These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

267 related articles for article (PubMed ID: 31587955)

  • 1. An exoskeleton controlled by an epidural wireless brain-machine interface in a tetraplegic patient: a proof-of-concept demonstration.
    Benabid AL; Costecalde T; Eliseyev A; Charvet G; Verney A; Karakas S; Foerster M; Lambert A; Morinière B; Abroug N; Schaeffer MC; Moly A; Sauter-Starace F; Ratel D; Moro C; Torres-Martinez N; Langar L; Oddoux M; Polosan M; Pezzani S; Auboiroux V; Aksenova T; Mestais C; Chabardes S
    Lancet Neurol; 2019 Dec; 18(12):1112-1122. PubMed ID: 31587955
    [TBL] [Abstract][Full Text] [Related]  

  • 2. An adaptive closed-loop ECoG decoder for long-term and stable bimanual control of an exoskeleton by a tetraplegic.
    Moly A; Costecalde T; Martel F; Martin M; Larzabal C; Karakas S; Verney A; Charvet G; Chabardes S; Benabid AL; Aksenova T
    J Neural Eng; 2022 Mar; 19(2):. PubMed ID: 35234665
    [No Abstract]   [Full Text] [Related]  

  • 3. Restoration of reaching and grasping movements through brain-controlled muscle stimulation in a person with tetraplegia: a proof-of-concept demonstration.
    Ajiboye AB; Willett FR; Young DR; Memberg WD; Murphy BA; Miller JP; Walter BL; Sweet JA; Hoyen HA; Keith MW; Peckham PH; Simeral JD; Donoghue JP; Hochberg LR; Kirsch RF
    Lancet; 2017 May; 389(10081):1821-1830. PubMed ID: 28363483
    [TBL] [Abstract][Full Text] [Related]  

  • 4. "I Felt the Ball"-The Future of Spine Injury Recovery.
    Sharif S; Ali SM
    World Neurosurg; 2020 Aug; 140():602-613. PubMed ID: 32446984
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Long-term stability of the chronic epidural wireless recorder WIMAGINE in tetraplegic patients.
    Larzabal C; Bonnet S; Costecalde T; Auboiroux V; Charvet G; Chabardes S; Aksenova T; Sauter-Starace F
    J Neural Eng; 2021 Sep; 18(5):. PubMed ID: 34425566
    [No Abstract]   [Full Text] [Related]  

  • 6. CLINATEC® BCI platform based on the ECoG-recording implant WIMAGINE® and the innovative signal-processing: preclinical results.
    Eliseyev A; Mestais C; Charvet G; Sauter F; Abroug N; Arizumi N; Cokgungor S; Costecalde T; Foerster M; Korczowski L; Moriniere B; Porcherot J; Pradal J; Ratel D; Tarrin N; Torres-Martinez N; Verney A; Aksenova T; Benabid AL
    Annu Int Conf IEEE Eng Med Biol Soc; 2014; 2014():1222-5. PubMed ID: 25570185
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Functional electrical stimulation instead of surgery? Improvement of grasping function with FES in a patient with C5 tetraplegia].
    Pfurtscheller J; Rupp R; Müller GR; Fabsits E; Korisek G; Gerner HJ; Pfurtscheller G
    Unfallchirurg; 2005 Jul; 108(7):587-90. PubMed ID: 16025358
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The Berlin Bimanual Test for Tetraplegia (BeBiTT): development, psychometric properties, and sensitivity to change in assistive hand exoskeleton application.
    Angerhöfer C; Vermehren M; Colucci A; Nann M; Koßmehl P; Niedeggen A; Kim WS; Chang WK; Paik NJ; Hömberg V; Soekadar SR
    J Neuroeng Rehabil; 2023 Jan; 20(1):17. PubMed ID: 36707885
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Home Use of a Percutaneous Wireless Intracortical Brain-Computer Interface by Individuals With Tetraplegia.
    Simeral JD; Hosman T; Saab J; Flesher SN; Vilela M; Franco B; Kelemen JN; Brandman DM; Ciancibello JG; Rezaii PG; Eskandar EN; Rosler DM; Shenoy KV; Henderson JM; Nurmikko AV; Hochberg LR
    IEEE Trans Biomed Eng; 2021 Jul; 68(7):2313-2325. PubMed ID: 33784612
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Combining robotic exoskeleton and body weight unweighing technology to promote walking activity in tetraplegia following SCI: A case study.
    Chang SH; Zhu F; Patel N; Afzal T; Kern M; Francisco GE
    J Spinal Cord Med; 2020 Jan; 43(1):126-129. PubMed ID: 30335593
    [No Abstract]   [Full Text] [Related]  

