These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

228 related articles for article (PubMed ID: 31576068)

  • 1. A Model-Based Method for Assessment of Salivary Gland and Planning Target Volume Dosimetry in Volumetric-Modulated Arc Therapy Planning on Head-and-Neck Cancer.
    Zhang H; Cao Y; Antone J; Riegel AC; Ghaly M; Potters L; Jamshidi A
    J Med Phys; 2019; 44(3):201-206. PubMed ID: 31576068
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A dosimetric comparison of the use of equally spaced beam (ESB), beam angle optimization (BAO), and volumetric modulated arc therapy (VMAT) in head and neck cancers treated by intensity modulated radiotherapy.
    Leung WS; Wu VWC; Liu CYW; Cheng ACK
    J Appl Clin Med Phys; 2019 Nov; 20(11):121-130. PubMed ID: 31593367
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effectiveness of Multi-Criteria Optimization-based Trade-Off exploration in combination with RapidPlan for head & neck radiotherapy planning.
    Miguel-Chumacero E; Currie G; Johnston A; Currie S
    Radiat Oncol; 2018 Nov; 13(1):229. PubMed ID: 30470254
    [TBL] [Abstract][Full Text] [Related]  

  • 4. On the gEUD biological optimization objective for organs at risk in Photon Optimizer of Eclipse treatment planning system.
    Fogliata A; Thompson S; Stravato A; Tomatis S; Scorsetti M; Cozzi L
    J Appl Clin Med Phys; 2018 Jan; 19(1):106-114. PubMed ID: 29152846
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Intensity-modulated radiotherapy or volumetric-modulated arc therapy in patients with head and neck cancer: Focus on salivary glands dosimetry.
    Vallard A; Guy JB; Mengue Ndong S; Vial N; Rivoirard R; Auberdiac P; Méry B; Langrand-Escure J; Espenel S; Moncharmont C; Ben Mrad M; Diao P; Goyet D; Magné N
    Head Neck; 2016 Jul; 38(7):1028-34. PubMed ID: 26855006
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparison of organ-at-risk sparing and plan robustness for spot-scanning proton therapy and volumetric modulated arc photon therapy in head-and-neck cancer.
    Barten DL; Tol JP; Dahele M; Slotman BJ; Verbakel WF
    Med Phys; 2015 Nov; 42(11):6589-98. PubMed ID: 26520750
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Detailed evaluation of an automated approach to interactive optimization for volumetric modulated arc therapy plans.
    Tol JP; Dahele M; Delaney AR; Doornaert P; Slotman BJ; Verbakel WF
    Med Phys; 2016 Apr; 43(4):1818. PubMed ID: 27036579
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Improved VMAT planning for head and neck tumors with an advanced optimization algorithm.
    Klippel N; Schmücking M; Terribilini D; Geretschläger A; Aebersold DM; Manser P
    Z Med Phys; 2015 Dec; 25(4):333-340. PubMed ID: 26071076
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Volumetric-modulated arc therapy (VMAT) for whole brain radiotherapy: not only for hippocampal sparing, but also for reduction of dose to organs at risk.
    Sood S; Pokhrel D; McClinton C; Lominska C; Badkul R; Jiang H; Wang F
    Med Dosim; 2017 Winter; 42(4):375-383. PubMed ID: 28822604
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Toward optimal organ at risk sparing in complex volumetric modulated arc therapy: an exponential trade-off with target volume dose homogeneity.
    Tol JP; Dahele M; Doornaert P; Slotman BJ; Verbakel WF
    Med Phys; 2014 Feb; 41(2):021722. PubMed ID: 24506613
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Can knowledge-based DVH predictions be used for automated, individualized quality assurance of radiotherapy treatment plans?
    Tol JP; Dahele M; Delaney AR; Slotman BJ; Verbakel WF
    Radiat Oncol; 2015 Nov; 10():234. PubMed ID: 26584574
    [TBL] [Abstract][Full Text] [Related]  

  • 12.
    Qiu J; Lv B; Fu M; Wang X; Zheng X; Zhuo W
    Head Neck; 2017 Dec; 39(12):2519-2527. PubMed ID: 28963789
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Volumetric modulated arc therapy (VMAT) and simultaneous integrated boost in head-and-neck cancer: is there a place for critical swallowing structures dose sparing?
    Cilla S; Deodato F; Macchia G; Digesù C; Ianiro A; Piermattei A; Valentini V; Morganti AG
    Br J Radiol; 2016; 89(1059):20150764. PubMed ID: 26728543
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Dose-shaping using targeted sparse optimization.
    Sayre GA; Ruan D
    Med Phys; 2013 Jul; 40(7):071711. PubMed ID: 23822415
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Dosimetric Evaluation of Incorporating Patient Geometric Variations Into Adaptive Plan Optimization Through Probabilistic Treatment Planning in Head and Neck Cancers.
    Liu Q; Liang J; Zhou D; Krauss DJ; Chen PY; Yan D
    Int J Radiat Oncol Biol Phys; 2018 Jul; 101(4):985-997. PubMed ID: 29976511
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Poster - Thur Eve - 66: A planning comparison between RapidArc and intensity modulated radiotherapy for head and neck cancer.
    Jiang R; Fleck A; Schaly B; Charland P; Zhan L; Alliet K; Rachakonda R; Osei E
    Med Phys; 2012 Jul; 39(7Part4):4637. PubMed ID: 28516640
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Simultaneous integrated boost intensity-modulated radiotherapy for locally advanced head-and-neck squamous cell carcinomas: II--clinical results.
    Lauve A; Morris M; Schmidt-Ullrich R; Wu Q; Mohan R; Abayomi O; Buck D; Holdford D; Dawson K; Dinardo L; Reiter E
    Int J Radiat Oncol Biol Phys; 2004 Oct; 60(2):374-87. PubMed ID: 15380569
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Assessing the feasibility of volumetric-modulated arc therapy using simultaneous integrated boost (SIB-VMAT): An analysis for complex head-neck, high-risk prostate and rectal cancer cases.
    Cilla S; Deodato F; Digesù C; Macchia G; Picardi V; Ferro M; Sallustio G; De Spirito M; Piermattei A; Morganti AG
    Med Dosim; 2014; 39(1):108-16. PubMed ID: 24342167
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Semiautomated head-and-neck IMRT planning using dose warping and scaling to robustly adapt plans in a knowledge database containing potentially suboptimal plans.
    Schmidt M; Lo JY; Grzetic S; Lutzky C; Brizel DM; Das SK
    Med Phys; 2015 Aug; 42(8):4428-34. PubMed ID: 26233173
    [TBL] [Abstract][Full Text] [Related]  

  • 20. SU-E-T-582: Assessment of Improved Critical Structure Sparing Using Biologically- Based Optimization for Volumetric Modulated Arc Therapy of Head and Neck Cancer.
    Dogan N; Wu Y
    Med Phys; 2012 Jun; 39(6Part19):3839-3840. PubMed ID: 28517050
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.