amuri F; Bevilacqua A; Pagnini F; Milanese G; Gentili F; Nizzoli R; Tiseo M; Pedrazzi G; De Filippo M
    Radiol Med; 2021 Jan; 126(1):170-177. PubMed ID: 32377914
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A Retrospective Analysis of the Effectiveness of Extrapleural Autologous Blood Patch Injection on Pneumothorax and Intervention Need in CT-guided Lung Biopsy.
    Türk Y; Devecioğlu İ
    Cardiovasc Intervent Radiol; 2021 Aug; 44(8):1223-1230. PubMed ID: 34021378
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Risk factors for pneumothorax and pulmonary hemorrhage following computed tomography-guided transthoracic core-needle biopsy of subpleural lung lesions.
    Chiu JH; Chang YY; Weng CY; Lee YC; Yeh YC; Chen CK
    J Chin Med Assoc; 2022 Apr; 85(4):500-506. PubMed ID: 35383704
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Usual Interstitial Pneumonia: Associations With Complications After Percutaneous Transthoracic Needle Lung Biopsy.
    Park J; Lee JH; Hong W; Hwang EJ; Yoon SH; Goo JM; Park CM
    AJR Am J Roentgenol; 2024 Feb; 222(2):e2329938. PubMed ID: 37910039
    [No Abstract]   [Full Text] [Related]  

  • 15. Pneumothorax Incidence with Normal Saline Instillation for Sealing the Needle Track After Computed Tomography-Guided Percutaneous Lung Biopsy.
    Bourgeais G; Frampas E; Liberge R; Nicolas A; Defrance C; Blanc FX; Coudol S; Morla O
    Cardiovasc Intervent Radiol; 2024 May; 47(5):604-612. PubMed ID: 38263525
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Predictors of pneumothorax after CT-guided transthoracic needle lung biopsy: the role of quantitative CT.
    Chami HA; Faraj W; Yehia ZA; Badour SA; Sawan P; Rebeiz K; Safa R; Saade C; Ghandour B; Shamseddine A; Mukherji D; Haydar AA
    Clin Radiol; 2015 Dec; 70(12):1382-7. PubMed ID: 26392317
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Frequency and Risk Factors for Air Embolism in Computed Tomography Fluoroscopy-Guided Biopsy of Lung Tumor With the Use of Noncoaxial Automatic Needle.
    Maehara Y; Miura H; Hirota T; Asai S; Okamoto T; Ohara Y; Yamada K
    J Comput Assist Tomogr; 2023 Jan-Feb 01; 47(1):71-77. PubMed ID: 36194845
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Abnormal Pulmonary Function Testing as an Independent Risk Factor for Procedural Complications During Transthoracic Needle Biopsies.
    Rothman A; Lim S; Hasegawa D; Steiger D; Patel R; Lee YI
    J Bronchology Interv Pulmonol; 2022 Jul; 29(3):213-219. PubMed ID: 34693922
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Pneumothoraces and chest tube placement after CT-guided transthoracic lung biopsy using a coaxial technique: incidence and risk factors.
    Laurent F; Michel P; Latrabe V; Tunon de Lara M; Marthan R
    AJR Am J Roentgenol; 1999 Apr; 172(4):1049-53. PubMed ID: 10587145
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The Effect of Needle Gauge on the Risk of Pneumothorax and Chest Tube Placement After Percutaneous Computed Tomographic (CT)-Guided Lung Biopsy.
    Kuban JD; Tam AL; Huang SY; Ensor JE; Philip AS; Chen GJ; Ahrar J; Murthy R; Avritscher R; Madoff DC; Mahvash A; Ahrar K; Wallace MJ; Nachiappan AC; Gupta S
    Cardiovasc Intervent Radiol; 2015 Dec; 38(6):1595-602. PubMed ID: 25920917
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 15.