These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
5. Morphologic changes in the anterior chamber in patients with cortical or nuclear age-related cataract. Chen Y; Bao YZ; Pei XT J Cataract Refract Surg; 2011 Jan; 37(1):77-82. PubMed ID: 21183102 [TBL] [Abstract][Full Text] [Related]
6. [Dislocation of the crystalline lens into the anterior chamber following couching: Case report]. Jait A; Jait M; Lezrek O; Amazouzi A; El Haouzi S; Charkaoui W J Fr Ophtalmol; 2017 Nov; 40(9):e327-e328. PubMed ID: 29032827 [No Abstract] [Full Text] [Related]
7. [Spontaneous bilateral dislocation of the crystalline lens in the case of a patient with homocystinuria, with anterior chamber OCT showing endothelial damage]. Gascon P; Marc C; Guigou S J Fr Ophtalmol; 2015 Oct; 38(8):e173-5. PubMed ID: 26138529 [No Abstract] [Full Text] [Related]
8. [Dislocation of the crystalline lens into the anterior chamber]. Bettich Z; Lezrek O; Cherkaoui LO J Fr Ophtalmol; 2018 Dec; 41(10):1003-1004. PubMed ID: 30449644 [No Abstract] [Full Text] [Related]
9. Spontaneous dislocation of a transparent lens to the anterior chamber--a case report. Jovanović M; Stefanović I Srp Arh Celok Lek; 2010; 138(7-8):486-8. PubMed ID: 20842896 [TBL] [Abstract][Full Text] [Related]
10. Sudden corneal edema due to retained lens nuclear fragment presenting 8.5 years after cataract surgery. Pandit RT; Coburn AG J Cataract Refract Surg; 2011 Jun; 37(6):1165-7. PubMed ID: 21596261 [TBL] [Abstract][Full Text] [Related]
11. Argon laser iridotomy as a possible cause of anterior dislocation of a crystalline lens. Seong M; Kim MJ; Tchah H J Cataract Refract Surg; 2009 Jan; 35(1):190-2. PubMed ID: 19101444 [TBL] [Abstract][Full Text] [Related]
12. Bilateral spontaneous crystalline lens dislocation to the anterior chamber: a case report. Jovanović M Srp Arh Celok Lek; 2013; 141(11-12):800-2. PubMed ID: 24502101 [TBL] [Abstract][Full Text] [Related]
14. Retained lens nuclear fragment presenting years after phacoemulsification. Nair M; Pandit RT J Cataract Refract Surg; 2014 Oct; 40(10):1752. PubMed ID: 25263054 [No Abstract] [Full Text] [Related]
15. Complications of retained nuclear fragments in the anterior chamber after phacoemulsification with posterior chamber lens implant. Bohigian GM; Wexler SA Am J Ophthalmol; 1997 Apr; 123(4):546-7. PubMed ID: 9124252 [TBL] [Abstract][Full Text] [Related]
16. YAG laser demonstration of the anatomy of the lens nucleus. Drews RC Ophthalmic Surg; 1992 Dec; 23(12):822-4. PubMed ID: 1494437 [TBL] [Abstract][Full Text] [Related]
17. [Lens dislocation into the anterior chamber]. El Bahloul M; Chraïbi F; Abdellaoui M; Benatiya I; Tahri H J Fr Ophtalmol; 2017 Dec; 40(10):901. PubMed ID: 29169642 [No Abstract] [Full Text] [Related]