  • 11. The current state of electrocorticography-based brain-computer interfaces.
    Miller KJ; Hermes D; Staff NP
    Neurosurg Focus; 2020 Jul; 49(1):E2. PubMed ID: 32610290
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Hybrid Assistive Limb Exoskeleton HAL in the Rehabilitation of Chronic Spinal Cord Injury: Proof of Concept; the Results in 21 Patients.
    Jansen O; Grasmuecke D; Meindl RC; Tegenthoff M; Schwenkreis P; Sczesny-Kaiser M; Wessling M; Schildhauer TA; Fisahn C; Aach M
    World Neurosurg; 2018 Feb; 110():e73-e78. PubMed ID: 29081392
    [TBL] [Abstract][Full Text] [Related]  

  • 13. An electrocorticographic brain interface in an individual with tetraplegia.
    Wang W; Collinger JL; Degenhart AD; Tyler-Kabara EC; Schwartz AB; Moran DW; Weber DJ; Wodlinger B; Vinjamuri RK; Ashmore RC; Kelly JW; Boninger ML
    PLoS One; 2013; 8(2):e55344. PubMed ID: 23405137
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Clinically Significant Gains in Skillful Grasp Coordination by an Individual With Tetraplegia Using an Implanted Brain-Computer Interface With Forearm Transcutaneous Muscle Stimulation.
    Bockbrader M; Annetta N; Friedenberg D; Schwemmer M; Skomrock N; Colachis S; Zhang M; Bouton C; Rezai A; Sharma G; Mysiw WJ
    Arch Phys Med Rehabil; 2019 Jul; 100(7):1201-1217. PubMed ID: 30902630
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Sensing and decoding the neural drive to paralyzed muscles during attempted movements of a person with tetraplegia using a sleeve array.
    Ting JE; Del Vecchio A; Sarma D; Verma N; Colachis SC; Annetta NV; Collinger JL; Farina D; Weber DJ
    J Neurophysiol; 2021 Dec; 126(6):2104-2118. PubMed ID: 34788156
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Improvement of grasping after motor imagery in C6-C7 tetraplegia: A kinematic and MEG pilot study.
    Mateo S; Di Rienzo F; Reilly KT; Revol P; Delpuech C; Daligault S; Guillot A; Jacquin-Courtois S; Luauté J; Rossetti Y; Collet C; Rode G
    Restor Neurol Neurosci; 2015; 33(4):543-55. PubMed ID: 26409412
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A hybrid BMI-based exoskeleton for paresis: EMG control for assisting arm movements.
    Kawase T; Sakurada T; Koike Y; Kansaku K
    J Neural Eng; 2017 Feb; 14(1):016015. PubMed ID: 28068293
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Results of the first interim analysis of the RAPPER II trial in patients with spinal cord injury: ambulation and functional exercise programs in the REX powered walking aid.
    Birch N; Graham J; Priestley T; Heywood C; Sakel M; Gall A; Nunn A; Signal N
    J Neuroeng Rehabil; 2017 Jun; 14(1):60. PubMed ID: 28629390
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Mobility Outcomes Following Five Training Sessions with a Powered Exoskeleton.
    Hartigan C; Kandilakis C; Dalley S; Clausen M; Wilson E; Morrison S; Etheridge S; Farris R
    Top Spinal Cord Inj Rehabil; 2015; 21(2):93-9. PubMed ID: 26364278
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The effects of gait training using powered lower limb exoskeleton robot on individuals with complete spinal cord injury.
    Wu CH; Mao HF; Hu JS; Wang TY; Tsai YJ; Hsu WL
    J Neuroeng Rehabil; 2018 Mar; 15(1):14. PubMed ID: 29506530
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 14.