These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

186 related articles for article (PubMed ID: 31640169)

  • 1. Two-Wired Active Spring-Loaded Dry Electrodes for EEG Measurements.
    Lee S; Shin Y; Kumar A; Kim K; Lee HN
    Sensors (Basel); 2019 Oct; 19(20):. PubMed ID: 31640169
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A Two-Wired Ultra-High Input Impedance Active Electrode.
    Guerrero FN; Spinelli EM
    IEEE Trans Biomed Circuits Syst; 2018 Apr; 12(2):437-445. PubMed ID: 29570069
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Novel active comb-shaped dry electrode for EEG measurement in hairy site.
    Huang YJ; Wu CY; Wong AM; Lin BS
    IEEE Trans Biomed Eng; 2015 Jan; 62(1):256-63. PubMed ID: 25137719
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Micropower non-contact EEG electrode with active common-mode noise suppression and input capacitance cancellation.
    Chi YM; Cauwenberghs G
    Annu Int Conf IEEE Eng Med Biol Soc; 2009; 2009():4218-21. PubMed ID: 19964104
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Design, fabrication and experimental validation of a novel dry-contact sensor for measuring electroencephalography signals without skin preparation.
    Liao LD; Wang IJ; Chen SF; Chang JY; Lin CT
    Sensors (Basel); 2011; 11(6):5819-34. PubMed ID: 22163929
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Polyvinyl alcohol/polyacrylamide double-network hydrogel-based semi-dry electrodes for robust electroencephalography recording at hairy scalp for noninvasive brain-computer interfaces.
    Li G; Liu Y; Chen Y; Li M; Song J; Li K; Zhang Y; Hu L; Qi X; Wan X; Liu J; He Q; Zhou H
    J Neural Eng; 2023 Mar; 20(2):. PubMed ID: 36863014
    [No Abstract]   [Full Text] [Related]  

  • 7. Design Principles and Dynamic Front End Reconfiguration for Low Noise EEG Acquisition With Finger Based Dry Electrodes.
    Nathan V; Jafari R
    IEEE Trans Biomed Circuits Syst; 2015 Oct; 9(5):631-40. PubMed ID: 26462239
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Active Claw-Shaped Dry Electrodes for EEG Measurement in Hair Areas.
    Wang Z; Ding Y; Yuan W; Chen H; Chen W; Chen C
    Bioengineering (Basel); 2024 Mar; 11(3):. PubMed ID: 38534550
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Active Electrodes for Wearable EEG Acquisition: Review and Electronics Design Methodology.
    Xu J; Mitra S; Van Hoof C; Yazicioglu RF; Makinwa KAA
    IEEE Rev Biomed Eng; 2017; 10():187-198. PubMed ID: 28113349
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A 0.67 μV-IIRN super-T Ω-Z
    Dabbaghian A; El-Hajj Y; Ghalamboran M; Grau G; Kassiri H
    IEEE Trans Biomed Circuits Syst; 2024 Feb; 18(1):3-15. PubMed ID: 37535484
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Self-Adhesive and Capacitive Carbon Nanotube-Based Electrode to Record Electroencephalograph Signals From the Hairy Scalp.
    Lee SM; Kim JH; Park C; Hwang JY; Hong JS; Lee KH; Lee SH
    IEEE Trans Biomed Eng; 2016 Jan; 63(1):138-47. PubMed ID: 26390442
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Two-Wired Current Modulator Active Electrode for Ambulatory Biosignal Recording.
    Pourahmad A; Dehghani R
    IEEE Trans Biomed Circuits Syst; 2019 Feb; 13(1):15-25. PubMed ID: 30575548
    [TBL] [Abstract][Full Text] [Related]  

  • 13. High and dry? Comparing active dry EEG electrodes to active and passive wet electrodes.
    Mathewson KE; Harrison TJ; Kizuk SA
    Psychophysiology; 2017 Jan; 54(1):74-82. PubMed ID: 28000254
    [TBL] [Abstract][Full Text] [Related]  

  • 14. In-service characterization of a polymer wick-based quasi-dry electrode for rapid pasteless electroencephalography.
    Pedrosa P; Fiedler P; Pestana V; Vasconcelos B; Gaspar H; Amaral MH; Freitas D; Haueisen J; Nóbrega JM; Fonseca C
    Biomed Tech (Berl); 2018 Jul; 63(4):349-359. PubMed ID: 28467306
    [TBL] [Abstract][Full Text] [Related]  

  • 15. 3D Printable Dry EEG Electrodes with Coiled-Spring Prongs.
    Kimura M; Nakatani S; Nishida SI; Taketoshi D; Araki N
    Sensors (Basel); 2020 Aug; 20(17):. PubMed ID: 32825762
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Active electrode IC for EEG and electrical impedance tomography with continuous monitoring of contact impedance.
    Guermandi M; Cardu R; Franchi Scarselli E; Guerrieri R
    IEEE Trans Biomed Circuits Syst; 2015 Feb; 9(1):21-33. PubMed ID: 24860040
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [High resolution EEG and whole head MEG].
    Scheer HJ; Burghoff M
    Biomed Tech (Berl); 2002; 47 Suppl 1 Pt 2():564-5. PubMed ID: 12465238
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Determining the input impedance of ECG amplifiers using accurate electrode modelling.
    Maji S; Burke MJ
    Biomed Phys Eng Express; 2020 Jan; 6(1):015030. PubMed ID: 33438618
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Preamplifiers for non-contact capacitive biopotential measurements.
    Peng G; Ignjatovic Z; Bocko MF
    Annu Int Conf IEEE Eng Med Biol Soc; 2013; 2013():1482-5. PubMed ID: 24109979
    [TBL] [Abstract][Full Text] [Related]  

  • 20. An Inflatable and Wearable Wireless System for Making 32-Channel Electroencephalogram Measurements.
    Yu YH; Lu SW; Chuang CH; King JT; Chang CL; Chen SA; Chen SF; Lin CT
    IEEE Trans Neural Syst Rehabil Eng; 2016 Jul; 24(7):806-13. PubMed ID: 26780814
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.