These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

240 related articles for article (PubMed ID: 31563656)

  • 1. Duplex Criteria for Grading of External Carotid Stenosis.
    Shmelev A; Ganti A; Hosseini M; Wilkerson D; Darwazeh G; Zatina M
    Ann Vasc Surg; 2020 Feb; 63():319-324. PubMed ID: 31563656
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Duplex ultrasound velocity criteria for the stented carotid artery.
    Lal BK; Hobson RW; Tofighi B; Kapadia I; Cuadra S; Jamil Z
    J Vasc Surg; 2008 Jan; 47(1):63-73. PubMed ID: 18178455
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Peak systolic velocity and color aliasing are important in the development of duplex ultrasound criteria for external carotid artery stenosis.
    Kronick MD; Chopra A; Swamy S; Brar V; Jung E; Abraham CZ; Liem TK; Landry GJ; Moneta GL
    J Vasc Surg; 2020 Sep; 72(3):951-957. PubMed ID: 31964570
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Predictive multivariate regression to increase the specificity of carotid duplex ultrasound for high-grade stenosis in asymptomatic patients.
    Carnicelli AP; Stone JJ; Doyle A; Chowdhry A; Gillespie DL; Chandra A
    Ann Vasc Surg; 2014 Aug; 28(6):1548-55. PubMed ID: 24530716
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Optimal carotid duplex velocity criteria for defining the severity of carotid in-stent restenosis.
    AbuRahma AF; Abu-Halimah S; Bensenhaver J; Dean LS; Keiffer T; Emmett M; Flaherty S
    J Vasc Surg; 2008 Sep; 48(3):589-94. PubMed ID: 18586444
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Reappraisal of velocity criteria for carotid bulb/internal carotid artery stenosis utilizing high-resolution B-mode ultrasound validated with computed tomography angiography.
    Shaalan WE; Wahlgren CM; Desai T; Piano G; Skelly C; Bassiouny HS
    J Vasc Surg; 2008 Jul; 48(1):104-12; discussion 112-3. PubMed ID: 18486416
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Carotid artery duplex velocity criteria might be equivocal after left ventricular assist device implantation.
    Kronfli A; Atnip RG; Aziz F
    J Vasc Surg; 2021 Nov; 74(5):1609-1617.e1. PubMed ID: 33957226
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The critical role of the external carotid artery in cerebral perfusion of patients with total occlusion of the internal carotid artery.
    Dalainas I; Avgerinos ED; Daskalopoulos ME; Papapetrou A; Papasideris CP; Katsikas V; Xiromeritis K; Moulakakis K; Gianakopoulos T; Liapis CD
    Int Angiol; 2012 Feb; 31(1):16-21. PubMed ID: 22330620
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Detection of internal carotid artery stenosis with duplex velocity criteria using receiver operating characteristic analysis.
    Chua HC; Sitoh YY; Earnest A; Venketasubramanian N
    Ann Acad Med Singap; 2007 Apr; 36(4):247-52. PubMed ID: 17483853
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Carotid artery stenting: is there a need to revise ultrasound velocity criteria?
    Lal BK; Hobson RW; Goldstein J; Chakhtoura EY; Durán WN
    J Vasc Surg; 2004 Jan; 39(1):58-66. PubMed ID: 14718815
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Critical appraisal of the Carotid Duplex Consensus criteria in the diagnosis of carotid artery stenosis.
    AbuRahma AF; Srivastava M; Stone PA; Mousa AY; Jain A; Dean LS; Keiffer T; Emmett M
    J Vasc Surg; 2011 Jan; 53(1):53-9; discussion 59-60. PubMed ID: 20951536
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Center specific duplex Doppler threshold values in carotid artery stenosis].
    Yurdakul M; Tola M; Ozdemir E; Işiksalan Ozbülbül N; Cumhur T
    Tani Girisim Radyol; 2004 Jun; 10(2):167-72. PubMed ID: 15236136
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Predictive ability of duplex ultrasonography for internal carotid artery stenosis of 70%-99%: a comparative study.
    Chen JC; Salvian AJ; Taylor DC; Teal PA; Marotta TR; Hsiang YN
    Ann Vasc Surg; 1998 May; 12(3):244-7. PubMed ID: 9588510
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Importance of validation of accuracy of duplex ultrasonography in identifying moderate and severe carotid artery stenosis.
    Shakhnovich I; Kiser D; Satiani B
    Vasc Endovascular Surg; 2010 Aug; 44(6):483-8. PubMed ID: 20843967
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Determining in-stent stenosis of carotid arteries by duplex ultrasound criteria.
    Stanziale SF; Wholey MH; Boules TN; Selzer F; Makaroun MS
    J Endovasc Ther; 2005 Jun; 12(3):346-53. PubMed ID: 15943510
    [TBL] [Abstract][Full Text] [Related]  

  • 16. B-mode ultrasound measurement of carotid bifurcation stenoses: is it reliable?
    MacKenzie KS; French-Sherry E; Burns K; Pooley T; Bassiouny HS
    Vasc Endovascular Surg; 2002; 36(2):123-35. PubMed ID: 11951099
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Carotid duplex ultrasound changes associated with left ventricular assist devices.
    Coutsoumpos A; Patel S; Teruya TH; Chiriano J; Bianchi C; Abou-Zamzam AM
    Ann Vasc Surg; 2014 May; 28(4):1030.e7-1030.e11. PubMed ID: 24440186
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Progression of moderate-to-severe carotid disease.
    Winter WK; Zorach BB; Arpin PA; Nelson J; Mackey WC
    J Vasc Surg; 2016 Jun; 63(6):1505-10. PubMed ID: 27019947
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Validation of ultrasound parameters to assess collateral flow via ophthalmic artery in internal carotid artery occlusion.
    Tanaka T; Doijiri R; Saito K; Kajimoto K; Ihara M; Yamagami H; Miyashita K; Nagatsuka K
    J Stroke Cerebrovasc Dis; 2014; 23(5):1177-82. PubMed ID: 24268102
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Carotid duplex criteria for a 60% or greater angiographic stenosis: variation according to equipment.
    Fillinger MF; Baker RJ; Zwolak RM; Musson A; Lenz JE; Mott J; Bech FR; Walsh DB; Cronenwett JL
    J Vasc Surg; 1996 Nov; 24(5):856-64. PubMed ID: 8918334
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.