BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

180 related articles for article (PubMed ID: 31621435)

  • 1. Model predictive control for MR-HIFU-mediated, uniform hyperthermia.
    Sebeke L; Deenen DA; Maljaars E; Heijman E; de Jager B; Heemels WPMH; Grüll H
    Int J Hyperthermia; 2019; 36(1):1040-1050. PubMed ID: 31621435
    [No Abstract]   [Full Text] [Related]  

  • 2. Visualization of thermal washout due to spatiotemporally heterogenous perfusion in the application of a model-based control algorithm for MR-HIFU mediated hyperthermia.
    Sebeke LC; Rademann P; Maul AC; Yeo SY; Castillo Gómez JD; Deenen DA; Schmidt P; de Jager B; Heemels WPMH; Grüll H; Heijman E
    Int J Hyperthermia; 2021; 38(1):1174-1187. PubMed ID: 34374624
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Interleaved Mapping of Temperature and Longitudinal Relaxation Rate to Monitor Drug Delivery During Magnetic Resonance-Guided High-Intensity Focused Ultrasound-Induced Hyperthermia.
    Kneepkens E; Heijman E; Keupp J; Weiss S; Nicolay K; Grüll H
    Invest Radiol; 2017 Oct; 52(10):620-630. PubMed ID: 28598900
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Reduction of peak acoustic pressure and shaping of heated region by use of multifoci sonications in MR-guided high-intensity focused ultrasound mediated mild hyperthermia.
    Partanen A; Tillander M; Yarmolenko PS; Wood BJ; Dreher MR; Kohler MO
    Med Phys; 2013 Jan; 40(1):013301. PubMed ID: 23298120
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Mild hyperthermia by MR-guided focused ultrasound in an ex vivo model of osteolytic bone tumour: optimization of the spatio-temporal control of the delivered temperature.
    Guillemin PC; Gui L; Lorton O; Zilli T; Crowe LA; Desgranges S; Montet X; Terraz S; Miralbell R; Salomir R; Boudabbous S
    J Transl Med; 2019 Oct; 17(1):350. PubMed ID: 31651311
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Magnetic Resonance-Guided High-Intensity Focused Ultrasound Hyperthermia for Recurrent Rectal Cancer: MR Thermometry Evaluation and Preclinical Validation.
    Chu W; Staruch RM; Pichardo S; Tillander M; Köhler MO; Huang Y; Ylihautala M; McGuffin M; Czarnota G; Hynynen K
    Int J Radiat Oncol Biol Phys; 2016 Jul; 95(4):1259-67. PubMed ID: 27209510
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Mild hyperthermia with magnetic resonance-guided high-intensity focused ultrasound for applications in drug delivery.
    Partanen A; Yarmolenko PS; Viitala A; Appanaboyina S; Haemmerich D; Ranjan A; Jacobs G; Woods D; Enholm J; Wood BJ; Dreher MR
    Int J Hyperthermia; 2012; 28(4):320-36. PubMed ID: 22621734
    [TBL] [Abstract][Full Text] [Related]  

  • 8. High intensity focused ultrasound induced in vivo large volume hyperthermia under 3D MRI temperature control.
    Tillander M; Hokland S; Koskela J; Dam H; Andersen NP; Pedersen M; Tanderup K; Ylihautala M; Köhler M
    Med Phys; 2016 Mar; 43(3):1539-49. PubMed ID: 26936737
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Endocavitary thermal therapy by MRI-guided phased-array contact ultrasound: experimental and numerical studies on the multi-input single-output PID temperature controller's convergence and stability.
    Salomir R; Rata M; Cadis D; Petrusca L; Auboiroux V; Cotton F
    Med Phys; 2009 Oct; 36(10):4726-41. PubMed ID: 19928104
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Model-based feasibility assessment and evaluation of prostate hyperthermia with a commercial MR-guided endorectal HIFU ablation array.
    Salgaonkar VA; Prakash P; Rieke V; Ozhinsky E; Plata J; Kurhanewicz J; Hsu IC; Diederich CJ
    Med Phys; 2014 Mar; 41(3):033301. PubMed ID: 24593742
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Drift correction for accurate PRF-shift MR thermometry during mild hyperthermia treatments with MR-HIFU.
    Bing C; Staruch RM; Tillander M; Köhler MO; Mougenot C; Ylihautala M; Laetsch TW; Chopra R
    Int J Hyperthermia; 2016 Sep; 32(6):673-87. PubMed ID: 27210733
    [TBL] [Abstract][Full Text] [Related]  

  • 12. An adaptive targeting algorithm for magnetic resonance-guided high-intensity focused ultrasound controlled hyperthermia.
    Wong SM; Luo P; Keunen B; Pichardo S; Drake JM; Waspe AC
    Med Phys; 2023 Jun; 50(6):3347-3358. PubMed ID: 37058533
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Thermal combination therapies for local drug delivery by magnetic resonance-guided high-intensity focused ultrasound.
    Hijnen N; Kneepkens E; de Smet M; Langereis S; Heijman E; Grüll H
    Proc Natl Acad Sci U S A; 2017 Jun; 114(24):E4802-E4811. PubMed ID: 28566498
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Breath-hold MR-HIFU hyperthermia: phantom and
    Bing C; Cheng B; Staruch RM; Nofiele J; Wodzak Staruch M; Szczepanski D; Farrow-Gillespie A; Yang A; Laetsch TW; Chopra R
    Int J Hyperthermia; 2019; 36(1):1084-1097. PubMed ID: 31707872
    [No Abstract]   [Full Text] [Related]  

  • 15. Tissue-mimicking thermochromic phantom for characterization of HIFU devices and applications.
    Eranki A; Mikhail AS; Negussie AH; Katti PS; Wood BJ; Partanen A
    Int J Hyperthermia; 2019; 36(1):518-529. PubMed ID: 31046513
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Hyperthermia-mediated doxorubicin release from thermosensitive liposomes using MR-HIFU: therapeutic effect in rabbit Vx2 tumours.
    Staruch RM; Hynynen K; Chopra R
    Int J Hyperthermia; 2015 Mar; 31(2):118-33. PubMed ID: 25582131
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Magnetic resonance imaging for the exploitation of bubble-enhanced heating by high-intensity focused ultrasound: a feasibility study in ex vivo liver.
    Elbes D; Denost Q; Robert B; Köhler MO; Tanter M; Bruno Q
    Ultrasound Med Biol; 2014 May; 40(5):956-64. PubMed ID: 24462160
    [TBL] [Abstract][Full Text] [Related]  

  • 18. In vivo optimisation study for multi-baseline MR-based thermometry in the context of hyperthermia using MR-guided high intensity focused ultrasound for head and neck applications.
    Pichardo S; Köhler M; Lee J; Hynnyen K
    Int J Hyperthermia; 2014 Dec; 30(8):579-92. PubMed ID: 25430989
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Advances in MR image-guided high-intensity focused ultrasound therapy.
    Kim YS
    Int J Hyperthermia; 2015 May; 31(3):225-32. PubMed ID: 25373687
    [TBL] [Abstract][Full Text] [Related]  

  • 20. In vivo characterization of tissue thermal properties of the kidney during local hyperthermia induced by MR-guided high-intensity focused ultrasound.
    Cornelis F; Grenier N; Moonen CT; Quesson B
    NMR Biomed; 2011 Aug; 24(7):799-806. PubMed ID: 21834004
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.