BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

357 related articles for article (PubMed ID: 31571481)

  • 1. Electrochemiluminescence Immunosensor Based on Au Nanocluster and Hybridization Chain Reaction Signal Amplification for Ultrasensitive Detection of Cardiac Troponin I.
    Zhu L; Ye J; Yan M; Zhu Q; Wang S; Huang J; Yang X
    ACS Sens; 2019 Oct; 4(10):2778-2785. PubMed ID: 31571481
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A wavelength-resolved electrochemiluminescence resonance energy transfer ratiometric immunosensor for detection of cardiac troponin I.
    Zhu L; Ye J; Yan M; Zhu Q; Yang X
    Analyst; 2019 Nov; 144(22):6554-6560. PubMed ID: 31576385
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Reduced graphene oxide-gold nanoparticles-catalase-based dual signal amplification strategy in a spatial-resolved ratiometric electrochemiluminescence immunoassay.
    Cao JT; Fu XL; Liu FR; Ren SW; Liu YM
    Analyst; 2019 Dec; 145(1):91-96. PubMed ID: 31742265
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A renewable and ultrasensitive electrochemiluminescence immunosenor based on magnetic RuL@SiO2-Au~RuL-Ab2 sandwich-type nano-immunocomplexes.
    Gan N; Hou J; Hu F; Cao Y; Li T; Guo Z; Wang J
    Sensors (Basel); 2011; 11(8):7749-62. PubMed ID: 22164043
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Thionin functionalized signal amplification label derived dual-mode electrochemical immunoassay for sensitive detection of cardiac troponin I.
    Lv H; Li Y; Zhang X; Li X; Xu Z; Chen L; Li D; Dong Y
    Biosens Bioelectron; 2019 May; 133():72-78. PubMed ID: 30909015
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Label-free electrochemiluminescence immunosensor for cardiac troponin I using luminol functionalized gold nanoparticles as a sensing platform.
    Li F; Yu Y; Cui H; Yang D; Bian Z
    Analyst; 2013 Mar; 138(6):1844-50. PubMed ID: 23377497
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Ultrasensitive enzyme-free electrochemical immunosensor based on hybridization chain reaction triggered double strand DNA@Au nanoparticle tag.
    Ge Y; Wu J; Ju H; Wu S
    Talanta; 2014 Mar; 120():218-23. PubMed ID: 24468362
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Electrochemical immunosensor for highly sensitive detection of cTnI via in-situ initiated ROP signal amplification strategy.
    Cheng D; Zhou Z; Shang S; Wang H; Guan H; Yang H; Liu Y
    Anal Chim Acta; 2022 Aug; 1219():340032. PubMed ID: 35715132
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Ultrasensitive electrochemiluminescent detection of cardiac troponin I based on a self-enhanced Ru(II) complex.
    Zhou Y; Zhuo Y; Liao N; Chai Y; Yuan R
    Talanta; 2014 Nov; 129():219-26. PubMed ID: 25127587
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Nanoparticle-based electrochemiluminescence immunosensor with enhanced sensitivity for cardiac troponin I using N-(aminobutyl)-N-(ethylisoluminol)-functionalized gold nanoparticles as labels.
    Shen W; Tian D; Cui H; Yang D; Bian Z
    Biosens Bioelectron; 2011 Sep; 27(1):18-24. PubMed ID: 21752633
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Ultrasensitive sandwich-type immunosensor for cardiac troponin I based on enhanced electrocatalytic reduction of H
    Zhang X; Lv H; Li Y; Zhang C; Wang P; Liu Q; Ai B; Xu Z; Zhao Z
    J Mater Chem B; 2019 Mar; 7(9):1460-1468. PubMed ID: 32255017
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Label-free immunosensor for cardiac troponin I detection based on aggregation-induced electrochemiluminescence of a distyrylarylene derivative.
    Yan M; Feng S; Yu L; Xue Y; Huang J; Yang X
    Biosens Bioelectron; 2021 Nov; 192():113532. PubMed ID: 34330035
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A dry chemistry-based ultrasensitive electrochemiluminescence immunosensor for sample-to-answer detection of Cardiac Troponin I.
    Zhan T; Su Y; Lai W; Chen Z; Zhang C
    Biosens Bioelectron; 2022 Oct; 214():114494. PubMed ID: 35779407
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Electrochemical immunosensor based on Au/Co-BDC/MoS
    Zhao H; Du X; Dong H; Jin D; Tang F; Liu Q; Wang P; Chen L; Zhao P; Li Y
    Biosens Bioelectron; 2021 Mar; 175():112883. PubMed ID: 33341318
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A dual signal-amplified electrochemiluminescence immunosensor based on core-shell CeO
    Shao X; Song X; Liu X; Yan L; Liu L; Fan D; Wei Q; Ju H
    Mikrochim Acta; 2021 Sep; 188(10):344. PubMed ID: 34528141
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Mo
    Wang L; Xing B; Ren X; Hu X; Wang H; Wu D; Wei Q
    Biosens Bioelectron; 2020 Feb; 150():111910. PubMed ID: 31784312
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Potential-Resolved Differential Electrochemiluminescence Immunosensor for Cardiac Troponin I Based on MOF-5-Wrapped CdS Quantum Dot Nanoluminophores.
    Du D; Shu J; Guo M; Haghighatbin MA; Yang D; Bian Z; Cui H
    Anal Chem; 2020 Oct; 92(20):14113-14121. PubMed ID: 32962342
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Ultrasensitive Immunosensor for Cardiac Troponin I Detection Based on the Electrochemiluminescence of 2D Ru-MOF Nanosheets.
    Yan M; Ye J; Zhu Q; Zhu L; Huang J; Yang X
    Anal Chem; 2019 Aug; 91(15):10156-10163. PubMed ID: 31283192
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Dual-Wavelength Ratiometric Electrochemiluminescence Immunosensor for Cardiac Troponin I Detection.
    Ye J; Zhu L; Yan M; Zhu Q; Lu Q; Huang J; Cui H; Yang X
    Anal Chem; 2019 Jan; 91(2):1524-1531. PubMed ID: 30547579
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The sandwich-type electrochemiluminescence immunosensor for α-fetoprotein based on enrichment by Fe3O4-Au magnetic nano probes and signal amplification by CdS-Au composite nanoparticles labeled anti-AFP.
    Zhou H; Gan N; Li T; Cao Y; Zeng S; Zheng L; Guo Z
    Anal Chim Acta; 2012 Oct; 746():107-13. PubMed ID: 22975187
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 18.