BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

720 related articles for article (PubMed ID: 31606957)

  • 1. Validation of a New Point Shear-Wave Elastography Method for Noninvasive Assessment of Liver Fibrosis: A Prospective Multicenter Study.
    Joo I; Kim SY; Park HS; Lee ES; Kang HJ; Lee JM
    Korean J Radiol; 2019 Nov; 20(11):1527-1535. PubMed ID: 31606957
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Which are the cut-off values of 2D-Shear Wave Elastography (2D-SWE) liver stiffness measurements predicting different stages of liver fibrosis, considering Transient Elastography (TE) as the reference method?
    Sporea I; Bota S; Gradinaru-Taşcău O; Sirli R; Popescu A; Jurchiş A
    Eur J Radiol; 2014 Mar; 83(3):e118-22. PubMed ID: 24380640
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Two-Dimensional-Shear Wave Elastography with a Propagation Map: Prospective Evaluation of Liver Fibrosis Using Histopathology as the Reference Standard.
    Lee DH; Lee ES; Lee JY; Bae JS; Kim H; Lee KB; Yu SJ; Cho EJ; Lee JH; Cho YY; Han JK; Choi BI
    Korean J Radiol; 2020 Dec; 21(12):1317-1325. PubMed ID: 32729274
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Performance of 2D-SWE.GE for predicting different stages of liver fibrosis, using Transient Elastography as the reference method.
    Bende F; Sporea I; Sirli R; Popescu A; Mare R; Miutescu B; Lupusoru R; Moga T; Pienar C
    Med Ultrason; 2017 Apr; 19(2):143-149. PubMed ID: 28440347
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparative study between pSWE and 2D-SWE techniques integrated in the same ultrasound machine, with Transient Elastography as the reference method.
    Foncea CG; Popescu A; Lupusoru R; Fofiu R; Sirli R; Danila M; Sporea I
    Med Ultrason; 2020 Mar; 22(1):13-19. PubMed ID: 32096782
    [TBL] [Abstract][Full Text] [Related]  

  • 6. 2D shear wave elastography is better than transient elastography in predicting post-hepatectomy complication after resection.
    Lee DH; Lee ES; Bae JS; Lee JY; Han JK; Yi NJ; Lee KW; Suh KS; Kim H; Lee KB; Choi BI
    Eur Radiol; 2021 Aug; 31(8):5802-5811. PubMed ID: 33459859
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Prospective Validation of Intra- and Interobserver Reproducibility of a New Point Shear Wave Elastographic Technique for Assessing Liver Stiffness in Patients with Chronic Liver Disease.
    Ahn SJ; Lee JM; Chang W; Lee SM; Kang HJ; Yang H; Yoon JH; Park SJ; Han JK
    Korean J Radiol; 2017; 18(6):926-935. PubMed ID: 29089825
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Assessment of liver fibrosis in chronic hepatitis: comparison of shear wave elastography and transient elastography.
    Paul SB; Das P; Mahanta M; Sreenivas V; Kedia S; Kalra N; Kaur H; Vijayvargiya M; Ghosh S; Gamanagatti SR; Shalimar ; Gupta SD; Acharya SK
    Abdom Radiol (NY); 2017 Dec; 42(12):2864-2873. PubMed ID: 28643136
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Two-dimensional Shear Wave Elastography with Propagation Maps for the Assessment of Liver Fibrosis and Clinically Significant Portal Hypertension in Patients with Chronic Liver Disease: A Prospective Study.
    Jeon SK; Lee JM; Joo I; Yoon JH; Lee DH; Han JK
    Acad Radiol; 2020 Jun; 27(6):798-806. PubMed ID: 31494001
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Hepatic fibrosis: prospective comparison of MR elastography and US shear-wave elastography for evaluation.
    Yoon JH; Lee JM; Joo I; Lee ES; Sohn JY; Jang SK; Lee KB; Han JK; Choi BI
    Radiology; 2014 Dec; 273(3):772-82. PubMed ID: 25007047
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Prospective comparison of spleen and liver stiffness by using shear-wave and transient elastography for detection of portal hypertension in cirrhosis.
    Elkrief L; Rautou PE; Ronot M; Lambert S; Dioguardi Burgio M; Francoz C; Plessier A; Durand F; Valla D; Lebrec D; Vilgrain V; Castéra L
    Radiology; 2015 May; 275(2):589-98. PubMed ID: 25469784
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Prospective comparison of transient elastography, point shear wave elastography, APRI and FIB-4 for staging liver fibrosis in chronic viral hepatitis.
    Udompap P; Sukonrut K; Suvannarerg V; Pongpaibul A; Charatcharoenwitthaya P
    J Viral Hepat; 2020 Apr; 27(4):437-448. PubMed ID: 31799740
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Assessing Hepatic Fibrosis Using 2-D Shear Wave Elastography in Patients with Liver Tumors: A Prospective Single-Center Study.
    Huang Z; Zheng W; Zhang YJ; Xu L; Chen JB; Chen JC; Chen MS; Zhou Z
    Ultrasound Med Biol; 2017 Nov; 43(11):2522-2529. PubMed ID: 28807448
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Ultrasound Shear Wave Elastography for Liver Disease. A Critical Appraisal of the Many Actors on the Stage.
    Piscaglia F; Salvatore V; Mulazzani L; Cantisani V; Schiavone C
    Ultraschall Med; 2016 Feb; 37(1):1-5. PubMed ID: 26871407
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison of 2D Shear Wave Elastography, Transient Elastography, and MR Elastography for the Diagnosis of Fibrosis in Patients With Nonalcoholic Fatty Liver Disease.
    Furlan A; Tublin ME; Yu L; Chopra KB; Lippello A; Behari J
    AJR Am J Roentgenol; 2020 Jan; 214(1):W20-W26. PubMed ID: 31714842
    [No Abstract]   [Full Text] [Related]  

