These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
188 related articles for article (PubMed ID: 31577676)
41. Does Use of a Variable Distal Femur Resection Angle Improve Radiographic Alignment in Primary Total Knee Arthroplasty? Nam D; Vajapey S; Haynes JA; Barrack RL; Nunley RM J Arthroplasty; 2016 Sep; 31(9 Suppl):91-6. PubMed ID: 27084502 [TBL] [Abstract][Full Text] [Related]
42. Alignment in knee flexion position during navigation-assisted total knee arthroplasty. Yang JH; Dahuja A; Kim JK; Yun SH; Yoon JR Knee Surg Sports Traumatol Arthrosc; 2016 Aug; 24(8):2422-9. PubMed ID: 25854497 [TBL] [Abstract][Full Text] [Related]
43. Current practice of orthopaedic surgical skills training raises performance of supervised residents in total knee arthroplasty to levels equal to those of orthopaedic surgeons. Theelen L; Bischoff C; Grimm B; Heyligers IC Perspect Med Educ; 2018 Apr; 7(2):126-132. PubMed ID: 29476426 [TBL] [Abstract][Full Text] [Related]
44. Does final component alignment correlate with alignment of the bone resection surfaces in cemented total knee arthroplasty? Seo SS; Kim CW; Lee CR; Seo JH; Kim DH; Kim OG; Min YK Knee Surg Sports Traumatol Arthrosc; 2018 May; 26(5):1436-1444. PubMed ID: 27826637 [TBL] [Abstract][Full Text] [Related]
45. Comparison of Clinical and Radiological Outcomes of Total Knee Arthroplasty in Osteoarthritic Patients. Singh S; Mehta H; Gupta S; Singh J; Bakshi AS Cureus; 2024 May; 16(5):e60933. PubMed ID: 38910616 [TBL] [Abstract][Full Text] [Related]
46. Postoperative alignment of TKA in patients with severe preoperative varus or valgus deformity: is there a difference between surgical techniques? Rahm S; Camenzind RS; Hingsammer A; Lenz C; Bauer DE; Farshad M; Fucentese SF BMC Musculoskelet Disord; 2017 Jun; 18(1):272. PubMed ID: 28637433 [TBL] [Abstract][Full Text] [Related]
48. Abnormal rate of intraoperative and postoperative implant positioning outliers using "MRI-based patient-specific" compared to "computer assisted" instrumentation in total knee replacement. Ollivier M; Tribot-Laspiere Q; Amzallag J; Boisrenoult P; Pujol N; Beaufils P Knee Surg Sports Traumatol Arthrosc; 2016 Nov; 24(11):3441-3447. PubMed ID: 25994474 [TBL] [Abstract][Full Text] [Related]
49. Neutral alignment leads to higher knee society scores after total knee arthroplasty in preoperatively non-varus patients: a prospective clinical study using 3D-CT. Slevin O; Hirschmann A; Schiapparelli FF; Amsler F; Huegli RW; Hirschmann MT Knee Surg Sports Traumatol Arthrosc; 2018 Jun; 26(6):1602-1609. PubMed ID: 29026941 [TBL] [Abstract][Full Text] [Related]
50. Coronal Correction for Severe Deformity Using Robotic-Assisted Total Knee Arthroplasty. Marchand RC; Sodhi N; Khlopas A; Sultan AA; Higuera CA; Stearns KL; Mont MA J Knee Surg; 2018 Jan; 31(1):2-5. PubMed ID: 29179223 [TBL] [Abstract][Full Text] [Related]
51. Prevalence and predictors of post-operative coronal alignment outliers and their association with the functional outcomes in navigated total knee arthroplasty. Chowdhry M; Bamne AB; Na YG; Kang YG; Kim TK J Arthroplasty; 2014 Dec; 29(12):2357-62. PubMed ID: 25113784 [TBL] [Abstract][Full Text] [Related]
52. Frontal plane alignment after total knee arthroplasty using patient-specific instruments. Daniilidis K; Tibesku CO Int Orthop; 2013 Jan; 37(1):45-50. PubMed ID: 23232654 [TBL] [Abstract][Full Text] [Related]
53. Effect of postoperative mechanical axis alignment on the fifteen-year survival of modern, cemented total knee replacements. Parratte S; Pagnano MW; Trousdale RT; Berry DJ J Bone Joint Surg Am; 2010 Sep; 92(12):2143-9. PubMed ID: 20844155 [TBL] [Abstract][Full Text] [Related]
54. Preoperative valgus deformity has twice the risk of failure as compared to varus deformity after total knee arthroplasty. Mazzotti A; Perna F; Golinelli D; Quattrini I; Stea S; Bordini B; Faldini C Knee Surg Sports Traumatol Arthrosc; 2019 Sep; 27(9):3041-3047. PubMed ID: 30539306 [TBL] [Abstract][Full Text] [Related]
55. Association of surgeon factors with outcome scores after total knee arthroplasty. Tan SC; Chan YH; Chong HC; Chin PL; Yew A; Chia SL; Tay D; Lo NN; Yeo SJ J Orthop Surg (Hong Kong); 2014 Dec; 22(3):378-82. PubMed ID: 25550023 [TBL] [Abstract][Full Text] [Related]
56. Can accuracy of component alignment be improved with Oxford UKA Microplasty® instrumentation? Ng JP; Fan JCH; Lau LCM; Tse TTS; Wan SYC; Hung YW J Orthop Surg Res; 2020 Aug; 15(1):354. PubMed ID: 32843044 [TBL] [Abstract][Full Text] [Related]
57. Technical Considerations and Accuracy Improvement of Accelerometer-Based Portable Computer Navigation for Performing Distal Femoral Resection in Total Knee Arthroplasty. Fujimoto E; Sasashige Y; Nakata K; Yokota G; Omoto T; Ochi M J Arthroplasty; 2017 Jan; 32(1):53-60. PubMed ID: 27365295 [TBL] [Abstract][Full Text] [Related]
58. Favourable alignment outcomes with MRI-based patient-specific instruments in total knee arthroplasty. Schotanus MGM; Thijs E; Heijmans M; Vos R; Kort NP Knee Surg Sports Traumatol Arthrosc; 2018 Sep; 26(9):2659-2668. PubMed ID: 28698929 [TBL] [Abstract][Full Text] [Related]
59. Accuracy and precision in resection alignment: Insights from 10,144 clinical cases using a contemporary computer-assisted total knee arthroplasty system. Dai Y; Bolch C; Jung A; Hamad C; Angibaud L; Stulberg BN; Huddleston JI Knee; 2020 Jun; 27(3):1010-1017. PubMed ID: 32223972 [TBL] [Abstract][Full Text] [Related]
60. Comparison of robot-assisted and conventional total knee arthroplasty: a controlled cadaver study using multiparameter quantitative three-dimensional CT assessment of alignment. Moon YW; Ha CW; Do KH; Kim CY; Han JH; Na SE; Lee CH; Kim JG; Park YS Comput Aided Surg; 2012; 17(2):86-95. PubMed ID: 22348661 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]