134 related articles for article (PubMed ID: 31610031)
1. Technical Note: Comprehensive evaluation and implementation of two independent methods for beam monitor calibration for proton scanning beam.
Shen J; Ding X; Hu Y; Kang Y; Liu W; Deng W; Bues M
Med Phys; 2019 Dec; 46(12):5867-5875. PubMed ID: 31610031
[TBL] [Abstract][Full Text] [Related]
2. Beam monitor calibration of a synchrotron-based scanned light-ion beam delivery system.
Osorio J; Dreindl R; Grevillot L; Letellier V; Kuess P; Carlino A; Elia A; Stock M; Vatnitsky S; Palmans H
Z Med Phys; 2021 May; 31(2):154-165. PubMed ID: 32747175
[TBL] [Abstract][Full Text] [Related]
3. Dosimetric commissioning and quality assurance of scanned ion beams at the Italian National Center for Oncological Hadrontherapy.
Mirandola A; Molinelli S; Vilches Freixas G; Mairani A; Gallio E; Panizza D; Russo S; Ciocca M; Donetti M; Magro G; Giordanengo S; Orecchia R
Med Phys; 2015 Sep; 42(9):5287-300. PubMed ID: 26328978
[TBL] [Abstract][Full Text] [Related]
4. A procedure to determine the planar integral spot dose values of proton pencil beam spots.
Anand A; Sahoo N; Zhu XR; Sawakuchi GO; Poenisch F; Amos RA; Ciangaru G; Titt U; Suzuki K; Mohan R; Gillin MT
Med Phys; 2012 Feb; 39(2):891-900. PubMed ID: 22320798
[TBL] [Abstract][Full Text] [Related]
5. Dual ring multilayer ionization chamber and theory-based correction technique for scanning proton therapy.
Takayanagi T; Nihongi H; Nishiuchi H; Tadokoro M; Ito Y; Nakashima C; Fujitaka S; Umezawa M; Matsuda K; Sakae T; Terunuma T
Med Phys; 2016 Jul; 43(7):4150. PubMed ID: 27370135
[TBL] [Abstract][Full Text] [Related]
6. Consistency in quality correction factors for ionization chamber dosimetry in scanned proton beam therapy.
Sorriaux J; Testa M; Paganetti H; Bertrand D; Lee JA; Palmans H; Vynckier S; Sterpin E
Med Phys; 2017 Sep; 44(9):4919-4927. PubMed ID: 28656604
[TBL] [Abstract][Full Text] [Related]
7. Gradient corrections for reference dosimetry using Farmer-type ionization chambers in single-layer scanned proton fields.
Palmans H; Medin J; Trnková P; Vatnitsky S
Med Phys; 2020 Dec; 47(12):6531-6539. PubMed ID: 33111370
[TBL] [Abstract][Full Text] [Related]
8. Comparison of multi-institutional Varian ProBeam pencil beam scanning proton beam commissioning data.
Langner UW; Eley JG; Dong L; Langen K
J Appl Clin Med Phys; 2017 May; 18(3):96-107. PubMed ID: 28422381
[TBL] [Abstract][Full Text] [Related]
9. Evaluation of Gafchromic® EBT3 films characteristics in therapy photon, electron and proton beams.
Sorriaux J; Kacperek A; Rossomme S; Lee JA; Bertrand D; Vynckier S; Sterpin E
Phys Med; 2013 Nov; 29(6):599-606. PubMed ID: 23107430
[TBL] [Abstract][Full Text] [Related]
10. Spatially fractionated (GRID) radiation therapy using proton pencil beam scanning (PBS): Feasibility study and clinical implementation.
