These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

119 related articles for article (PubMed ID: 31610166)

  • 1. Mitral Valve Replacement With a Third-Generation Porcine Valve: An Italian Multicentered Study.
    Lorusso R; Miceli A; Gelsomino S; Lio A; Parise O; Montisci A; Vizzardi E; Pacini D; Di Bartolomeo R; Renzulli A; Serraino FG; Comoglio C; Liberi R; Martinelli G; Sciangula A; Mazzola A; Faragalli F; De Bonis M; Taramasso M; Alfieri O; Caimmi P; Micalizzi E; Mercogliano D; Demicheli G; Celiento M; Bortolotti U; Solinas M; Glauber M
    Ann Thorac Surg; 2020 Jun; 109(6):1865-1872. PubMed ID: 31610166
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Hemodynamic performance of the Medtronic Mosaic porcine bioprosthesis up to ten years.
    Riess FC; Bader R; Cramer E; Hansen L; Kleijnen B; Wahl G; Wallrath J; Winkel S; Bleese N
    Ann Thorac Surg; 2007 Apr; 83(4):1310-8. PubMed ID: 17383332
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Clinical results of the Medtronic Mosaic porcine bioprosthesis up to 13 years.
    Riess FC; Cramer E; Hansen L; Schiffelers S; Wahl G; Wallrath J; Winkel S; Kremer P
    Eur J Cardiothorac Surg; 2010 Jan; 37(1):145-53. PubMed ID: 19695889
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Carpentier-Edwards standard porcine bioprosthesis: clinical performance to seventeen years.
    Jamieson WR; Munro AI; Miyagishima RT; Allen P; Burr LH; Tyers GF
    Ann Thorac Surg; 1995 Oct; 60(4):999-1006; discussion 1007. PubMed ID: 7575007
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Long-Term Outcomes of Mosaic Versus Perimount Mitral Replacements: 17-Year Follow-Up of 940 Implants.
    Beute TJ; Goehler M; Parker J; Boeve T; Heiser J; Murphy E; Timek T; Willekes CL
    Ann Thorac Surg; 2020 Aug; 110(2):508-515. PubMed ID: 31866480
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Medtronic mosaic porcine bioprosthesis: investigational center experience to six years.
    Jamieson WR; Fradet GJ; MacNab JS; Burr LH; Stanford EA; Janusz MT; Abel JG; Germann E; Cheung A
    J Heart Valve Dis; 2005 Jan; 14(1):54-63. PubMed ID: 15700437
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The Mosaic Mitral Valve Bioprosthesis: A Long-Term Clinical and Hemodynamic Follow-Up.
    Celiento M; Blasi S; De Martino A; Pratali S; Milano AD; Bortolotti U
    Tex Heart Inst J; 2016 Feb; 43(1):13-9. PubMed ID: 27047280
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Seventeen-year experience with the St. Jude medical biocor porcine bioprosthesis.
    Mykén PS
    J Heart Valve Dis; 2005 Jul; 14(4):486-92. PubMed ID: 16116875
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Hemodynamic and clinical performance of the 25-mm Medtronic Mosaic porcine bioprosthesis in the mitral position.
    Takagi K; Arinaga K; Takaseya T; Otsuka H; Shojima T; Shintani Y; Kono T; Zaima Y; Kikusaki S; Saku K; Tayama E
    J Artif Organs; 2022 Mar; 25(1):34-41. PubMed ID: 34023940
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Fifteen years follow up with the St. Jude Medical Biocor porcine bioprosthesis.
    Mykén P; Bech-Hanssen O; Phipps B; Caidahl K
    J Heart Valve Dis; 2000 May; 9(3):415-22. PubMed ID: 10888100
    [TBL] [Abstract][Full Text] [Related]  

  • 11. "Mosaic" medtronic bioprosthetic valve replacement clinical results and hemodynamical performance.
    Jasinski MJ; Kadziola Z; Keal R; Sosnowski AW
    J Cardiovasc Surg (Torino); 2000 Apr; 41(2):181-6. PubMed ID: 10901519
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Long-term follow up of patients undergoing reoperative surgery with aortic or mitral valve replacement using a St. Jude Medical prosthesis.
    Emery RW; Krogh CC; McAdams S; Emery AM; Holter AR
    J Heart Valve Dis; 2010 Jul; 19(4):473-84. PubMed ID: 20845896
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Medtronic Mosaic porcine bioprosthesis: assessment of 12-year performance.
    Jamieson WR; Riess FC; Raudkivi PJ; Metras J; Busse EF; Goldstein J; Fradet GJ
    J Thorac Cardiovasc Surg; 2011 Aug; 142(2):302-7.e2. PubMed ID: 21277591
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Aortic and mitral valve replacement with the Carpentier-Edwards pericardial bioprosthesis: 10-year results.
    Murakami T; Eishi K; Nakano S; Kobayashi J; Sasako Y; Isobe F; Kosakai Y; Kito Y; Kawashima Y
    J Heart Valve Dis; 1996 Jan; 5(1):45-9. PubMed ID: 8834725
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Medtronic Intact porcine bioprosthesis experience to twelve years.
    Jamieson WR; Lemieux MD; Sullivan JA; Munro IA; Métras J; Cartier PC
    Ann Thorac Surg; 2001 May; 71(5 Suppl):S278-81. PubMed ID: 11388204
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Mid-term results after Epic xenograft implantation for aortic, mitral, and double valve replacement.
    Lehmann S; Walther T; Leontjev S; Kempfert J; Rastan A; Garbade J; Borger MA; Falk V; Mohr FW
    J Heart Valve Dis; 2007 Nov; 16(6):641-8; discussion 648. PubMed ID: 18095514
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Eighteen-year follow up after Hancock II bioprosthesis insertion.
    Legarra JJ; Llorens R; Catalan M; Segura I; Trenor AM; de Buruaga JS; Rabago G; Sarralde A
    J Heart Valve Dis; 1999 Jan; 8(1):16-24. PubMed ID: 10096477
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Long-term durability of the Hancock II porcine bioprosthesis.
    Rizzoli G; Bottio T; Thiene G; Toscano G; Casarotto D
    J Thorac Cardiovasc Surg; 2003 Jul; 126(1):66-74. PubMed ID: 12878940
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The St. Jude Medical cardiac valve prosthesis: a 25-year experience with single valve replacement.
    Emery RW; Krogh CC; Arom KV; Emery AM; Benyo-Albrecht K; Joyce LD; Nicoloff DM
    Ann Thorac Surg; 2005 Mar; 79(3):776-82; discussion 782-3. PubMed ID: 15734375
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The Mosaic bioprosthesis in the aortic position: 17 years' results.
    Gansera B; Hapfelmeier A; Brandl K; Spiliopoulos K; Gundling F; Eichinger W
    Thorac Cardiovasc Surg; 2014 Feb; 62(1):26-34. PubMed ID: 23817772
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.