BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

186 related articles for article (PubMed ID: 31647178)

  • 1. Implications of hydrodynamic testing to guide sizing of self-expanding transcatheter heart valves for valve-in-valve procedures.
    Sathananthan J; Hensey M; Fraser R; Landes U; Blanke P; Hatoum H; Dasi LP; Sedaghat A; Bapat VN; Leipsic J; Søndergaard L; Wood DA; Webb JG
    Catheter Cardiovasc Interv; 2020 Sep; 96(3):E332-E340. PubMed ID: 31647178
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A bench test study of bioprosthetic valve fracture performed before versus after transcatheter valve-in-valve intervention.
    Sathananthan J; Fraser R; Hatoum H; Barlow AM; Stanová V; Allen KB; Chhatriwalla AK; Rieu R; Pibarot P; Dasi LP; Søndergaard L; Wood DA; Webb JG
    EuroIntervention; 2020 Mar; 15(16):1409-1416. PubMed ID: 31854302
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Valve-in-Valve Transcatheter Aortic Valve Replacement and Bioprosthetic Valve Fracture Comparing Different Transcatheter Heart Valve Designs: An Ex Vivo Bench Study.
    Sathananthan J; Sellers S; Barlow AM; Stanová V; Fraser R; Toggweiler S; Allen KB; Chhatriwalla A; Murdoch DJ; Hensey M; Lau K; Alkhodair A; Dvir D; Asgar AW; Cheung A; Blanke P; Ye J; Rieu R; Pibarot P; Wood D; Leipsic J; Webb JG
    JACC Cardiovasc Interv; 2019 Jan; 12(1):65-75. PubMed ID: 30621980
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Effect of transcatheter aortic valve size and position on valve-in-valve hemodynamics: An in vitro study.
    Azadani AN; Reardon M; Simonato M; Aldea G; Nickenig G; Kornowski R; Dvir D
    J Thorac Cardiovasc Surg; 2017 Jun; 153(6):1303-1315.e1. PubMed ID: 28283233
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Impact of implant depth on hydrodynamic function with the ACURATE
    Sathananthan J; Sellers SL; Fraser R; Dvir D; Hensey M; Murdoch DJ; Blanke P; Pibarot P; Toggweiler S; Wood D; Leipsic J; Webb JG
    EuroIntervention; 2019 May; 15(1):78-87. PubMed ID: 30479308
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Impact of implant depth on hydrodynamic function of the ALLEGRA bioprosthesis in valve-in-valve interventions.
    Sathananthan J; Fraser R; Kütting M; Hensey M; Landes U; Alkhodair A; Sedaghat A; Blanke P; Toggweiler S; Leipsic J; Søndergaard L; Wood D; Webb JG
    EuroIntervention; 2020 Feb; 15(15):e1335-e1342. PubMed ID: 31607682
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Transcatheter Replacement of Failed Bioprosthetic Valves: Large Multicenter Assessment of the Effect of Implantation Depth on Hemodynamics After Aortic Valve-in-Valve.
    Simonato M; Webb J; Kornowski R; Vahanian A; Frerker C; Nissen H; Bleiziffer S; Duncan A; Rodés-Cabau J; Attizzani GF; Horlick E; Latib A; Bekeredjian R; Barbanti M; Lefevre T; Cerillo A; Hernández JM; Bruschi G; Spargias K; Iadanza A; Brecker S; Palma JH; Finkelstein A; Abdel-Wahab M; Lemos P; Petronio AS; Champagnac D; Sinning JM; Salizzoni S; Napodano M; Fiorina C; Marzocchi A; Leon M; Dvir D
    Circ Cardiovasc Interv; 2016 Jun; 9(6):. PubMed ID: 27301396
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Impact of Commissural Misalignment on Hydrodynamic Function Following Valve-in-Valve Intervention With the ACURATE neo.
    Meier D; Akodad M; Chatfield AG; Lutter G; Puehler T; Søndergaard L; Wood DA; Webb JG; Sellers SL; Sathananthan J
    JACC Cardiovasc Interv; 2022 Aug; 15(15):1532-1539. PubMed ID: 35926920
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Bioprosthetic Valve Leaflet Displacement During Valve-in-Valve Intervention: An Ex Vivo Bench Study.
    Hensey M; Sellers S; Sathananthan J; Lai A; Landes U; Alkhodair A; McManus B; Cheung A; Wood D; Blanke P; Leipsic J; Ye J; Webb J
    JACC Cardiovasc Interv; 2020 Mar; 13(6):667-678. PubMed ID: 32113932
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Bioprosthetic Valve Fracture Improves the Hemodynamic Results of Valve-in-Valve Transcatheter Aortic Valve Replacement.
    Chhatriwalla AK; Allen KB; Saxon JT; Cohen DJ; Aggarwal S; Hart AJ; Baron SJ; Dvir D; Borkon AM
    Circ Cardiovasc Interv; 2017 Jul; 10(7):. PubMed ID: 28698291
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Fracture of small Mitroflow® aortic bioprosthesis following valve-in-valve transcatheter aortic valve replacement with ACURATE neo valve-From bench testing to clinical practice.
    Amat-Santos IJ; Gutiérrez H; Sathananthan J; Webb JG
    Catheter Cardiovasc Interv; 2020 Mar; 95(4):E120-E122. PubMed ID: 31140682
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Repeat transcatheter aortic valve implantation and implications for transcatheter heart valve performance: insights from bench testing.
    Sathananthan J; Fraser R; Landes U; Rich C; Sellers SL; Leipsic J; Blanke P; Lutter G; Frank D; Puehler T; Wood DA; Søndergaard L; Webb JG
    EuroIntervention; 2021 Nov; 17(10):856-864. PubMed ID: 33495142
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Redo Transcatheter Aortic Valve Implantation with the ALLEGRA Transcatheter Heart Valve: Insights from Bench Testing.
    Akodad M; Kütting M; Sellers S; Kirsten A; Marx P; Kim I; Cheung A; Leipsic J; Søndergaard L; Toggweiler S; Wood DA; Webb JG; Sathananthan J
    Cardiovasc Eng Technol; 2022 Dec; 13(6):930-938. PubMed ID: 35505271
    [TBL] [Abstract][Full Text] [Related]  

