These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

160 related articles for article (PubMed ID: 31591698)

  • 21. Biomedical implants and devices: assessment of magnetic field interactions with a 3.0-Tesla MR system.
    Shellock FG
    J Magn Reson Imaging; 2002 Dec; 16(6):721-32. PubMed ID: 12451586
    [TBL] [Abstract][Full Text] [Related]  

  • 22. MRI interactions of a fully implantable pressure monitoring device.
    Stehlin EF; McCormick D; Malpas SC; Pontré BP; Heppner PA; Budgett DM
    J Magn Reson Imaging; 2015 Nov; 42(5):1441-9. PubMed ID: 25865598
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Evaluation of RF heating due to various implants during MR procedures.
    Muranaka H; Horiguchi T; Ueda Y; Tanki N
    Magn Reson Med Sci; 2011; 10(1):11-9. PubMed ID: 21441723
    [TBL] [Abstract][Full Text] [Related]  

  • 24. [Safety of implants in high field and ultrahigh field MRI].
    Kraff O; Quick HH
    Radiologe; 2019 Oct; 59(10):898-905. PubMed ID: 31172246
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Neurostimulation systems: assessment of magnetic field interactions associated with 1.5- and 3-Tesla MR systems.
    Baker KB; Nyenhuis JA; Hrdlicka G; Rezai AR; Tkach JA; Shellock FG
    J Magn Reson Imaging; 2005 Jan; 21(1):72-7. PubMed ID: 15611943
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Standardized MR terminology and reporting of implants and devices as recommended by the American College of Radiology Subcommittee on MR Safety.
    Kanal E; Froelich J; Barkovich AJ; Borgstede J; Bradley W; Gimbel JR; Gosbee J; Greenberg T; Jackson E; Larson P; Lester J; Sebek E; Shellock FG; Weinreb J; Wilkoff BL; Hernandez D;
    Radiology; 2015 Mar; 274(3):866-70. PubMed ID: 25329683
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Magnetic Resonance Safety in the 7T Environment.
    Fagan AJ; Amrami KK; Welker KM; Frick MA; Felmlee JP; Watson RE
    Magn Reson Imaging Clin N Am; 2020 Nov; 28(4):573-582. PubMed ID: 33040997
    [TBL] [Abstract][Full Text] [Related]  

  • 28. A Web-based searchable system to confirm magnetic resonance compatibility of implantable medical devices in Japan: a preliminary study.
    Fujiwara Y; Fujioka H; Watanabe T; Sekiguchi M; Murakami R
    Radiol Phys Technol; 2017 Sep; 10(3):340-348. PubMed ID: 28762005
    [TBL] [Abstract][Full Text] [Related]  

  • 29. MR labeling information for implants and devices: explanation of terminology.
    Shellock FG; Woods TO; Crues JV
    Radiology; 2009 Oct; 253(1):26-30. PubMed ID: 19789253
    [No Abstract]   [Full Text] [Related]  

  • 30. Metallic neurosurgical implants: evaluation of magnetic field interactions, heating, and artifacts at 1.5-Tesla.
    Shellock FG
    J Magn Reson Imaging; 2001 Sep; 14(3):295-9. PubMed ID: 11536406
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Finite volume analysis of temperature effects induced by active MRI implants: 2. Defects on active MRI implants causing hot spots.
    Busch MH; Vollmann W; Grönemeyer DH
    Biomed Eng Online; 2006 May; 5():35. PubMed ID: 16729878
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Virtual Humans for Implantable Device Safety Assessment in MRI: Mitigating Magnetic Resonance Imaging Hazards for Implanted Medical Devices.
    Brown JE; Qiang R; Stadnik PJ; Stotts LJ; Von Arx JA
    IEEE Pulse; 2017; 8(4):50-53. PubMed ID: 28715316
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Magnetic resonance conditionality of abandoned leads from active implantable medical devices at 1.5 T.
    Wang Y; Guo R; Hu W; Zheng J; Wang Q; Jiang J; Kurpad KKN; Kaula N; Long S; Chen J; Kainz W
    Magn Reson Med; 2022 Jan; 87(1):394-408. PubMed ID: 34378816
    [TBL] [Abstract][Full Text] [Related]  

  • 34. RF tissue-heating near metallic implants during magnetic resonance examinations: an approach in the ac limit.
    Ballweg V; Eibofner F; Graf H
    Med Phys; 2011 Oct; 38(10):5522-9. PubMed ID: 21992370
    [TBL] [Abstract][Full Text] [Related]  

  • 35. [Analysis and Evaluation of Magnetic Resonance Compatibility Magnetic Torque Test Method for Implants].
    Wang J; Wang Y; Li F; You Y; Lin L
    Zhongguo Yi Liao Qi Xie Za Zhi; 2022 Nov; 46(6):681-685. PubMed ID: 36597399
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Evaluation of MR issues for the latest standard brands of orthopedic metal implants: plates and screws.
    Zou YF; Chu B; Wang CB; Hu ZY
    Eur J Radiol; 2015 Mar; 84(3):450-457. PubMed ID: 25544555
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Convex optimization of MRI exposure for mitigation of RF-heating from active medical implants.
    Córcoles J; Zastrow E; Kuster N
    Phys Med Biol; 2015 Sep; 60(18):7293-308. PubMed ID: 26350025
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Metallic neurosurgical implants for cranial reconstruction and fixation: assessment of magnetic field interactions, heating and artefacts at 3.0 Tesla.
    Cunningham AS; Harding S; Chatfield DA; Hutchinson P; Carpenter TA; Pickard JD; Menon DK
    Br J Neurosurg; 2005 Apr; 19(2):167-72. PubMed ID: 16120521
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Detection of RF unsafe devices using a parallel transmission MR system.
    Graesslin I; Krueger S; Vernickel P; Achtzehn J; Nehrke K; Weiss S
    Magn Reson Med; 2013 Nov; 70(5):1440-9. PubMed ID: 23203981
    [TBL] [Abstract][Full Text] [Related]  

  • 40. MRI-Related Heating of Implants and Devices: A Review.
    Winter L; Seifert F; Zilberti L; Murbach M; Ittermann B
    J Magn Reson Imaging; 2021 Jun; 53(6):1646-1665. PubMed ID: 32458559
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.