Gao M; Mohiuddin MM; Hartsell WF; Pankuch M
Med Phys; 2018 Apr; 45(4):1645-1653. PubMed ID: 29431867
[TBL] [Abstract][Full Text] [Related]
11. Proton beam monitor chamber calibration.
Gomà C; Lorentini S; Meer D; Safai S
Phys Med Biol; 2014 Sep; 59(17):4961-71. PubMed ID: 25109620
[TBL] [Abstract][Full Text] [Related]
12. Consistency of Faraday cup and ionization chamber dosimetry of proton fields and the role of nuclear interactions.
Wulff J; Paul A; Bäcker CM; Baumann KS; Esser JN; Koska B; Timmermann B; Verbeek NG; Bäumer C
Med Phys; 2024 Mar; 51(3):2277-2292. PubMed ID: 37991110
[TBL] [Abstract][Full Text] [Related]
13. [Measurement of peak correction factor of Farmer chamber for calibration of flattening filter free (FFF) clinical photon beams].
Kontra G; Major T; Polgár C
Magy Onkol; 2015 Jun; 59(2):119-23. PubMed ID: 26035159
[TBL] [Abstract][Full Text] [Related]
14. Technical Note: Use of commercial multilayer Faraday cup for offline daily beam range verification at the McLaren Proton Therapy Center.
Tesfamicael B; Athar B; Bejarano Buele A; Kozlyuk V; Nichiporov D; Watts DA; Arjomandy B
Med Phys; 2019 Feb; 46(2):1049-1053. PubMed ID: 30570757
[TBL] [Abstract][Full Text] [Related]
15. The effect of spill change on reliable absolute dosimetry in a synchrotron proton spot scanning system.
Tan HQ; Lew KS; Koh CWY; Wibawa A; Master Z; Beltran CJ; Park SY; Furutani KM
Med Phys; 2023 Jul; 50(7):4067-4078. PubMed ID: 37272223
[TBL] [Abstract][Full Text] [Related]
16. Implementation of planar proton minibeam radiation therapy using a pencil beam scanning system: A proof of concept study.
De Marzi L; Patriarca A; Nauraye C; Hierso E; Dendale R; Guardiola C; Prezado Y
Med Phys; 2018 Nov; 45(11):5305-5316. PubMed ID: 30311639
[TBL] [Abstract][Full Text] [Related]
17. Characterization of a high-resolution 2D transmission ion chamber for independent validation of proton pencil beam scanning of conventional and FLASH dose delivery.
Zou W; Diffenderfer ES; Ota K; Boisseau P; Kim MM; Cai Y; Avery SM; Carlson DJ; Wiersma RD; Lin A; Koumenis C; Cengel KA; Metz JM; Dong L; Teo BK
Med Phys; 2021 Jul; 48(7):3948-3957. PubMed ID: 33843065
[TBL] [Abstract][Full Text] [Related]
18. A linear relationship for the LET-dependence of Gafchromic EBT3 film in spot-scanning proton therapy.
Anderson SE; Grams MP; Wan Chan Tseung H; Furutani KM; Beltran CJ
Phys Med Biol; 2019 Mar; 64(5):055015. PubMed ID: 30673655
[TBL] [Abstract][Full Text] [Related]
19. Proton dosimetry intercomparison.
Vatnitsky S; Siebers J; Miller D; Moyers M; Schaefer M; Jones D; Vynckier S; Hayakawa Y; Delacroix S; Isacsson U; Medin J; Kacperek A; Lomax A; Coray A; Kluge H; Heese J; Verhey L; Daftari I; Gall K; Lam G; Beck T; Hartmann G
Radiother Oncol; 1996 Nov; 41(2):169-77. PubMed ID: 9004361
[TBL] [Abstract][Full Text] [Related]
20. Design and commissioning of the non-dedicated scanning proton beamline for ocular treatment at the synchrotron-based CNAO facility.
Ciocca M; Magro G; Mastella E; Mairani A; Mirandola A; Molinelli S; Russo S; Vai A; Fiore MR; Mosci C; Valvo F; Via R; Baroni G; Orecchia R
Med Phys; 2019 Apr; 46(4):1852-1862. PubMed ID: 30659616
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]