454 related articles for article (PubMed ID: 31556831)
1. Time-based pulmonary features from electrical impedance tomography demonstrate ventilation heterogeneity in chronic obstructive pulmonary disease.
Milne S; Huvanandana J; Nguyen C; Duncan JM; Chapman DG; Tonga KO; Zimmermann SC; Slattery A; King GG; Thamrin C
J Appl Physiol (1985); 2019 Nov; 127(5):1441-1452. PubMed ID: 31556831
[TBL] [Abstract][Full Text] [Related]
2. Oscillometry and pulmonary MRI measurements of ventilation heterogeneity in obstructive lung disease: relationship to quality of life and disease control.
Young HM; Guo F; Eddy RL; Maksym G; Parraga G
J Appl Physiol (1985); 2018 Jul; 125(1):73-85. PubMed ID: 29543132
[TBL] [Abstract][Full Text] [Related]
3. Spatial and temporal heterogeneity of regional lung ventilation determined by electrical impedance tomography during pulmonary function testing.
Vogt B; Pulletz S; Elke G; Zhao Z; Zabel P; Weiler N; Frerichs I
J Appl Physiol (1985); 2012 Oct; 113(7):1154-61. PubMed ID: 22898553
[TBL] [Abstract][Full Text] [Related]
4. Regional lung response to bronchodilator reversibility testing determined by electrical impedance tomography in chronic obstructive pulmonary disease.
Vogt B; Zhao Z; Zabel P; Weiler N; Frerichs I
Am J Physiol Lung Cell Mol Physiol; 2016 Jul; 311(1):L8-L19. PubMed ID: 27190067
[TBL] [Abstract][Full Text] [Related]
5. Assessing regional lung mechanics by combining electrical impedance tomography and forced oscillation technique.
Ngo C; Spagnesi S; Munoz C; Lehmann S; Vollmer T; Misgeld B; Leonhardt S
Biomed Tech (Berl); 2018 Nov; 63(6):673-681. PubMed ID: 28850542
[TBL] [Abstract][Full Text] [Related]
6. Regional lung function measures determined by electrical impedance tomography during repetitive ventilation manoeuvres in patients with COPD.
Lasarow L; Vogt B; Zhao Z; Balke L; Weiler N; Frerichs I
Physiol Meas; 2021 Feb; 42(1):015008. PubMed ID: 33434902
[TBL] [Abstract][Full Text] [Related]
7. [Measuring breathing pattern in patients with chronic obstructive pulmonary disease by electrical impedance tomography].
Balleza M; Calaf N; Feixas T; González M; Antón D; Riu PJ; Casan P
Arch Bronconeumol; 2009 Jul; 45(7):320-4. PubMed ID: 19497652
[TBL] [Abstract][Full Text] [Related]
8. Regional expiratory time constants in severe respiratory failure estimated by electrical impedance tomography: a feasibility study.
Karagiannidis C; Waldmann AD; Róka PL; Schreiber T; Strassmann S; Windisch W; Böhm SH
Crit Care; 2018 Sep; 22(1):221. PubMed ID: 30236123
[TBL] [Abstract][Full Text] [Related]
9. Association between respiratory impedance measured by forced oscillation technique and exacerbations in patients with COPD.
Yamagami H; Tanaka A; Kishino Y; Mikuni H; Kawahara T; Ohta S; Yamamoto M; Suzuki S; Ohnishi T; Sagara H
Int J Chron Obstruct Pulmon Dis; 2018; 13():79-89. PubMed ID: 29317813
[TBL] [Abstract][Full Text] [Related]
10. Accuracy of forced oscillation technique to assess lung function in geriatric COPD population.
Tse HN; Tseng CZ; Wong KY; Yee KS; Ng LY
Int J Chron Obstruct Pulmon Dis; 2016; 11():1105-18. PubMed ID: 27307726
[TBL] [Abstract][Full Text] [Related]
11. Pulmonary vascular responses to hypoxia and hyperoxia in healthy volunteers and COPD patients measured by electrical impedance tomography.
