These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

115 related articles for article (PubMed ID: 3163240)

  • 1. [Hypoxia secondary to the failure of an oxygen-air-nitrous oxide mixer].
    Michon-Boyer-Chammard F; Fischler M; Douau PY; Vourc'h G
    Ann Fr Anesth Reanim; 1988; 7(2):165-7. PubMed ID: 3163240
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Distribution of a hypoxic gas mixture by retro-pollution of a medical gas distribution system].
    Gorce P; Crisan A; Gondret R; Viallard ML; Clergue F
    Ann Fr Anesth Reanim; 1994; 13(5):741-4. PubMed ID: 7733527
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Pollution and retro-pollution by the distribution system of medical gases].
    Otteni JC; Ancellin J; Cazalaà JB; Clergue F
    Ann Fr Anesth Reanim; 1994; 13(5):713-25. PubMed ID: 7733522
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Delivery of an hypoxic gas mixture due to a defective rubber seal of a flowmeter control tube.
    Hay H
    Eur J Anaesthesiol; 2000 Jul; 17(7):456-8. PubMed ID: 10964148
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Selective oxygen leak. A potential cause of patient hypoxia.
    Williams AR; Hilton PJ
    Anaesthesia; 1986 Nov; 41(11):1133-4. PubMed ID: 2947514
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Hypoxic gas flow caused by malfunction of the proportioning system of anesthesia machines.
    Ishikawa S; Nakazawa K; Makita K
    Anesth Analg; 2002 Jun; 94(6):1672. PubMed ID: 12032057
    [No Abstract]   [Full Text] [Related]  

  • 7. Nitrous oxide-oxygen administration: when safety features no longer are safe.
    Donaldson M; Donaldson D; Quarnstrom FC
    J Am Dent Assoc; 2012 Feb; 143(2):134-43. PubMed ID: 22298554
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A simplified concept for controlling oxygen mixtures in the anaesthetic machine--better, cheaper and more user-friendly?
    Berge JA; Gramstad L; Grimnes S
    Acta Anaesthesiol Scand; 1995 May; 39(4):563-7. PubMed ID: 7676800
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Back to basics--a simplified non-mathematical approach to low flow techniques in anaesthesia.
    Baker AB
    Anaesth Intensive Care; 1994 Aug; 22(4):394-5. PubMed ID: 7978203
    [No Abstract]   [Full Text] [Related]  

  • 10. Hypoxia due to air in the oxygen pipeline. A case for oxygen monitoring in theatre.
    Thorp JM; Railton R
    Anaesthesia; 1982 Jun; 37(6):683-7. PubMed ID: 7091626
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Hypoxia with a third flowmeter tube on the anaesthetic machine.
    Russell WJ; Ward JB
    Anaesth Intensive Care; 1978 Nov; 6(4):355-7. PubMed ID: 153717
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Arterial blood gases before, during, and after nitrous oxide:oxygen administration.
    Stewart RD; Gorayeb MJ; Pelton GH
    Ann Emerg Med; 1986 Oct; 15(10):1177-80. PubMed ID: 3092705
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Defective gas mixers, a cause of retro-pollution of medical gas distribution pipelines].
    Otteni JC; Ancellin J; Cazalaà JB
    Ann Fr Anesth Reanim; 1997; 16(1):68-72. PubMed ID: 9686101
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Air contamination of a closed anesthesia circuit.
    Mizuno K; Sumiyoshi R
    Acta Anaesthesiol Scand; 1998 Jan; 42(1):128-30. PubMed ID: 9527735
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Arterial oxygen saturation during induction of anaesthesia.
    Thorpe CM; Gauntlett IS
    Anaesthesia; 1990 Dec; 45(12):1012-5. PubMed ID: 2278322
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Noninvasive assessment of diffusion hypoxia following administration of nitrous oxide-oxygen.
    Jeske AH; Whitmire CW; Freels C; Fuentes M
    Anesth Prog; 2004; 51(1):10-3. PubMed ID: 15106684
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Respiratory and anesthetic gas flow monitoring].
    Günther H; Helbig P; Völker HU
    Anaesthesiol Reanim; 1987; 12(4):213-8. PubMed ID: 3477234
    [No Abstract]   [Full Text] [Related]  

  • 18. Physical properties of nitrous oxide-oxygen sedation equipment used in dentistry.
    Hallonsten AL; Löfström JB
    Swed Dent J; 1982; 6(4):133-48. PubMed ID: 6817427
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Oxygen delivery failure resulting from interference with a Bain breathing system.
    Hay H
    Eur J Anaesthesiol; 2000 Sep; 17(9):591-3. PubMed ID: 11029128
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Transposition of rotameter tubes.
    Chadwick DA
    Anesthesiology; 1974 Jan; 40(1):102. PubMed ID: 4520944
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 6.