These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

108 related articles for article (PubMed ID: 31625338)

  • 21. Fluorodeoxyglucose positron emission tomography/magnetic resonance imaging: current status, future aspects.
    Rakheja R; Chandarana H; Ponzo F; Seltzer AL; Beltran LS; Geppert C; Friedman KP
    PET Clin; 2014 Apr; 9(2):237-52. PubMed ID: 25030285
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Development of PET/MRI with insertable PET for simultaneous PET and MR imaging of human brain.
    Jung JH; Choi Y; Jung J; Kim S; Lim HK; Im KC; Oh CH; Park HW; Kim KM; Kim JG
    Med Phys; 2015 May; 42(5):2354-63. PubMed ID: 25979030
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Clinical positron emission tomography/magnetic resonance imaging applications.
    von Schulthess GK; Kuhn FP; Kaufmann P; Veit-Haibach P
    Semin Nucl Med; 2013 Jan; 43(1):3-10. PubMed ID: 23178084
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Performance measurements of the Siemens mMR integrated whole-body PET/MR scanner.
    Delso G; Fürst S; Jakoby B; Ladebeck R; Ganter C; Nekolla SG; Schwaiger M; Ziegler SI
    J Nucl Med; 2011 Dec; 52(12):1914-22. PubMed ID: 22080447
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Correlation of simultaneously acquired diffusion-weighted imaging and 2-deoxy-[18F] fluoro-2-D-glucose positron emission tomography of pulmonary lesions in a dedicated whole-body magnetic resonance/positron emission tomography system.
    Schmidt H; Brendle C; Schraml C; Martirosian P; Bezrukov I; Hetzel J; Müller M; Sauter A; Claussen CD; Pfannenberg C; Schwenzer NF
    Invest Radiol; 2013 May; 48(5):247-55. PubMed ID: 23519008
    [TBL] [Abstract][Full Text] [Related]  

  • 26. PET/MRI: challenges, solutions and perspectives.
    Herzog H
    Z Med Phys; 2012 Dec; 22(4):281-98. PubMed ID: 22925652
    [TBL] [Abstract][Full Text] [Related]  

  • 27. PET/MR imaging: technical aspects and potential clinical applications.
    Torigian DA; Zaidi H; Kwee TC; Saboury B; Udupa JK; Cho ZH; Alavi A
    Radiology; 2013 Apr; 267(1):26-44. PubMed ID: 23525716
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Quality control for quantitative multicenter whole-body PET/MR studies: A NEMA image quality phantom study with three current PET/MR systems.
    Boellaard R; Rausch I; Beyer T; Delso G; Yaqub M; Quick HH; Sattler B
    Med Phys; 2015 Oct; 42(10):5961-9. PubMed ID: 26429271
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Systematic evaluation of phantom fluids for simultaneous PET/MR hybrid imaging.
    Ziegler S; Braun H; Ritt P; Hocke C; Kuwert T; Quick HH
    J Nucl Med; 2013 Aug; 54(8):1464-71. PubMed ID: 23792278
    [TBL] [Abstract][Full Text] [Related]  

  • 30. GATE Monte Carlo simulations for variations of an integrated PET/MR hybrid imaging system based on the Biograph mMR model.
    Aklan B; Jakoby BW; Watson CC; Braun H; Ritt P; Quick HH
    Phys Med Biol; 2015 Jun; 60(12):4731-52. PubMed ID: 26040657
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Why buy a PET/MR for high end research?
    von Schulthess GK
    J Magn Reson Imaging; 2014 Aug; 40(2):283-4. PubMed ID: 24115270
    [No Abstract]   [Full Text] [Related]  

  • 32. Simultaneous acquisition of multislice PET and MR images: initial results with a MR-compatible PET scanner.
    Catana C; Wu Y; Judenhofer MS; Qi J; Pichler BJ; Cherry SR
    J Nucl Med; 2006 Dec; 47(12):1968-76. PubMed ID: 17138739
    [TBL] [Abstract][Full Text] [Related]  

  • 33. PET/MR: the molecular imaging dream team.
    Maniawski P
    Nucl Med Rev Cent East Eur; 2011; 14(1):47-50. PubMed ID: 21751176
    [No Abstract]   [Full Text] [Related]  

  • 34. Impact of flexible body surface coil and patient table on PET quantification and image quality in integrated PET/MR.
    Fürst S; Souvatzoglou M; Martinez-Möller A; Schwaiger M; Nekolla SG; Ziegler SI
    Nuklearmedizin; 2014; 53(3):79-87. PubMed ID: 24658368
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Evaluation of a positron emission tomography (PET)-compatible field-cycled MRI (FCMRI) scanner.
    Gilbert KM; Scholl TJ; Handler WB; Alford JK; Chronik BA
    Magn Reson Med; 2009 Oct; 62(4):1017-25. PubMed ID: 19585601
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Pulmonary imaging using respiratory motion compensated simultaneous PET/MR.
    Dutta J; Huang C; Li Q; El Fakhri G
    Med Phys; 2015 Jul; 42(7):4227-40. PubMed ID: 26133621
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Evaluation of feasibility and image quality of 68Ga-DOTATOC positron emission tomography/magnetic resonance in comparison with positron emission tomography/computed tomography in patients with neuroendocrine tumors.
    Gaertner FC; Beer AJ; Souvatzoglou M; Eiber M; Fürst S; Ziegler SI; Brohl F; Schwaiger M; Scheidhauer K
    Invest Radiol; 2013 May; 48(5):263-72. PubMed ID: 23385399
    [TBL] [Abstract][Full Text] [Related]  

  • 38. PET/MR images acquired with a compact MR-compatible PET detector in a 7-T magnet.
    Judenhofer MS; Catana C; Swann BK; Siegel SB; Jung WI; Nutt RE; Cherry SR; Claussen CD; Pichler BJ
    Radiology; 2007 Sep; 244(3):807-14. PubMed ID: 17709830
    [TBL] [Abstract][Full Text] [Related]  

  • 39. A pivotal time for hybrid PET/MR imaging technology.
    Zaidi H
    J Am Coll Radiol; 2013 Nov; 10(11):878-81. PubMed ID: 24183554
    [No Abstract]   [Full Text] [Related]  

  • 40. Attenuation correction for PET/MR: problems, novel approaches and practical solutions.
    Martinez-Möller A; Nekolla SG
    Z Med Phys; 2012 Dec; 22(4):299-310. PubMed ID: 22925653
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.