  • 14. How Can We Help a Patient With a Small Failing Bioprosthesis?: An In Vitro Case Study.
    Midha PA; Raghav V; Condado JF; Arjunon S; Uceda DE; Lerakis S; Thourani VH; Babaliaros V; Yoganathan AP
    JACC Cardiovasc Interv; 2015 Dec; 8(15):2026-2033. PubMed ID: 26627992
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Impact of different valve-in-valve positions on the hydrodynamic performance of the newest-generation self-expanding transcatheter heart valve.
    Sadat N; Bruhn D; Scharfschwerdt M; Schaller T; Aboud A; Saisho H; Eitel I; Ensminger S; Fujita B
    Eur J Cardiothorac Surg; 2022 Oct; 62(5):. PubMed ID: 35333318
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Hemodynamic Performance of Endovascular Valves as Valve-in-Valve in Small Stented Bioprosthesis.
    Kuehnel RU; Hartrumpf M; Erb M; Albes JM
    Thorac Cardiovasc Surg; 2017 Apr; 65(3):225-230. PubMed ID: 27517167
    [No Abstract]   [Full Text] [Related]  

  • 17. Valve Type, Size, and Deployment Location Affect Hemodynamics in an In Vitro Valve-in-Valve Model.
    Midha PA; Raghav V; Condado JF; Okafor IU; Lerakis S; Thourani VH; Babaliaros V; Yoganathan AP
    JACC Cardiovasc Interv; 2016 Aug; 9(15):1618-28. PubMed ID: 27491613
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Deformation of Transcatheter Heart Valve Following Valve-in-Valve Transcatheter Aortic Valve Replacement: Implications for Hemodynamics.
    Fukui M; Sorajja P; Cavalcante JL; Thao KR; Okada A; Sato H; Wang C; Koike H; Hamid N; Enriquez-Sarano M; Lesser JR; Bapat VN
    JACC Cardiovasc Interv; 2023 Mar; 16(5):515-526. PubMed ID: 36922036
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of two self-expanding transcatheter heart valves for degenerated surgical bioprostheses: the AVENGER multicentre registry.
    Kim WK; Seiffert M; Rück A; Leistner DM; Dreger H; Wienemann H; Adam M; Möllmann H; Blumenstein J; Eckel C; Buono A; Maffeo D; Messina A; Holzamer A; Sossalla S; Costa G; Barbanti M; Motta S; Tamburino C; von der Heide I; Glasmacher J; Sherif M; Seppelt P; Fichtlscherer S; Walther T; Castriota F; Nerla R; Frerker C; Schmidt T; Wolf A; Adamaszek MM; Giannini F; Vanhaverbeke M; Van de Walle S; Stammen F; Toggweiler S; Brunner S; Mangieri A; Gitto M; Kaleschke G; Ninios V; Ninios I; Hübner J; Xhepa E; Renker M; Charitos EI; Joner M; Rheude T
    EuroIntervention; 2024 Mar; 20(6):e363-e375. PubMed ID: 38506737
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Coronary Access After Transcatheter Aortic Valve Replacement With Commissural Alignment: The ALIGN-ACCESS Study.
    Tarantini G; Nai Fovino L; Scotti A; Massussi M; Cardaioli F; Rodinò G; Benedetti A; Boiago M; Matsuda Y; Continisio S; Montonati C; Cacciavillani L; Pavei A; Masiero G; Napodano M; Fraccaro C; Fabris T; Iliceto S
    Circ Cardiovasc Interv; 2022 Feb; 15(2):e011045. PubMed ID: 35167332
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.