  • 16. Interobserver agreement and diagnostic accuracy of shearwave elastography for the staging of hepatitis C virus-associated liver fibrosis.
    Kaposi PN; Unger Z; Fejér B; Kucsa A; Tóth A; Folhoffer A; Szalay F; Bérczi V
    J Clin Ultrasound; 2020 Feb; 48(2):67-74. PubMed ID: 31463955
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Performance of two-dimensional shear wave elastography and transient elastography compared to liver biopsy for staging of liver fibrosis.
    Kovatsch A; Honcharova-Biletska H; Segna D; Steigmiller K; Blümel S; Deibel RA; Kühlewindt T; Leinenkugel G; Müller S; Furrer E; Schawkat K; Reiner CS; Weber A; Müllhaupt B; Scharl M; Gubler C; Jüngst C
    Eur J Clin Invest; 2023 Jul; 53(7):e13980. PubMed ID: 36880934
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The Performance of a 2-Dimensional Shear-Wave Elastography Technique for Predicting Different Stages of Liver Fibrosis Using Transient Elastography as the Control Method.
    Bende F; Sporea I; Şirli R; Nistorescu S; Fofiu R; Bâldea V; Popescu A
    Ultrasound Q; 2020 Nov; 37(2):97-104. PubMed ID: 33136935
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Agreement and accuracy of shear-wave techniques (point shear-wave elastography and 2D-shear-wave elastography) using transient elastography as reference.
    Fernandes F; Piedade J; Freitas G; Area P; Santos R; Grinsztejn B; Veloso V; Pereira G; Perazzo H
    Eur J Gastroenterol Hepatol; 2022 Aug; 34(8):873-881. PubMed ID: 35802529
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Accuracy of real-time shear wave elastography for assessing liver fibrosis in chronic hepatitis C: a pilot study.
    Ferraioli G; Tinelli C; Dal Bello B; Zicchetti M; Filice G; Filice C;
    Hepatology; 2012 Dec; 56(6):2125-33. PubMed ID: 22767302
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 36.