These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

192 related articles for article (PubMed ID: 31617078)

  • 1. Haemodynamics Study of Tapered Stents Intervention to Tapered Arteries.
    Shen X; Jiang J; Deng Y; Zhu H; Lu K
    Cardiovasc Eng Technol; 2019 Dec; 10(4):583-589. PubMed ID: 31617078
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Alterations in regional vascular geometry produced by theoretical stent implantation influence distributions of wall shear stress: analysis of a curved coronary artery using 3D computational fluid dynamics modeling.
    LaDisa JF; Olson LE; Douglas HA; Warltier DC; Kersten JR; Pagel PS
    Biomed Eng Online; 2006 Jun; 5():40. PubMed ID: 16780592
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The conical stent in coronary artery improves hemodynamics compared with the traditional cylindrical stent.
    Yu Y; Zhou Y; Ma Q; Jia S; Wu S; Sun Y; Liu X; Zhao Y; Liu Y; Shi D
    Int J Cardiol; 2017 Jan; 227():166-171. PubMed ID: 27863293
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparative study of tapered versus conventional cylindrical balloon for stent implantation in stenotic tapered artery.
    Shen X; Jiang J; Zhu H; Lu K; Dong P; Gu L
    Artif Organs; 2020 Jul; 44(7):727-735. PubMed ID: 32017159
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Local Hemodynamic Forces After Stenting: Implications on Restenosis and Thrombosis.
    Ng J; Bourantas CV; Torii R; Ang HY; Tenekecioglu E; Serruys PW; Foin N
    Arterioscler Thromb Vasc Biol; 2017 Dec; 37(12):2231-2242. PubMed ID: 29122816
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Effect of different expansion strategies on coronary stent deployment in a tapered artery.
    Shen X; Ji S; Xie Z; Deng Y
    Technol Health Care; 2017 Jul; 25(S1):21-28. PubMed ID: 28582888
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Mis-sizing of stent promotes intimal hyperplasia: impact of endothelial shear and intramural stress.
    Chen HY; Sinha AK; Choy JS; Zheng H; Sturek M; Bigelow B; Bhatt DL; Kassab GS
    Am J Physiol Heart Circ Physiol; 2011 Dec; 301(6):H2254-63. PubMed ID: 21926337
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Predictors for functionally significant in-stent restenosis: an integrated analysis using coronary angiography, IVUS, and myocardial perfusion imaging.
    Kang SJ; Cho YR; Park GM; Ahn JM; Han SB; Lee JY; Kim WJ; Park DW; Lee SW; Kim YH; Lee CW; Park SW; Mintz GS; Park SJ
    JACC Cardiovasc Imaging; 2013 Nov; 6(11):1183-90. PubMed ID: 24229771
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Behaviour of two typical stents towards a new stent evolution.
    Simão M; Ferreira JM; Mora-Rodriguez J; Fragata J; Ramos HM
    Med Biol Eng Comput; 2017 Jun; 55(6):1019-1037. PubMed ID: 27669700
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Local hemodynamic changes caused by main branch stent implantation and subsequent virtual side branch balloon angioplasty in a representative coronary bifurcation.
    Williams AR; Koo BK; Gundert TJ; Fitzgerald PJ; LaDisa JF
    J Appl Physiol (1985); 2010 Aug; 109(2):532-40. PubMed ID: 20507966
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Impact of coronary anatomy and stenting technique on long-term outcome after drug-eluting stent implantation for unprotected left main coronary artery disease.
    Tiroch K; Mehilli J; Byrne RA; Schulz S; Massberg S; Laugwitz KL; Vorpahl M; Seyfarth M; Kastrati A;
    JACC Cardiovasc Interv; 2014 Jan; 7(1):29-36. PubMed ID: 24332416
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Evaluation of potential substrates for restenosis and thrombosis in overlapped versus edge-to-edge juxtaposed bioabsorbable scaffolds: Insights from a computed fluid dynamic study.
    Rigatelli G; Zuin M; Dell'Avvocata F; Cardaioli P; Vassiliev D; Ferenc M; Nghia NT; Nguyen T; Foin N
    Cardiovasc Revasc Med; 2018 Apr; 19(3 Pt A):273-278. PubMed ID: 28918876
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Wall shear stress in the development of in-stent restenosis revisited. A critical review of clinical data on shear stress after intracoronary stent implantation.
    Jenei C; Balogh E; Szabó GT; Dézsi CA; Kőszegi Z
    Cardiol J; 2016; 23(4):365-73. PubMed ID: 27439365
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Uncertainty Quantification of a Multiscale Model for In-Stent Restenosis.
    Nikishova A; Veen L; Zun P; Hoekstra AG
    Cardiovasc Eng Technol; 2018 Dec; 9(4):761-774. PubMed ID: 30136082
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Assessment of the effects of increasing levels of physiological realism in the computational fluid dynamics analyses of implanted coronary stents.
    Murphy J; Boyle F
    Annu Int Conf IEEE Eng Med Biol Soc; 2008; 2008():5906-9. PubMed ID: 19164062
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Hemodynamics in stented vertebral artery ostial stenosis based on computational fluid dynamics simulations.
    Qiao A; Dai X; Niu J; Jiao L
    Comput Methods Biomech Biomed Engin; 2016; 19(11):1190-200. PubMed ID: 26691981
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Computational fluid dynamics analysis of balloon-expandable coronary stents: influence of stent and vessel deformation.
    Martin DM; Murphy EA; Boyle FJ
    Med Eng Phys; 2014 Aug; 36(8):1047-56. PubMed ID: 24953569
    [TBL] [Abstract][Full Text] [Related]  

  • 18. An experimental-nonlinear finite element study of a balloon expandable stent inside a realistic stenotic human coronary artery to investigate plaque and arterial wall injury.
    Karimi A; Razaghi R; Shojaei A; Navidbakhsh M
    Biomed Tech (Berl); 2015 Dec; 60(6):593-602. PubMed ID: 25870956
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Developing pulsatile flow in a deployed coronary stent.
    Rajamohan D; Banerjee RK; Back LH; Ibrahim AA; Jog MA
    J Biomech Eng; 2006 Jun; 128(3):347-59. PubMed ID: 16706584
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Computational fluid dynamics study of common stent models inside idealised curved coronary arteries.
    Chen WX; Poon EK; Hutchins N; Thondapu V; Barlis P; Ooi A
    Comput Methods Biomech Biomed Engin; 2017 May; 20(6):671-681. PubMed ID: 28349764
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.