These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

120 related articles for article (PubMed ID: 31596507)

  • 1. Virtual implantations to transition from porcine to bovine animal models for a total artificial heart.
    Sonntag SJ; Meyns B; Ahn HC; Pahlm F; Hellers G; Najar A; Pieper IL
    Artif Organs; 2020 Apr; 44(4):384-393. PubMed ID: 31596507
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evaluation of the novel total artificial heart Realheart in a pilot human fitting study.
    Pieper IL; Sonntag SJ; Meyns B; Hadi H; Najar A
    Artif Organs; 2020 Feb; 44(2):174-177. PubMed ID: 31339577
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Translation of First North American 50 and 70 cc Total Artificial Heart Virtual and Clinical Implantations: Utility of 3D Computed Tomography to Test Fit Devices.
    Ferng AS; Oliva I; Jokerst C; Avery R; Connell AM; Tran PL; Smith RG; Khalpey Z
    Artif Organs; 2017 Aug; 41(8):727-734. PubMed ID: 27862058
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Anatomic fitting of total artificial hearts for in vivo evaluation.
    Gregory SD; Loechel N; Pearcy MJ; Fraser J; Parnis S; Cohn WE; Timms D
    Artif Organs; 2013 Aug; 37(8):735-41. PubMed ID: 23461712
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Image based evaluation of mediastinal constraints for the development of a pulsatile total artificial heart.
    Fritschi AJ; Laumen M; Spiliopoulos S; Finocchiaro T; Egger C; Schmitz-Rode T; Tenderich G; Koerfer R; Steinseifer U
    Biomed Eng Online; 2013 Aug; 12():81. PubMed ID: 23941400
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Animal studies with the Carmat bioprosthetic total artificial heart.
    Latrémouille C; Duveau D; Cholley B; Zilberstein L; Belbis G; Boughenou MF; Meleard D; Bruneval P; Adam C; Neuschwander A; Perles JC; Jansen P; Carpentier A
    Eur J Cardiothorac Surg; 2015 May; 47(5):e172-8; discussion e178-9. PubMed ID: 25719178
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Anatomical human fitting of the BiVACOR total artificial heart.
    Emmanuel S; Jansz P; McGiffin D; Kure C; Watson A; Connellan M; Granger E; Iyer A; Timms D; Hayward C
    Artif Organs; 2022 Jan; 46(1):50-56. PubMed ID: 34580890
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Hemodynamic characterization of the Realheart® total artificial heart with a hybrid cardiovascular simulator.
    Fresiello L; Najar A; Brynedal Ignell N; Zieliński K; Rocchi M; Meyns B; Perkins IL
    Artif Organs; 2022 Aug; 46(8):1585-1596. PubMed ID: 35231138
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Anatomy of the bovine ascending aorta and brachiocephalic artery found unfavorable for total artificial heart implant.
    Karimov JH; Sunagawa G; Such KA; Sale S; Golding LA; Moazami N; Fukamachi K
    J Artif Organs; 2015 Dec; 18(4):358-60. PubMed ID: 26105105
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Criteria for anatomical compatibility of the total artificial heart: computerized three-dimensional modeling of the cardiovascular anatomy.
    Chatel D; Martin-Bouyer Y; Vicaut E; Bouchoucha H; Achard F; Sablayrolles JL; Carpentier A
    Artif Organs; 1993 Dec; 17(12):1022-35. PubMed ID: 8110069
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Characterization of natural and total artificial heart acceleration.
    Pantalos G; Kim C; Robison P; Everett S; Olsen DB
    ASAIO Trans; 1989; 35(3):235-8. PubMed ID: 2597452
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Novel technique for airless connection of artificial heart to vascular conduits.
    Karimov JH; Gao S; Dessoffy R; Sunagawa G; Sinkewich M; Grady P; Sale S; Moazami N; Fukamachi K
    J Artif Organs; 2017 Dec; 20(4):386-389. PubMed ID: 28761992
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [The contribution of artificial heart research in Czechoslovakia to modern medical science].
    Vasků J
    Bratisl Lek Listy; 1989 Apr; 90(4):235-55. PubMed ID: 2765953
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Prototype Development of an Implantable Compliance Chamber for a Total Artificial Heart.
    Schmitz S; Unthan K; Sedlaczek M; Wald F; Finocchiaro T; Spiliopoulos S; Koerfer R; Steinseifer U
    Artif Organs; 2017 Feb; 41(2):122-129. PubMed ID: 27582339
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Virtual implantation of the 50cc SynCardia total artificial heart.
    Moore RA; Lorts A; Madueme PC; Taylor MD; Morales DL
    J Heart Lung Transplant; 2016 Jun; 35(6):824-7. PubMed ID: 26899766
    [No Abstract]   [Full Text] [Related]  

  • 16. Development of smaller artificial ventricles and valves made by vacuum forming.
    Pantalos GM; Chaing BY; Bishop DN; Perkins PA; Yu LS; Jansen J; Socha PA; Marks JD; Riebman JB; Burns GL
    Int J Artif Organs; 1988 Sep; 11(5):373-80. PubMed ID: 3192315
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Clinical indications for the use of the "Poisk-IOM" total artificial heart: the experience of 13 implantations in humans.
    Shumakov V; Zimin N; Kazakov E; Kormer A; Vorontsov S; Nikolaenko E; Kozlov I; Drobyshev A
    Artif Organs; 1991 Oct; 15(5):372-5. PubMed ID: 1741680
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Three-dimensional thoracic modeling for an anatomical compatibility study of the implantable total artificial heart.
    Zhang B; Masuzawa T; Tatsumi E; Taenaka Y; Uyama C; Takano H; Takamiya M
    Artif Organs; 1999 Mar; 23(3):229-34. PubMed ID: 10198713
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Total artificial heart implantation: clinical indications, expected postoperative imaging findings, and recognition of complications.
    Parker MS; Fahrner LJ; Deuell BP; Olsen KM; Kasirajan V; Shah KB; Medina AE; Doolin KR; de Groot PM; Goodman WC
    AJR Am J Roentgenol; 2014 Mar; 202(3):W191-201. PubMed ID: 24555614
    [TBL] [Abstract][Full Text] [Related]  

  • 20. In vitro hemolytic performance of the Realheart® V11C TAH prototype with porcine blood.
    Perkins IL; Mansisidor EM; Zaman SF; Mudge K; Bodger O; Najar A
    Artif Organs; 2023 Jul; 47(7):1208-1213. PubMed ID: 37032479
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.