These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

217 related articles for article (PubMed ID: 31591701)

  • 1. On the accuracy of bulk synthetic CT for MR-guided online adaptive radiotherapy.
    Cusumano D; Placidi L; Teodoli S; Boldrini L; Greco F; Longo S; Cellini F; Dinapoli N; Valentini V; De Spirito M; Azario L
    Radiol Med; 2020 Feb; 125(2):157-164. PubMed ID: 31591701
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Dosimetric Accuracy of MR-Guided Online Adaptive Planning for Nasopharyngeal Carcinoma Radiotherapy on 1.5 T MR-Linac.
    Ding S; Liu H; Li Y; Wang B; Li R; Huang X
    Front Oncol; 2022; 12():858076. PubMed ID: 35463359
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Feasibility of MRI-only treatment planning for proton therapy in brain and prostate cancers: Dose calculation accuracy in substitute CT images.
    Koivula L; Wee L; Korhonen J
    Med Phys; 2016 Aug; 43(8):4634. PubMed ID: 27487880
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A deep learning approach to generate synthetic CT in low field MR-guided adaptive radiotherapy for abdominal and pelvic cases.
    Cusumano D; Lenkowicz J; Votta C; Boldrini L; Placidi L; Catucci F; Dinapoli N; Antonelli MV; Romano A; De Luca V; Chiloiro G; Indovina L; Valentini V
    Radiother Oncol; 2020 Dec; 153():205-212. PubMed ID: 33075394
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Deep learning approaches using 2D and 3D convolutional neural networks for generating male pelvic synthetic computed tomography from magnetic resonance imaging.
    Fu J; Yang Y; Singhrao K; Ruan D; Chu FI; Low DA; Lewis JH
    Med Phys; 2019 Sep; 46(9):3788-3798. PubMed ID: 31220353
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Investigating the generalisation of an atlas-based synthetic-CT algorithm to another centre and MR scanner for prostate MR-only radiotherapy.
    Wyatt JJ; Dowling JA; Kelly CG; McKenna J; Johnstone E; Speight R; Henry A; Greer PB; McCallum HM
    Phys Med Biol; 2017 Nov; 62(24):N548-N560. PubMed ID: 29076457
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A Technique to Rapidly Generate Synthetic Computed Tomography for Magnetic Resonance Imaging-Guided Online Adaptive Replanning: An Exploratory Study.
    Ahunbay EE; Thapa R; Chen X; Paulson E; Li XA
    Int J Radiat Oncol Biol Phys; 2019 Apr; 103(5):1261-1270. PubMed ID: 30550817
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Dose evaluation of fast synthetic-CT generation using a generative adversarial network for general pelvis MR-only radiotherapy.
    Maspero M; Savenije MHF; Dinkla AM; Seevinck PR; Intven MPW; Jurgenliemk-Schulz IM; Kerkmeijer LGW; van den Berg CAT
    Phys Med Biol; 2018 Sep; 63(18):185001. PubMed ID: 30109989
    [TBL] [Abstract][Full Text] [Related]  

  • 9. An end-to-end test for MR-guided online adaptive radiotherapy.
    Hoffmans D; Niebuhr N; Bohoudi O; Pfaffenberger A; Palacios M
    Phys Med Biol; 2020 Jun; 65(12):125012. PubMed ID: 32294637
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A multi-institutional analysis of a general pelvis continuous Hounsfield unit synthetic CT software for radiotherapy.
    Yu VY; Keyrilainen J; Suilamo S; Beslimane I; Dresner A; Halkola A; Van der Heide UA; Tyagi N
    J Appl Clin Med Phys; 2021 Mar; 22(3):207-215. PubMed ID: 33616303
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A deep learning approach to generate synthetic CT in low field MR-guided radiotherapy for lung cases.
    Lenkowicz J; Votta C; Nardini M; Quaranta F; Catucci F; Boldrini L; Vagni M; Menna S; Placidi L; Romano A; Chiloiro G; Gambacorta MA; Mattiucci GC; Indovina L; Valentini V; Cusumano D
    Radiother Oncol; 2022 Nov; 176():31-38. PubMed ID: 36063982
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Dosimetric evaluation of synthetic CT relative to bulk density assignment-based magnetic resonance-only approaches for prostate radiotherapy.
    Kim J; Garbarino K; Schultz L; Levin K; Movsas B; Siddiqui MS; Chetty IJ; Glide-Hurst C
    Radiat Oncol; 2015 Nov; 10():239. PubMed ID: 26597251
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Dosimetric evaluation of synthetic CT for head and neck radiotherapy generated by a patch-based three-dimensional convolutional neural network.
    Dinkla AM; Florkow MC; Maspero M; Savenije MHF; Zijlstra F; Doornaert PAH; van Stralen M; Philippens MEP; van den Berg CAT; Seevinck PR
    Med Phys; 2019 Sep; 46(9):4095-4104. PubMed ID: 31206701
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Synthetic CT reconstruction using a deep spatial pyramid convolutional framework for MR-only breast radiotherapy.
    Olberg S; Zhang H; Kennedy WR; Chun J; Rodriguez V; Zoberi I; Thomas MA; Kim JS; Mutic S; Green OL; Park JC
    Med Phys; 2019 Sep; 46(9):4135-4147. PubMed ID: 31309586
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Technical Note: Is bulk electron density assignment appropriate for MRI-only based treatment planning for lung cancer?
    Prior P; Chen X; Gore E; Johnstone C; Li XA
    Med Phys; 2017 Jul; 44(7):3437-3443. PubMed ID: 28391596
    [TBL] [Abstract][Full Text] [Related]  

  • 16. MRI-guided prostate radiation therapy planning: Investigation of dosimetric accuracy of MRI-based dose planning.
    Lambert J; Greer PB; Menk F; Patterson J; Parker J; Dahl K; Gupta S; Capp A; Wratten C; Tang C; Kumar M; Dowling J; Hauville S; Hughes C; Fisher K; Lau P; Denham JW; Salvado O
    Radiother Oncol; 2011 Mar; 98(3):330-4. PubMed ID: 21339009
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Synthetic CT for single-fraction neoadjuvant partial breast irradiation on an MRI-linac.
    Groot Koerkamp ML; de Hond YJM; Maspero M; Kontaxis C; Mandija S; Vasmel JE; Charaghvandi RK; Philippens MEP; van Asselen B; van den Bongard HJGD; Hackett SS; Houweling AC
    Phys Med Biol; 2021 Apr; 66(8):. PubMed ID: 33761491
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A body mass index-based method for "MR-only" abdominal MR-guided adaptive radiotherapy.
    Rippke C; Renkamp CK; Stahl-Arnsberger C; Miltner A; Buchele C; Hörner-Rieber J; Ristau J; Debus J; Alber M; Klüter S
    Z Med Phys; 2023 Feb; ():. PubMed ID: 36759229
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Cone beam CT based validation of neural network generated synthetic CTs for radiotherapy in the head region.
    Irmak S; Zimmermann L; Georg D; Kuess P; Lechner W
    Med Phys; 2021 Aug; 48(8):4560-4571. PubMed ID: 34028053
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Retrospective study comparing MR-guided radiation therapy (MRgRT) setup strategies for prostate treatment: repositioning vs. replanning.
    Kim JI; Park JM; Choi CH; An HJ; Kim YJ; Kim JH
    Radiat Oncol; 2019 Aug; 14(1):139. PubMed ID: 31387593
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.