Smit HJ; Vonk-Noordegraaf A; Marcus JT; van der Weijden S; Postmus PE; de Vries PM; Boonstra A
Chest; 2003 Jun; 123(6):1803-9. PubMed ID: 12796153
[TBL] [Abstract][Full Text] [Related]
12. Regional lung function determined by electrical impedance tomography during bronchodilator reversibility testing in patients with asthma.
Frerichs I; Zhao Z; Becher T; Zabel P; Weiler N; Vogt B
Physiol Meas; 2016 Jun; 37(6):698-712. PubMed ID: 27203725
[TBL] [Abstract][Full Text] [Related]
13. Novel Respiratory Impedance-Based Phenotypes Reflect Different Pathophysiologies in Chronic Obstructive Pulmonary Disease Patients.
Matsuo Y; Ogawa E; Seto-Yukimura R; Ryujin Y; Kinose D; Yamaguchi M; Osawa M; Nagao T; Kurosawa H; Nakano Y
Int J Chron Obstruct Pulmon Dis; 2019; 14():2971-2977. PubMed ID: 31908445
[TBL] [Abstract][Full Text] [Related]
14. Effects of indacaterol versus tiotropium on respiratory mechanics assessed by the forced oscillation technique in patients with chronic obstructive pulmonary disease.
Inui N; Matsushima S; Kato S; Yasui H; Kono M; Fujisawa T; Enomoto N; Nakamura Y; Toyoshima M; Suda T
Int J Chron Obstruct Pulmon Dis; 2015; 10():1139-46. PubMed ID: 26124653
[TBL] [Abstract][Full Text] [Related]
15. Relationships Between Forced Oscillatory Impedance and 6-minute Walk Distance After Pulmonary Rehabilitation in COPD.
Zimmermann SC; Thamrin C; Chan AS; Bertolin A; Chapman DG; King GG
Int J Chron Obstruct Pulmon Dis; 2020; 15():157-166. PubMed ID: 32021155
[TBL] [Abstract][Full Text] [Related]
16. EIT monitors valid and robust regional ventilation distribution in pathologic ventilation states in porcine study using differential DualEnergy-CT (ΔDECT).
Reinartz SD; Imhoff M; Tolba R; Fischer F; Fischer EG; Teschner E; Koch S; Gärber Y; Isfort P; Gremse F
Sci Rep; 2019 Jul; 9(1):9796. PubMed ID: 31278297
[TBL] [Abstract][Full Text] [Related]
17. Impact of exacerbations on respiratory system impedance measured by a forced oscillation technique in COPD: a prospective observational study.
Kamada T; Kaneko M; Tomioka H
Int J Chron Obstruct Pulmon Dis; 2017; 12():509-516. PubMed ID: 28223791
[TBL] [Abstract][Full Text] [Related]
18. Impedance tomography as a new monitoring technique.
Muders T; Luepschen H; Putensen C
Curr Opin Crit Care; 2010 Jun; 16(3):269-75. PubMed ID: 20445445
[TBL] [Abstract][Full Text] [Related]
19. Respiratory system reactance reflects communicating lung volume in chronic obstructive pulmonary disease.
Milne S; Jetmalani K; Chapman DG; Duncan JM; Farah CS; Thamrin C; King GG
J Appl Physiol (1985); 2019 May; 126(5):1223-1231. PubMed ID: 30763164
[TBL] [Abstract][Full Text] [Related]
20. Evaluation of surrogate measures of pulmonary function derived from electrical impedance tomography data in children with cystic fibrosis.
Muller PA; Mueller JL; Mellenthin M; Murthy R; Capps M; Wagner BD; Alsaker M; Deterding R; Sagel SD; Hoppe J
Physiol Meas; 2018 Apr; 39(4):045008. PubMed ID: 29565263
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]