These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. Effect of artificial pancreas systems on glycaemic control in patients with type 1 diabetes: a systematic review and meta-analysis of outpatient randomised controlled trials. Weisman A; Bai JW; Cardinez M; Kramer CK; Perkins BA Lancet Diabetes Endocrinol; 2017 Jul; 5(7):501-512. PubMed ID: 28533136 [TBL] [Abstract][Full Text] [Related]
3. Safe glycemic management during closed-loop treatment of type 1 diabetes: the role of glucagon, use of multiple sensors, and compensation for stress hyperglycemia. Ward WK; Castle JR; El Youssef J J Diabetes Sci Technol; 2011 Nov; 5(6):1373-80. PubMed ID: 22226254 [TBL] [Abstract][Full Text] [Related]
4. Comparison of dual-hormone artificial pancreas, single-hormone artificial pancreas, and conventional insulin pump therapy for glycaemic control in patients with type 1 diabetes: an open-label randomised controlled crossover trial. Haidar A; Legault L; Messier V; Mitre TM; Leroux C; Rabasa-Lhoret R Lancet Diabetes Endocrinol; 2015 Jan; 3(1):17-26. PubMed ID: 25434967 [TBL] [Abstract][Full Text] [Related]
5. Outpatient overnight glucose control with dual-hormone artificial pancreas, single-hormone artificial pancreas, or conventional insulin pump therapy in children and adolescents with type 1 diabetes: an open-label, randomised controlled trial. Haidar A; Legault L; Matteau-Pelletier L; Messier V; Dallaire M; Ladouceur M; Rabasa-Lhoret R Lancet Diabetes Endocrinol; 2015 Aug; 3(8):595-604. PubMed ID: 26066705 [TBL] [Abstract][Full Text] [Related]
6. Artificial pancreas treatment for outpatients with type 1 diabetes: systematic review and meta-analysis. Bekiari E; Kitsios K; Thabit H; Tauschmann M; Athanasiadou E; Karagiannis T; Haidich AB; Hovorka R; Tsapas A BMJ; 2018 Apr; 361():k1310. PubMed ID: 29669716 [TBL] [Abstract][Full Text] [Related]
8. Randomized Outpatient Trial of Single- and Dual-Hormone Closed-Loop Systems That Adapt to Exercise Using Wearable Sensors. Castle JR; El Youssef J; Wilson LM; Reddy R; Resalat N; Branigan D; Ramsey K; Leitschuh J; Rajhbeharrysingh U; Senf B; Sugerman SM; Gabo V; Jacobs PG Diabetes Care; 2018 Jul; 41(7):1471-1477. PubMed ID: 29752345 [TBL] [Abstract][Full Text] [Related]
9. The "Glucositter" overnight automated closed loop system for type 1 diabetes: a randomized crossover trial. Nimri R; Danne T; Kordonouri O; Atlas E; Bratina N; Biester T; Avbelj M; Miller S; Muller I; Phillip M; Battelino T Pediatr Diabetes; 2013 May; 14(3):159-67. PubMed ID: 23448393 [TBL] [Abstract][Full Text] [Related]
10. The challenges of achieving postprandial glucose control using closed-loop systems in patients with type 1 diabetes. Gingras V; Taleb N; Roy-Fleming A; Legault L; Rabasa-Lhoret R Diabetes Obes Metab; 2018 Feb; 20(2):245-256. PubMed ID: 28675686 [TBL] [Abstract][Full Text] [Related]
11. Efficacy of single-hormone and dual-hormone artificial pancreas during continuous and interval exercise in adult patients with type 1 diabetes: randomised controlled crossover trial. Taleb N; Emami A; Suppere C; Messier V; Legault L; Ladouceur M; Chiasson JL; Haidar A; Rabasa-Lhoret R Diabetologia; 2016 Dec; 59(12):2561-2571. PubMed ID: 27704167 [TBL] [Abstract][Full Text] [Related]
12. Single- and Dual-Hormone Artificial Pancreas for Overnight Glucose Control in Type 1 Diabetes. Haidar A; Rabasa-Lhoret R; Legault L; Lovblom LE; Rakheja R; Messier V; D'Aoust É; Falappa CM; Justice T; Orszag A; Tschirhart H; Dallaire M; Ladouceur M; Perkins BA J Clin Endocrinol Metab; 2016 Jan; 101(1):214-23. PubMed ID: 26523526 [TBL] [Abstract][Full Text] [Related]
14. Overnight Glucose Control with Dual- and Single-Hormone Artificial Pancreas in Type 1 Diabetes with Hypoglycemia Unawareness: A Randomized Controlled Trial. Abitbol A; Rabasa-Lhoret R; Messier V; Legault L; Smaoui M; Cohen N; Haidar A Diabetes Technol Ther; 2018 Mar; 20(3):189-196. PubMed ID: 29393675 [TBL] [Abstract][Full Text] [Related]
15. Fully automated closed-loop insulin delivery versus semiautomated hybrid control in pediatric patients with type 1 diabetes using an artificial pancreas. Weinzimer SA; Steil GM; Swan KL; Dziura J; Kurtz N; Tamborlane WV Diabetes Care; 2008 May; 31(5):934-9. PubMed ID: 18252903 [TBL] [Abstract][Full Text] [Related]
16. Progress of artificial pancreas devices towards clinical use: the first outpatient studies. Russell SJ Curr Opin Endocrinol Diabetes Obes; 2015 Apr; 22(2):106-11. PubMed ID: 25692927 [TBL] [Abstract][Full Text] [Related]
17. Effectiveness of artificial pancreas in the non-adult population: A systematic review and network meta-analysis. Karageorgiou V; Papaioannou TG; Bellos I; Alexandraki K; Tentolouris N; Stefanadis C; Chrousos GP; Tousoulis D Metabolism; 2019 Jan; 90():20-30. PubMed ID: 30321535 [TBL] [Abstract][Full Text] [Related]
18. The artificial pancreas: current status and future prospects in the management of diabetes. Peyser T; Dassau E; Breton M; Skyler JS Ann N Y Acad Sci; 2014 Apr; 1311():102-23. PubMed ID: 24725149 [TBL] [Abstract][Full Text] [Related]
19. First Outpatient Clinical Trial of a Full Closed-Loop Artificial Pancreas System in South America. Garelli F; Fushimi E; Rosales N; Arambarri D; Mendoza L; Serafini MC; Moscoso-Vásquez M; Stasi M; Duette P; García-Arabehety J; Giunta JN; De Battista H; Sánchez-Peña R; Grosembacher L J Diabetes Sci Technol; 2023 Jul; 17(4):1008-1015. PubMed ID: 35549733 [TBL] [Abstract][Full Text] [Related]
20. Fully Closed-Loop Multiple Model Probabilistic Predictive Controller Artificial Pancreas Performance in Adolescents and Adults in a Supervised Hotel Setting. Forlenza GP; Cameron FM; Ly TT; Lam D; Howsmon DP; Baysal N; Kulina G; Messer L; Clinton P; Levister C; Patek SD; Levy CJ; Wadwa RP; Maahs DM; Bequette BW; Buckingham BA Diabetes Technol Ther; 2018 May; 20(5):335-343. PubMed ID: 29658779 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]